Skip to content
DraconiticResearch
Search Sources API
197,785 studies31 sourcesUpdated 44 min ago
Peer-reviewedCC BY 4.0Radiation Measurements

Geant4 modeling and experimental validation of a BGO-based indirect X-ray imaging system: Toward optimized performance

Abstract

This work investigates the performance of an indirect X-ray imaging system based on a scintillator detector. We develop and validate a Geant4-based simulation tool that models the X-ray interactions, energy deposition, and the generation and transport of scintillation photons within a Bismuth Germinate Oxide (BGO) scintillator. The model is validated by comparing simulated and experimentally measured Point Spread Functions (PSFs) using a laboratory X-ray imaging system, showing excellent agreement. To illustrate its capability, the validated model is then used to investigate the influence of key parameters such as scintillator thickness, surface reflectivity, and source cone angle on imaging performance. These results highlight the trade-offs between detection efficiency, contrast, and spatial resolution, providing valuable guidelines for the optimization of scintillator-based X-ray imaging systems.

Related

  1. Equivalent linearization modeling and experimental validation of natural frequency and vibration isolation performance in metal braided hoses
    Dacheng Huang, Yue Liu, Dongqin Li +1
    PLOS OnePeer-reviewedCC BY 4.0Full textMaterials & polymersAlgebra & number theoryPLOSPMC
  2. Performance modeling and outdoor experimental investigation of a multi-format-compatible FSO system under atmospheric turbulence
    Dongsheng Tian, Peng Zhang, He Zhao +9
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  3. Electro-thermal PEMFC system modeling with experimental validation on 6 kW liquid-cooled stack
    Rafika Ben Haj Slama, Mouhamad Ankouni, Mohamed Moussa El Idi +2
    Engineering Research ExpressPeer-reviewedCC BYDynamical systemsFluid dynamicsHAL
  4. Response-function-optimized phase field modeling of solute trapping and solute drag in rapid alloy solidification
    Joni Kaipainen, Tatu Pinomaa, Nikolas Provatas
    arXivPreprintCC BY 4.0Full textComputational physicsCondensed matterarXiv
  5. Disorder-tuned soliton nucleation for vibrational energy harvesting in discrete nonlinear lattices. II. Proof of concept and experimental validation with a piezomagnetic metastructure
    Arthur Barbosa, Najib Kacem, Noureddine Bouhaddi
    Physical Review AppliedPeer-reviewedHAL deposit licenceFull textGeneral physicsHAL
BibTeX
@article{zghari2026geant4,
  title = {{Geant4 modeling and experimental validation of a BGO-based indirect X-ray imaging system: Toward optimized performance}},
  author = {Ismail Zghari and Amélie Jarnac and Olivier Durand and Johann Plagnard and Anthony Touron and Adrien Stolidi},
  journal = {Radiation Measurements},
  year = {2026},
  month = sep,
  doi = {10.1016/j.radmeas.2026.107803},
  url = {https://hal.science/hal-05747421v1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Geant4 modeling and experimental validation of a BGO-based indirect X-ray imaging system: Toward optimized performance
AU  - Ismail Zghari
AU  - Amélie Jarnac
AU  - Olivier Durand
AU  - Johann Plagnard
AU  - Anthony Touron
AU  - Adrien Stolidi
PY  - 2026
DA  - 2026/09/11
JO  - Radiation Measurements
DO  - 10.1016/j.radmeas.2026.107803
UR  - https://hal.science/hal-05747421v1
AB  - This work investigates the performance of an indirect X-ray imaging system based on a scintillator detector. We develop and validate a Geant4-based simulation tool that models the X-ray interactions, energy deposition, and the generation and transport of scintillation photons within a Bismuth Germinate Oxide (BGO) scintillator. The model is validated by comparing simulated and experimentally measured Point Spread Functions (PSFs) using a laboratory X-ray imaging system, showing excellent agreement. To illustrate its capability, the validated model is then used to investigate the influence of key parameters such as scintillator thickness, surface reflectivity, and source cone angle on imaging performance. These results highlight the trade-offs between detection efficiency, contrast, and spatial resolution, providing valuable guidelines for the optimization of scintillator-based X-ray imaging systems.
SN  - 1350-4487
ER  -