Optimizing assay conditions for gaussia luciferase
- 1University of Copenhagen
Abstract
Gaussia luciferase (GLuc) is a widely used reporter enzyme due to its small size and exceptionally intense light output. However, its characteristic 'flash' properties have made accurate determination of enzyme activity sensitive to minute variations in the experimental setup, which is the likely cause of many inconsistent and contradictory findings in the literature. The intrinsic instability of the substrate, coelenterazine, adds to these complications. Furthermore, at the high dilutions commonly required to measure this exceptionally active enzyme, the signal often deviates from the expected linear relationship between activity and concentration due to adsorption. In this study, we systematically investigated the critical experimental parameters that affect activity measurements using a 96-well plate reader with an automated injection system. To illustrate experimental issues, we applied our analysis to measurements of GLuc and GLuc variants with widely different levels of activity and decay rates as well as with different substrates. We demonstrate that variations in 1) latency between substrate injection and measurement, 2) enzyme dilution and adhesion, and 3) substrate handling and degradation can lead to inconsistent values for specific activity. Based on this, we suggest a framework for optimizing GLuc assay conditions for reproducibility.
Related
- Shedding light on Gaussia Luciferase conformational space using multi-conformation enhanced sampling simulation
- Optimizing environmental conditions for PALM imaging of the nuclear pore complex labeled with the photoconvertible fluorescent protein mEos4b.
- Condition aware learning enables robust prediction of oligonucleotide melting behavior across diverse chemistries and assay conditions
- Quantitative Bioluminescent Imaging of AHR Activity Using a Thermostable Variant of the Fungal Luciferase nnLuz
- ClpB-mediated modulation of GroEL-bound luciferase and subsequent refolding by DnaK chaperone system
BibTeX
@misc{vinther2026optimizing,
title = {{Optimizing assay conditions for gaussia luciferase}},
author = {S. K. Vinther and J. R. Winther},
howpublished = {bioRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.11.765880},
url = {https://www.biorxiv.org/content/10.64898/2026.11.11.765880v1},
note = {CC BY-ND},
}
RIS
TY - UNPB
TI - Optimizing assay conditions for gaussia luciferase
AU - S. K. Vinther
AU - J. R. Winther
PY - 2026
DA - 2026/11/11
PB - bioRxiv
DO - 10.64898/2026.11.11.765880
UR - https://www.biorxiv.org/content/10.64898/2026.11.11.765880v1
AB - Gaussia luciferase (GLuc) is a widely used reporter enzyme due to its small size and exceptionally intense light output. However, its characteristic 'flash' properties have made accurate determination of enzyme activity sensitive to minute variations in the experimental setup, which is the likely cause of many inconsistent and contradictory findings in the literature. The intrinsic instability of the substrate, coelenterazine, adds to these complications. Furthermore, at the high dilutions commonly required to measure this exceptionally active enzyme, the signal often deviates from the expected linear relationship between activity and concentration due to adsorption. In this study, we systematically investigated the critical experimental parameters that affect activity measurements using a 96-well plate reader with an automated injection system. To illustrate experimental issues, we applied our analysis to measurements of GLuc and GLuc variants with widely different levels of activity and decay rates as well as with different substrates. We demonstrate that variations in 1) latency between substrate injection and measurement, 2) enzyme dilution and adhesion, and 3) substrate handling and degradation can lead to inconsistent values for specific activity. Based on this, we suggest a framework for optimizing GLuc assay conditions for reproducibility.
ER -