Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BY-NCJournal of orthopaedic case reports

Positioning and Traction Application Technique in Patient with Below Knee Amputation Using the Patients Own Prosthesis for Intertrochanteric Femur Fracture Fixation Surgery: A Case Report with Review of Literature.

  1. 1Department of Orthopaedics, Topiwala National Medical College and BYL Nair Charitable Hospital, Mumbai, Maharashtra, India.

Abstract

Surgical fixation of an intertrochanteric femur fracture in a patient with a below-knee amputation (BKA) is a challenging scenario for the orthopedic surgeon. Applying traction to reduce the fracture and maintaining it until definitive fixation is done with an implant is difficult, because the shortened limb cannot be secured to the foot attachment of a standard fracture table. Reported techniques are either invasive, requiring pins or wires, or need additional equipment. We describe a non-invasive alternative and discuss the various techniques available to address this problem. A 69-year-old woman with a right BKA presented with right hip pain and inability to bear weight following a fall at home. Before injury, she was independently ambulatory using a prosthesis. The stump was healthy and well healed. Radiographs revealed an intertrochanteric femur fracture with varus angulation. Closed reduction and internal fixation using a proximal femoral nail was planned. The prosthesis was secured to the stump using its velcro straps, additional bandages, and adhesive tapes and attached to the fracture table in the routine manner. Gradual traction was applied with internal rotation of the foot, and reduction was confirmed fluoroscopically. Fixation was performed using an 11 × 240 mm PFN with a 135° neck-shaft angle. Post-operative radiographs showed satisfactory alignment and stable fixation. She mobilized non-weight-bearing with a walker on post-operative day 1 and resumed full weight-bearing using the prosthesis at one month. Six-month follow-up demonstrated satisfactory radiological and functional outcomes. Using the patient's own BK prosthesis for positioning, traction, and rotational control effectively achieved and maintained the lower limb traction required during surgery. It allowed satisfactory reduction and stable fixation while avoiding invasive procedures or soft-tissue complications, and is simple, available, and cost-effective because it relies on a device the patient already uses. It adds a non-invasive option to the reduction methods available for hip fractures in amputees.

Related

  1. Prosthesis embodiment predicts reduced amputation salience as reflected in dreams
    Robin Bekrater-Bodmann
    Scientific ReportsPeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefDOAJ
  2. Tibial Post Fracture in a Posterior-Stabilized Knee Prosthesis: A Case Report and Review of the Literature
    César Abraham Ávila Lozano, César Alejandro Jiménez-Aroche, Jacobo Kerbel Sutton +4
    The American Journal of Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaPMC
  3. Application Value and Cognitive Challenges of PET/CT in the Diagnosis and Treatment of Visceral Leishmaniasis: A Retrospective Single-Center Case Series and Literature Review
    Boyu Zhang, Yu Zhang, Yaqin Wu +5
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Clinical application of Xianfang Huoming decoction in hidradenitis suppurativa: a three-case series and literature review
    Zixi Wang, Xuling Wu, Hongliu Zhu +5
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  5. Explainable machine learning for preoperative prediction of acute kidney injury after intertrochanteric fracture surgery in older adults
    Weizhang Lin, Ximing Lin, Hongpeng Gao
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{ranjankar2026positioning,
  title = {{Positioning and Traction Application Technique in Patient with Below Knee Amputation Using the Patients Own Prosthesis for Intertrochanteric Femur Fracture Fixation Surgery: A Case Report with Review of Literature.}},
  author = {Mangesh C Ranjankar and Akshay Pawar and Pratik Thorat},
  journal = {Journal of orthopaedic case reports},
  year = {2026},
  month = nov,
  doi = {10.13107/jocr.2026.v16.i11.8424},
  url = {https://europepmc.org/article/MED/42996983},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Positioning and Traction Application Technique in Patient with Below Knee Amputation Using the Patients Own Prosthesis for Intertrochanteric Femur Fracture Fixation Surgery: A Case Report with Review of Literature.
AU  - Mangesh C Ranjankar
AU  - Akshay Pawar
AU  - Pratik Thorat
PY  - 2026
DA  - 2026/11/01
JO  - Journal of orthopaedic case reports
DO  - 10.13107/jocr.2026.v16.i11.8424
UR  - https://europepmc.org/article/MED/42996983
AB  - Surgical fixation of an intertrochanteric femur fracture in a patient with a below-knee amputation (BKA) is a challenging scenario for the orthopedic surgeon. Applying traction to reduce the fracture and maintaining it until definitive fixation is done with an implant is difficult, because the shortened limb cannot be secured to the foot attachment of a standard fracture table. Reported techniques are either invasive, requiring pins or wires, or need additional equipment. We describe a non-invasive alternative and discuss the various techniques available to address this problem. A 69-year-old woman with a right BKA presented with right hip pain and inability to bear weight following a fall at home. Before injury, she was independently ambulatory using a prosthesis. The stump was healthy and well healed. Radiographs revealed an intertrochanteric femur fracture with varus angulation. Closed reduction and internal fixation using a proximal femoral nail was planned. The prosthesis was secured to the stump using its velcro straps, additional bandages, and adhesive tapes and attached to the fracture table in the routine manner. Gradual traction was applied with internal rotation of the foot, and reduction was confirmed fluoroscopically. Fixation was performed using an 11 × 240 mm PFN with a 135° neck-shaft angle. Post-operative radiographs showed satisfactory alignment and stable fixation. She mobilized non-weight-bearing with a walker on post-operative day 1 and resumed full weight-bearing using the prosthesis at one month. Six-month follow-up demonstrated satisfactory radiological and functional outcomes. Using the patient's own BK prosthesis for positioning, traction, and rotational control effectively achieved and maintained the lower limb traction required during surgery. It allowed satisfactory reduction and stable fixation while avoiding invasive procedures or soft-tissue complications, and is simple, available, and cost-effective because it relies on a device the patient already uses. It adds a non-invasive option to the reduction methods available for hip fractures in amputees.
SN  - 2250-0685
SN  - 2321-3817
ER  -