Challenges in measuring serum calprotectin in autoinflammation: a comparative study of different immunoassays
- 1Department of Pediatric Rheumatology and Immunology, University Children’s Hospital Muenster, Albert-Schweitzer-Campus 1, W30, Muenster, 48161 Germany
- 2Central Laboratory, University Hospital Muenster, Muenster, Germany
- 3University Institute of Clinical Chemistry, University Hospital of Bern, Bern, Switzerland
Abstract
Background: Serum calprotectin (S100A8/A9 complex) is increasingly used in the clinical evaluation of autoinflammatory diseases (AID). However, systematic comparisons of commercially available assays remain limited. This study aimed to assess comparability, and clinical applicability of commercial calprotectin assays to support standardized biomarker-guided diagnostics.
Methods: Serum samples from 40 individuals—systemic juvenile idiopathic arthritis (sJIA, n = 10), adult-onset Still’s disease (AOSD, n = 10), familial Mediterranean fever (FMF, n = 10), PAPA syndrome (n = 2), infections (n = 5), leukemia (n = 3), and healthy pediatric controls (n = 10)—were analyzed. Calprotectin concentrations were measured using four ELISAs (BÜHLMANN, R&D Systems, BioLegend, BMA), two PETIAs (sCAL turbo, GCAL), and one CLIA (QuantaFlash) and compared with a BÜHLMANN ELISA reference. ELISA assays were measured with a secondary 10-fold dilution, while PETIA and CLIA assays were performed on automated platforms with reflex dilution. Spiking experiments were conducted to evaluate recovery.
Results: All assays except BMA (r = 0.52) showed strong correlation with the reference (r ≥ 0.96). Median values in healthy controls varied markedly (0.29–3.22 µg/mL), with inter-assay differences exceeding one log scale. Several assays underestimated very high concentrations (> 50 µg/mL), likely due to Hook effects, and upper detection limits differed substantially. Spike recovery ranged from 79 to 268%, with the most consistent results observed for sCAL turbo.
Conclusions: Commercial assays reliably quantify serum calprotectin in the normal to moderately elevated range but are not interchangeable. Variability in detection limits and susceptibility to Hook effects may lead to underestimation in severe inflammation. Assay-specific reference ranges and additional dilution steps are recommended, particularly when extreme elevations are suspected.
Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s40348-026-00267-8.
Related
- A novel PAAND-like MEFV variant in cis with an FMF mutation drives severe neonatal autoinflammation.
- Investigation of Cu(II) Binding by Human Calprotectin Reveals an Unusual Fluxional Coordination Environment
- Challenges and progress in RNA velocity: Comparative analysis across multiple biological contexts
- Calprotectin – clinical and diagnostic value in rheumatoid arthritis
- Benchmarking batch-effect correction in clinical bead-based multiplex immunoassays: a framework and web tool for cytokine and soluble immune checkpoint data
BibTeX
@article{wittkowski2026challenges,
title = {{Challenges in measuring serum calprotectin in autoinflammation: a comparative study of different immunoassays}},
author = {Helmut Wittkowski and Carolin Park and Melanie Saers and Sabrina Fühner and Susanne Schleifenbaum and Claas Hinze and Manfred Fobker and Andrea Karolin and Michael P. Horn and Bernhard Schlüter and Dirk Foell},
journal = {Molecular and Cellular Pediatrics},
year = {2026},
month = nov,
doi = {10.1186/s40348-026-00267-8},
url = {https://doi.org/10.1186/s40348-026-00267-8},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Challenges in measuring serum calprotectin in autoinflammation: a comparative study of different immunoassays
AU - Helmut Wittkowski
AU - Carolin Park
AU - Melanie Saers
AU - Sabrina Fühner
AU - Susanne Schleifenbaum
AU - Claas Hinze
AU - Manfred Fobker
AU - Andrea Karolin
AU - Michael P. Horn
AU - Bernhard Schlüter
AU - Dirk Foell
PY - 2026
DA - 2026/11/10
JO - Molecular and Cellular Pediatrics
DO - 10.1186/s40348-026-00267-8
UR - https://doi.org/10.1186/s40348-026-00267-8
AB - Background: Serum calprotectin (S100A8/A9 complex) is increasingly used in the clinical evaluation of autoinflammatory diseases (AID). However, systematic comparisons of commercially available assays remain limited. This study aimed to assess comparability, and clinical applicability of commercial calprotectin assays to support standardized biomarker-guided diagnostics. Methods: Serum samples from 40 individuals—systemic juvenile idiopathic arthritis (sJIA, n = 10), adult-onset Still’s disease (AOSD, n = 10), familial Mediterranean fever (FMF, n = 10), PAPA syndrome (n = 2), infections (n = 5), leukemia (n = 3), and healthy pediatric controls (n = 10)—were analyzed. Calprotectin concentrations were measured using four ELISAs (BÜHLMANN, R&D Systems, BioLegend, BMA), two PETIAs (sCAL turbo, GCAL), and one CLIA (QuantaFlash) and compared with a BÜHLMANN ELISA reference. ELISA assays were measured with a secondary 10-fold dilution, while PETIA and CLIA assays were performed on automated platforms with reflex dilution. Spiking experiments were conducted to evaluate recovery. Results: All assays except BMA (r = 0.52) showed strong correlation with the reference (r ≥ 0.96). Median values in healthy controls varied markedly (0.29–3.22 µg/mL), with inter-assay differences exceeding one log scale. Several assays underestimated very high concentrations (> 50 µg/mL), likely due to Hook effects, and upper detection limits differed substantially. Spike recovery ranged from 79 to 268%, with the most consistent results observed for sCAL turbo. Conclusions: Commercial assays reliably quantify serum calprotectin in the normal to moderately elevated range but are not interchangeable. Variability in detection limits and susceptibility to Hook effects may lead to underestimation in severe inflammation. Assay-specific reference ranges and additional dilution steps are recommended, particularly when extreme elevations are suspected. Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s40348-026-00267-8.
SN - 2194-7791
ER -