Retroperitoneal Robot‐Assisted Radical Nephroureterectomy Using the Hugo RAS System in a 135‐cm‐Tall Adult: Technical Strategies for Minimizing External Arm Interference
- 1Division of Urology, Department of Surgery, Faculty of Medicine Tottori University Yonago Japan
Abstract
Introduction: The Hugo RAS system uses four independent arm carts, making external arm interference a potential challenge in adults with very short stature. We report retroperitoneal robot‐assisted radical nephroureterectomy in a 135‐cm‐tall adult.
Case Presentation: A woman in her 80s with a bladder tumor and cT1N0M0 left renal pelvic cancer underwent transurethral resection of the bladder tumor and retroperitoneal Hugo RAS robot‐assisted radical nephroureterectomy during a single anesthetic session using a previously reported four‐robot‐port free‐access configuration. After renal mobilization, the ports were reassigned and all four carts repositioned caudally for distal ureteral dissection and bladder cuff excision. Total elapsed time was 338 min (287 min for nephroureterectomy); estimated blood loss was 50 mL, with no perioperative complications. The system log recorded one arm‐interference error without procedural interruption or clinical impact.
Conclusion: This configuration was feasible in this patient. Further experience is needed to define patient selection and broader applicability.
Related
- En bloc multivisceral resection for a giant retroperitoneal dedifferentiated liposarcoma: technical considerations.
- Advances in transcranial alternating current stimulation and temporal interference stimulation for neuropsychiatric disorders: mechanisms, technical developments, and preclinical evidence.
- Complication, Technical Pitfalls, and Strategies for Reducing Donor-Site Morbidity Following Connective Tissue Graft Harvesting: A Narrative Review
- Cystoscopic submucosal indocyanine green marking in robot-assisted radical nephroureterectomy: a multicenter cohort study
- Technical overview and clinical outcomes of transabdominal strategies to eliminate or neutralize staple-line intersection during low anterior resection: a systematic review.
BibTeX
@article{morizane2026retroperitoneal,
title = {{Retroperitoneal Robot‐Assisted Radical Nephroureterectomy Using the Hugo RAS System in a 135‐cm‐Tall Adult: Technical Strategies for Minimizing External Arm Interference}},
author = {Shuichi Morizane and Akira Hasegawa and Jo Tamura and Hiroshi Yamane and Ryutaro Shimizu and Shogo Teraoka and Ryoma Nishikawa and Yusuke Kimura and Katsuya Hikita and Atsushi Takenaka},
journal = {IJU Case Reports},
year = {2026},
month = nov,
doi = {10.1002/iju5.70294},
url = {https://doi.org/10.1002/iju5.70294},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Retroperitoneal Robot‐Assisted Radical Nephroureterectomy Using the Hugo RAS System in a 135‐cm‐Tall Adult: Technical Strategies for Minimizing External Arm Interference
AU - Shuichi Morizane
AU - Akira Hasegawa
AU - Jo Tamura
AU - Hiroshi Yamane
AU - Ryutaro Shimizu
AU - Shogo Teraoka
AU - Ryoma Nishikawa
AU - Yusuke Kimura
AU - Katsuya Hikita
AU - Atsushi Takenaka
PY - 2026
DA - 2026/11/15
JO - IJU Case Reports
DO - 10.1002/iju5.70294
UR - https://doi.org/10.1002/iju5.70294
AB - Introduction: The Hugo RAS system uses four independent arm carts, making external arm interference a potential challenge in adults with very short stature. We report retroperitoneal robot‐assisted radical nephroureterectomy in a 135‐cm‐tall adult. Case Presentation: A woman in her 80s with a bladder tumor and cT1N0M0 left renal pelvic cancer underwent transurethral resection of the bladder tumor and retroperitoneal Hugo RAS robot‐assisted radical nephroureterectomy during a single anesthetic session using a previously reported four‐robot‐port free‐access configuration. After renal mobilization, the ports were reassigned and all four carts repositioned caudally for distal ureteral dissection and bladder cuff excision. Total elapsed time was 338 min (287 min for nephroureterectomy); estimated blood loss was 50 mL, with no perioperative complications. The system log recorded one arm‐interference error without procedural interruption or clinical impact. Conclusion: This configuration was feasible in this patient. Further experience is needed to define patient selection and broader applicability.
SN - 2577-171X
ER -