Low-Intensity Continuous Ultrasound vs. Traditional Ultrasound: A Systematic Review and Descriptive Analysis on Past and Future Gold Standards for Deep-Tissue Diathermy in Clinical Medicine.

  1. 1Clinical Research Department, Orthopaedic Foundation, Stamford, CT 06905, USA.
  2. 2Research and Development Service, James A Haley Veterans Hospital, Tampa, FL 33612, USA.

Abstract

Background/objectives

The thermal effects of therapeutic ultrasound (US) have been utilized to promote musculoskeletal healing. However, the optimal combination of US parameters, while studied in the past, has yet to be updated with the advent of newer US modalities, including low-intensity continuous ultrasound (LICUS). The purpose of this study was to evaluate the effects of US frequency, intensity, and duration on changes in tissue temperature and to compare the thermal response between traditional US and LICUS.Methods

Following PRISMA guidelines, PubMed, Embase, and Web of Science were searched for in vivo human studies that reported temperature changes and used standard ultrasound parameters (1 or 3 MHz, 0.1-2.0 W/cm², aqueous gel). US frequency, intensity, duration, effective radiating area (ERA), body region, and total energy delivered at three depths (1 cm, 3 cm, and 5 cm) were extracted. The outcome of interest was change in tissue temperature (i.e., ultrasonic diathermy). A mathematical model was used to interpolate missing data. Three-way ANOVA and t-tests were used to compare outcomes.Results

Nineteen studies (384 participants) were included. The weighted mean total energy delivered was 6698.5 ± 6767.4 J and was significantly correlated with tissue temperature change across all depths (r = 0.544, p < 0.001). At 1, 3, and 5 cm depths, significant interactions were observed between ultrasound intensity and frequency and between intensity and treatment duration (all p ≤ 0.05). Higher intensities generally produced greater temperature increases during shorter treatments (≤10 min), whereas longer treatment durations (≥60 min) at low intensity produced the greatest temperature increases overall. Frequency-dependent effects were also observed, with greater temperature increases at 3 MHz compared with 1 MHz at several intensity levels. LICUS delivered significantly more total energy than traditional 3 MHz US (13,854.4 ± 8129.6 vs. 3546.5 ± 2096.0 Joules, p < 0.001) and produced significantly greater tissue temperature increases at all depths (p < 0.001).Conclusions

Changes in tissue temperature are strongly correlated with the total US energy delivered. While frequency, intensity, and duration play a significant role in thermal energy, LICUS over sustained periods delivers significantly greater cumulative energy and, subsequently, greater tissue temperature change compared to traditional US.

Related

  1. Target-dependent parameter-effect landscapes of low-intensity focused ultrasound neuromodulation in humans: a systematic review
    H. Jang, K. S. Meka, A. Yang +3
    medRxivPreprintAll rights reservedFull textNeurologymedRxiv
  2. Low-intensity pulsed ultrasound for erectile dysfunction: a systematic review and limited quantitative synthesis
    Yu Zhang, Zhi-Shen Li, Yu-Yun Wu +4
    Translational andrology and urologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  3. Urinary and Sexual Function Outcomes After Ultrasound-Guided High-Intensity Focused Ultrasound for Uterine Fibroids: Associations of Lower Urinary Tract Symptoms with Fibroid Location and Uterine Morphology
    Cheng-Yu Long, Cherng-Jye Jeng, Liang-Ying Ke
    BiomedicinesPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Characteristics of junior residents choosing alternative career pathways without entering traditional specialty residency programs: An exploratory descriptive study
    Koshi Ota, Kanna Ota
    SAGE Open MedicinePeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMCEurope PMC
  5. Efficacy and Safety of 1.5‐ and 3.0‐mm High‐Intensity Focused Ultrasound for Eyebrow Lifting in Korean Adults: A Prospective Randomized Split‐Face Study
    Kwang Ho Yoo, Hyewon Song, Yuhwa Choi
    Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)Peer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{wang2026lowintensity,
  title = {{Low-Intensity Continuous Ultrasound vs. Traditional Ultrasound: A Systematic Review and Descriptive Analysis on Past and Future Gold Standards for Deep-Tissue Diathermy in Clinical Medicine.}},
  author = {Samuel Wang and Aaditya Jain and Jemy M Delikat and Jude Delikat and Samuel Phillips and Stephanie Petterson},
  journal = {Medical sciences (Basel, Switzerland)},
  year = {2026},
  month = oct,
  doi = {10.3390/medsci14060631},
  url = {https://europepmc.org/article/MED/42930550},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Low-Intensity Continuous Ultrasound vs. Traditional Ultrasound: A Systematic Review and Descriptive Analysis on Past and Future Gold Standards for Deep-Tissue Diathermy in Clinical Medicine.
AU  - Samuel Wang
AU  - Aaditya Jain
AU  - Jemy M Delikat
AU  - Jude Delikat
AU  - Samuel Phillips
AU  - Stephanie Petterson
PY  - 2026
DA  - 2026/10/02
JO  - Medical sciences (Basel, Switzerland)
DO  - 10.3390/medsci14060631
UR  - https://europepmc.org/article/MED/42930550
AB  - Background/objectives  The thermal effects of therapeutic ultrasound (US) have been utilized to promote musculoskeletal healing. However, the optimal combination of US parameters, while studied in the past, has yet to be updated with the advent of newer US modalities, including low-intensity continuous ultrasound (LICUS). The purpose of this study was to evaluate the effects of US frequency, intensity, and duration on changes in tissue temperature and to compare the thermal response between traditional US and LICUS.Methods  Following PRISMA guidelines, PubMed, Embase, and Web of Science were searched for in vivo human studies that reported temperature changes and used standard ultrasound parameters (1 or 3 MHz, 0.1-2.0 W/cm², aqueous gel). US frequency, intensity, duration, effective radiating area (ERA), body region, and total energy delivered at three depths (1 cm, 3 cm, and 5 cm) were extracted. The outcome of interest was change in tissue temperature (i.e., ultrasonic diathermy). A mathematical model was used to interpolate missing data. Three-way ANOVA and t-tests were used to compare outcomes.Results  Nineteen studies (384 participants) were included. The weighted mean total energy delivered was 6698.5 ± 6767.4 J and was significantly correlated with tissue temperature change across all depths (r = 0.544, p < 0.001). At 1, 3, and 5 cm depths, significant interactions were observed between ultrasound intensity and frequency and between intensity and treatment duration (all p ≤ 0.05). Higher intensities generally produced greater temperature increases during shorter treatments (≤10 min), whereas longer treatment durations (≥60 min) at low intensity produced the greatest temperature increases overall. Frequency-dependent effects were also observed, with greater temperature increases at 3 MHz compared with 1 MHz at several intensity levels. LICUS delivered significantly more total energy than traditional 3 MHz US (13,854.4 ± 8129.6 vs. 3546.5 ± 2096.0 Joules, p < 0.001) and produced significantly greater tissue temperature increases at all depths (p < 0.001).Conclusions  Changes in tissue temperature are strongly correlated with the total US energy delivered. While frequency, intensity, and duration play a significant role in thermal energy, LICUS over sustained periods delivers significantly greater cumulative energy and, subsequently, greater tissue temperature change compared to traditional US.
SN  - 2076-3271
ER  -