Evaluation of Image Noise from Computed Tomography in an Organ-Specific Anthropomorphic Phantom

Abstract

Computed tomography (CT) is used ubiquitously for diagnostic imaging, with novel iterative reconstructions such as hybrid iterative reconstruction with partial model-based component (ASiR-V) and deep learning image reconstruction (DLIR) increasingly utilized. In conjunction, CT vendors have developed a noise index (NI) to reduce radiation dose during protocol development. However, it is unclear how these reconstruction algorithms reduce noise as NI changes, particularly across multiple organs. The goal of this study was to utilize an anthropomorphic phantom to evaluate image noise against the prescribed NI across different organs, determine if DLIR reduces image noise compared to ASiR-V, and use this relationship to determine the maximum volume CT dose index (CTDIvol) reduction at equivalent noise levels. Repeat images were acquired on a GE HealthCare Revolution Apex CT scanner across NI values in an anthropomorphic adult-sized phantom from Kyoto Kagaku with ASiR-V and DLIR. Organs-of-interest were contoured using TotalSegmentator in 3D Slicer. The correlation between the CTDIvol and NI was determined. The standard deviation of the difference in the repeat images was used as a noise metric (NM), correlated with NI, used to determine the NI at equivalent NM between ASiR-V and DLIR, then applied to determine the dose reduction and difference in NM. The relationship between NI and the resulting CTDIvol was found to be proportional to a power law of exponent -2.23. The maximum potential absolute dose reduction from using DLIR was found in the liver at 1.3 mGy with an NI of 7.9. Across all organs, the relative dose reduction increased, the NM-to-NI ratio decreased, and the noise reduction increased across NI. The relationship between image noise and the prescribed NI differed between ASiR-V and DLIR and varied by organ, with model-based dose reductions of up to 1.3 mGy in the liver.

Related

  1. Anthropomorphic phantom dosimetry and validation of 150–200 MeV very high-energy electron radiotherapy at CERN
    Fabio S. D’Andrea, Adam H. Aitkenhead, Robert Chuter +5
    Communications PhysicsPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
  2. Full-field fluorescence computed tomography (F3CT) using a calibrated virtual cone-beam pinhole geometry
    Thomas Zillhardt, Yunhui Chen, Alexander Rack +4
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationBiological & medical physicsarXiv
  3. Neural-network-based material identification in photon-counting computed tomography using region-of-interest spectral features
    A. Miadzvetski, V. Rozhkov, R. Sotenskii +2
    arXivPreprintCC BY-NC-ND 4.0Full textApplied physics & instrumentationarXiv
  4. Computed Tomography Reconstruction Algorithm Using Markov Random Field Model
    Taiga Shimomiya, Taichi Kusumi, Masayuki Uesugi +4
    arXivPreprintarXiv licenceFull textBiological & medical physicsComputational physicsarXiv
  5. Towards 3D fully randomized frequency-domain reconstruction of the speed of sound in breast ultrasound computed tomography
    Luca A. Forte
    arXivPreprintarXiv licenceFull textBiological & medical physicsComputational physicsarXiv
BibTeX
@misc{mccullum2026evaluation,
  title = {{Evaluation of Image Noise from Computed Tomography in an Organ-Specific Anthropomorphic Phantom}},
  author = {Lucas McCullum and Mojtaba Zarei and Andy Tsai and Michael J. Callahan and Peng Sun and Da Zhang},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.07357},
  eprint = {2611.07357},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.07357},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Evaluation of Image Noise from Computed Tomography in an Organ-Specific Anthropomorphic Phantom
AU  - Lucas McCullum
AU  - Mojtaba Zarei
AU  - Andy Tsai
AU  - Michael J. Callahan
AU  - Peng Sun
AU  - Da Zhang
PY  - 2026
DA  - 2026/11/05
PB  - arXiv
DO  - 10.48550/arxiv.2611.07357
UR  - https://arxiv.org/abs/2611.07357
AB  - Computed tomography (CT) is used ubiquitously for diagnostic imaging, with novel iterative reconstructions such as hybrid iterative reconstruction with partial model-based component (ASiR-V) and deep learning image reconstruction (DLIR) increasingly utilized. In conjunction, CT vendors have developed a noise index (NI) to reduce radiation dose during protocol development. However, it is unclear how these reconstruction algorithms reduce noise as NI changes, particularly across multiple organs. The goal of this study was to utilize an anthropomorphic phantom to evaluate image noise against the prescribed NI across different organs, determine if DLIR reduces image noise compared to ASiR-V, and use this relationship to determine the maximum volume CT dose index (CTDIvol) reduction at equivalent noise levels. Repeat images were acquired on a GE HealthCare Revolution Apex CT scanner across NI values in an anthropomorphic adult-sized phantom from Kyoto Kagaku with ASiR-V and DLIR. Organs-of-interest were contoured using TotalSegmentator in 3D Slicer. The correlation between the CTDIvol and NI was determined. The standard deviation of the difference in the repeat images was used as a noise metric (NM), correlated with NI, used to determine the NI at equivalent NM between ASiR-V and DLIR, then applied to determine the dose reduction and difference in NM. The relationship between NI and the resulting CTDIvol was found to be proportional to a power law of exponent -2.23. The maximum potential absolute dose reduction from using DLIR was found in the liver at 1.3 mGy with an NI of 7.9. Across all organs, the relative dose reduction increased, the NM-to-NI ratio decreased, and the noise reduction increased across NI. The relationship between image noise and the prescribed NI differed between ASiR-V and DLIR and varied by organ, with model-based dose reductions of up to 1.3 mGy in the liver.
ER  -