Tibial Post Fracture in a Posterior-Stabilized Knee Prosthesis: A Case Report and Review of the Literature
- 1ABC Medical Centre, Sports Medicine, Adult Hip & Knee Reconstruction, México City, México
Abstract
Patient: Male, 92-year-old
Final Diagnosis: Fracture of tibial post
Symptoms: Pain
Clinical Procedure: —
Specialty: Orthopedics and Traumatology
Objective: Unusual clinical course
Background: Tibial post fracture is an uncommon but likely underrecognized complication of posterior-stabilized (PS) total knee arthroplasty (TKA) that often remains undiagnosed because conventional radiographs may be unrevealing. We report a late tibial post fracture in a previously well-functioning PS TKA, highlighting the role of dynamic fluoroscopy in raising preoperative suspicion and the successful use of isolated polyethylene insert exchange in a carefully selected patient.
Case Report: A 92-year-old man presented with acute mechanical pain, recurrent clicking, and subjective instability 16 years after primary PS TKA following a low-energy flexion-rotation movement. Plain radiographs showed no evidence of periprosthetic fracture, component loosening, or implant failure. Dynamic fluoroscopy during flexion, which reproduced the patient’s symptoms, demonstrated abnormal anterior translation of the femoral component relative to the tibial insert during knee flexion, raising suspicion of cam-post mechanism failure. Revision surgery confirmed a fracture of the polyethylene tibial post with chronic wear at its base; the metallic components remained well fixed, without gross malposition. Isolated polyethylene insert exchange with a thicker insert restored intraoperative stability. At 4.5 months postoperatively, the patient demonstrated complete resolution of mechanical symptoms, with full extension, 100° to 110° of flexion, and preserved varus-valgus and anteroposterior stability.
Conclusions: This case illustrates how dynamic fluoroscopy may raise preoperative suspicion of tibial post fracture in selected patients with symptomatic late PS TKA and inconclusive conventional radiographs. In our patient, isolated polyethylene insert exchange was effective after confirmation of preserved component fixation, alignment, and overall stability, supporting its use in appropriately selected cases.
Related
- Early Post-operative Fracture of Titanium Cementless Tibial Baseplate: Case Report and Review of the Literature.
- Positioning and Traction Application Technique in Patient with Below Knee Amputation Using the Patients Own Prosthesis for Intertrochanteric Femur Fracture Fixation Surgery: A Case Report with Review of Literature.
- Unsupervised machine learning identifies two distinct posterior tibial slope clusters largely independent of Coronal Plane Alignment of the Knee in osteoarthritic knees
- No significant change in tibial torsion despite hinge fracture after high tibial osteotomy using patient‐specific instruments
- Disparities in Tibial Fracture Care for Patients With Limited English Proficiency
BibTeX
@article{lozano2026tibial,
title = {{Tibial Post Fracture in a Posterior-Stabilized Knee Prosthesis: A Case Report and Review of the Literature}},
author = {César Abraham Ávila Lozano and César Alejandro Jiménez-Aroche and Jacobo Kerbel Sutton and Iturbide Andrés Ponce de León Sandoval and José Eduardo Miranda Mayén and Ady Haim Kahana-Rojkind and Juan José Gómez Amezcua},
journal = {The American Journal of Case Reports},
year = {2026},
month = oct,
doi = {10.12659/ajcr.954794},
url = {https://doi.org/10.12659/ajcr.954794},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Tibial Post Fracture in a Posterior-Stabilized Knee Prosthesis: A Case Report and Review of the Literature
AU - César Abraham Ávila Lozano
AU - César Alejandro Jiménez-Aroche
AU - Jacobo Kerbel Sutton
AU - Iturbide Andrés Ponce de León Sandoval
AU - José Eduardo Miranda Mayén
AU - Ady Haim Kahana-Rojkind
AU - Juan José Gómez Amezcua
PY - 2026
DA - 2026/10/30
JO - The American Journal of Case Reports
DO - 10.12659/ajcr.954794
UR - https://doi.org/10.12659/ajcr.954794
AB - Patient: Male, 92-year-old Final Diagnosis: Fracture of tibial post Symptoms: Pain Clinical Procedure: — Specialty: Orthopedics and Traumatology Objective: Unusual clinical course Background: Tibial post fracture is an uncommon but likely underrecognized complication of posterior-stabilized (PS) total knee arthroplasty (TKA) that often remains undiagnosed because conventional radiographs may be unrevealing. We report a late tibial post fracture in a previously well-functioning PS TKA, highlighting the role of dynamic fluoroscopy in raising preoperative suspicion and the successful use of isolated polyethylene insert exchange in a carefully selected patient. Case Report: A 92-year-old man presented with acute mechanical pain, recurrent clicking, and subjective instability 16 years after primary PS TKA following a low-energy flexion-rotation movement. Plain radiographs showed no evidence of periprosthetic fracture, component loosening, or implant failure. Dynamic fluoroscopy during flexion, which reproduced the patient’s symptoms, demonstrated abnormal anterior translation of the femoral component relative to the tibial insert during knee flexion, raising suspicion of cam-post mechanism failure. Revision surgery confirmed a fracture of the polyethylene tibial post with chronic wear at its base; the metallic components remained well fixed, without gross malposition. Isolated polyethylene insert exchange with a thicker insert restored intraoperative stability. At 4.5 months postoperatively, the patient demonstrated complete resolution of mechanical symptoms, with full extension, 100° to 110° of flexion, and preserved varus-valgus and anteroposterior stability. Conclusions: This case illustrates how dynamic fluoroscopy may raise preoperative suspicion of tibial post fracture in selected patients with symptomatic late PS TKA and inconclusive conventional radiographs. In our patient, isolated polyethylene insert exchange was effective after confirmation of preserved component fixation, alignment, and overall stability, supporting its use in appropriately selected cases.
SN - 1941-5923
ER -