Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 12 min ago
PreprintCC BY-NCbioRxiv

NPlasmid-seq: Cas9-encoded terminal signatures enable molecule-level nanopore quality control of vector and IVT-template plasmids

  1. 1Institute of Hematology & Blood Diseases Hospital

Abstract

Consensus-based plasmid quality control can overlook structural heterogeneity within a preparation. We developed NPlasmid-seq, a Cas9-guided nanopore workflow that encodes sample identity through paired terminal signatures generated at predefined backbone positions, without sample-specific oligonucleotide barcodes. We cleavage-validated 24 sgRNAs. In five representative assigned read bins, each bin showed its strongest sequence agreement with its cognate reference. Contaminant detection was evaluated with a single class-specific classifier applied both to computational read mixtures and to physical DNA mixtures, placing the two designs on a common scale. In computational read mixtures of 5,000 reads, a contaminant was detected in all 20 independent subsamples at each of 0.2%, 0.5%, 1% and 5% abundance and in 13 of 20 subsamples at 0.1%; precision was 1.000 in all 100 subsamples, with no false-positive calls among 493,200 reads from the declared target plasmid. In physical DNA mixtures carried through cleavage, pooled library preparation and sequencing, a contaminant was detected in all six samples prepared at 0.5 mol% input and all six at 1 mol%. Observed read fractions did not distinguish the 0.5 and 1 mol% input levels. Instead, they differed systematically by 4.0-fold between preparation pools, a larger effect than the difference between the two input levels. We therefore interpret the workflow as a detector, not a quantifier, of sub-percent contamination. Read-level analysis identified a recurrent 93-bp deletion in 61.7% of reads from a preparation that had passed consensus-based quality control. Sanger genotyping of 24 colonies identified deletion-type profiles in 10 colonies and intact-type profiles in three. The remaining 11 colonies showed double peaks at the diagnostic locus, consistent with coexistence of both sequence forms within individual clones. In in vitro transcription template plasmids, longer poly(A) tracts were associated with higher multimeric-read fractions. Across ten matched A90 culture pairs, propagation at 30 degree reduced these fractions relative to 37 degree (paired t-test, P = 0.0098). These measurements describe recovered read populations, not absolute molecular abundances. NPlasmid-seq therefore complements consensus validation by revealing sequence and structural heterogeneity within a preparation and by identifying a culture condition associated with a lower multimeric-read fraction.

Related

  1. Predicted condensation-related signatures localize to two C-terminal regions of the prion protein across cervid PRNP variants associated with chronic wasting disease
    G. W. Dayhoff, L. Dorosh, H. Wille +2
    bioRxivPreprintCC BY-NCFull textBioinformatics & computational biologybioRxiv
  2. Single-cell RNA sequencing of terminal ileal biopsies identifies signatures of Crohn’s disease pathogenesis
    Monika Krzak, Tobi Alegbe, D. Leland Taylor +35
    Nature GeneticsPeer-reviewedCC BYFull text28 citedGenetics & genomicsGeneral medicineOpenAlex
  3. Archaerhodopsin 3 is an ideal template for the engineering of highly fluorescent optogenetic reporters
    Krystyna Herasymenko, Danushka Walisinghe, Masae Konno +6
    Chemical SciencePeer-reviewedCC BY9 citedNeuroscienceHAL
  4. Kinetics of template-directed multistate copolymerization
    Pierre Gaspard
    arXivPreprintarXiv licenceFull textBioinformatics & computational biologyStatistical & nonlinear physicsarXiv
  5. Integrative Nanopore and Illumina sequencing reveals age-associated tRNA modification and CCA-tail dynamics in yeast
    K. M. Brazell, C. Prevost, N. Zawrotna +4
    bioRxivPreprintAll rights reservedFull textGenetics & genomicsbioRxiv
BibTeX
@misc{xu2026nplasmidseq,
  title = {{NPlasmid-seq: Cas9-encoded terminal signatures enable molecule-level nanopore quality control of vector and IVT-template plasmids}},
  author = {Y. Xu and W. Wen and D. Sun and Y.-X. Yin and X.-Y. Ma and J.-X. Ren and S.-M. Zhang and J.-Q. Chang and S.-C. Pang and S.-D. Wang and X.-B. Zhang and J.-P. Zhang},
  howpublished = {bioRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.02.763549},
  url = {https://www.biorxiv.org/content/10.64898/2026.11.02.763549v1},
  note = {CC BY-NC},
}
RIS
TY  - UNPB
TI  - NPlasmid-seq: Cas9-encoded terminal signatures enable molecule-level nanopore quality control of vector and IVT-template plasmids
AU  - Y. Xu
AU  - W. Wen
AU  - D. Sun
AU  - Y.-X. Yin
AU  - X.-Y. Ma
AU  - J.-X. Ren
AU  - S.-M. Zhang
AU  - J.-Q. Chang
AU  - S.-C. Pang
AU  - S.-D. Wang
AU  - X.-B. Zhang
AU  - J.-P. Zhang
PY  - 2026
DA  - 2026/11/02
PB  - bioRxiv
DO  - 10.64898/2026.11.02.763549
UR  - https://www.biorxiv.org/content/10.64898/2026.11.02.763549v1
AB  - Consensus-based plasmid quality control can overlook structural heterogeneity within a preparation. We developed NPlasmid-seq, a Cas9-guided nanopore workflow that encodes sample identity through paired terminal signatures generated at predefined backbone positions, without sample-specific oligonucleotide barcodes. We cleavage-validated 24 sgRNAs. In five representative assigned read bins, each bin showed its strongest sequence agreement with its cognate reference. Contaminant detection was evaluated with a single class-specific classifier applied both to computational read mixtures and to physical DNA mixtures, placing the two designs on a common scale. In computational read mixtures of 5,000 reads, a contaminant was detected in all 20 independent subsamples at each of 0.2%, 0.5%, 1% and 5% abundance and in 13 of 20 subsamples at 0.1%; precision was 1.000 in all 100 subsamples, with no false-positive calls among 493,200 reads from the declared target plasmid. In physical DNA mixtures carried through cleavage, pooled library preparation and sequencing, a contaminant was detected in all six samples prepared at 0.5 mol% input and all six at 1 mol%. Observed read fractions did not distinguish the 0.5 and 1 mol% input levels. Instead, they differed systematically by 4.0-fold between preparation pools, a larger effect than the difference between the two input levels. We therefore interpret the workflow as a detector, not a quantifier, of sub-percent contamination. Read-level analysis identified a recurrent 93-bp deletion in 61.7% of reads from a preparation that had passed consensus-based quality control. Sanger genotyping of 24 colonies identified deletion-type profiles in 10 colonies and intact-type profiles in three. The remaining 11 colonies showed double peaks at the diagnostic locus, consistent with coexistence of both sequence forms within individual clones. In in vitro transcription template plasmids, longer poly(A) tracts were associated with higher multimeric-read fractions. Across ten matched A90 culture pairs, propagation at 30 degree reduced these fractions relative to 37 degree (paired t-test, P = 0.0098). These measurements describe recovered read populations, not absolute molecular abundances. NPlasmid-seq therefore complements consensus validation by revealing sequence and structural heterogeneity within a preparation and by identifying a culture condition associated with a lower multimeric-read fraction.
ER  -