A Review of Linear Stapled‐Sutured Intrathoracic Oesophago‐Gastric Anastomosis by a Single Surgeon Over Three Decades
4 affiliations
- 1Department of Upper Gastrointestinal and Hepato‐Pancreato‐Biliary Surgery Box Hill Hospital, Eastern Health Melbourne Australia
- 2Epworth Eastern Hospital Box Hill Australia
- 3Monash University, Eastern Health Campus Box Hill Australia
- 4St Vincent's Hospital Melbourne Australia
Abstract
This paper describes the technique of performing an intrathoracic linear stapled/sutured anastomosis between the oesophagus and gastric conduit. It analyses the outcome from a single surgeon working at two co‐located hospitals.
Method: A retrospective review of prospectively collected data was performed. The study includes 188 operations performed by a single surgeon (ASH) between 1998 and 2025. The mortality and morbidity for the series are analyzed and the technique used is described.
Results: The anastomotic leak rate for the 188 patients was found to be 3.2% with an inpatient mortality of 0.5% at 30 days and a mortality of 1.1% at 90 days. The overall stricture rate requiring dilatation was approximately 4.3%. These results from a low volume center compare favorably with international data.
Conclusion: The linear stapled/sutured anastomotic technique is associated with a low anastomotic leak rate and mortality. The stricture rate is also low when compared to other series of oesophagectomy.
Related
- Completely endoscopic reversal of vertical banded gastroplasty using magnetic compression gastro-gastric anastomosis.
- Cost-effectiveness analysis of FundoRing versus standard one-anastomosis gastric bypass: up to 3-year results of a randomized controlled trial
- NUTRITIONAL OUTCOMES AFTER ONE ANASTOMOSIS GASTRIC BYPASS VERSUS ROUX-EN-Y GASTRIC BYPASS: A ONE-YEAR COMPARATIVE STUDY Desfechos nutricionais após derivação gástrica em Y-de-Roux versus derivação gastrojejunal com anastomose única: estudo comparativo de um ano
- The Therapeutic Effects of 4-Aminopyridine Administration via Phonophoresis on Sutured Postoperative Wounds: A Histopathological, Immunohistochemical, Molecular, and Morphometric Study
- Delayed intrathoracic closed-loop small bowel obstruction due to iatrogenic diaphragmatic hernia two years after subxiphoid pericardial window: a case report.
BibTeX
@article{anderson2026review,
title = {{A Review of Linear Stapled‐Sutured Intrathoracic Oesophago‐Gastric Anastomosis by a Single Surgeon Over Three Decades}},
author = {Matilda Anderson and Enoch Wong and Jan Goonawardena and Peter Bird and Richard Cade and Akhtar H. Sayed Hassen},
journal = {Anz Journal of Surgery},
year = {2026},
month = jun,
doi = {10.1111/ans.70801},
url = {https://doi.org/10.1111/ans.70801},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - A Review of Linear Stapled‐Sutured Intrathoracic Oesophago‐Gastric Anastomosis by a Single Surgeon Over Three Decades
AU - Matilda Anderson
AU - Enoch Wong
AU - Jan Goonawardena
AU - Peter Bird
AU - Richard Cade
AU - Akhtar H. Sayed Hassen
PY - 2026
DA - 2026/06/16
JO - Anz Journal of Surgery
DO - 10.1111/ans.70801
UR - https://doi.org/10.1111/ans.70801
AB - This paper describes the technique of performing an intrathoracic linear stapled/sutured anastomosis between the oesophagus and gastric conduit. It analyses the outcome from a single surgeon working at two co‐located hospitals. Method: A retrospective review of prospectively collected data was performed. The study includes 188 operations performed by a single surgeon (ASH) between 1998 and 2025. The mortality and morbidity for the series are analyzed and the technique used is described. Results: The anastomotic leak rate for the 188 patients was found to be 3.2% with an inpatient mortality of 0.5% at 30 days and a mortality of 1.1% at 90 days. The overall stricture rate requiring dilatation was approximately 4.3%. These results from a low volume center compare favorably with international data. Conclusion: The linear stapled/sutured anastomotic technique is associated with a low anastomotic leak rate and mortality. The stricture rate is also low when compared to other series of oesophagectomy.
SN - 1445-1433
SN - 1445-2197
ER -