Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 18 min ago
Peer-reviewedCC BYJournal of functional biomaterials

Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility.

  1. 1Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 112, Taiwan.
  2. 2Department of Orthopedics, Tri-Service General Hospital Songshan Branch, National Defense Medical University, Taipei 105, Taiwan.
  3. 3Medical Device Innovation & Translation Center, National Yang Ming Chiao Tung University, Taipei 112, Taiwan.

Abstract

Fixation of tibial eminence avulsion fractures (TEAFs) in skeletally immature patients requires adequate mechanical stability within a limited insertion depth to minimize the risk of physeal injury. Conventional transosseous cortical-button fixation (TCBF) requires the creation of tibial bone tunnels, whereas conventional suture anchors may have excessive insertion depths. In our previous study, a short expandable-wing (SEW) suture anchor (9.5 mm in length and 5.5 mm in diameter) with CNC-machined solid wings was developed to enhance fixation strength within a limited bone volume. In the present study, a second-generation SEW anchor was developed by replacing the solid wings with 3D-printed Ti6Al4V lattice wings to provide a potentially more favorable bone-implant interface. The mechanical performance of CNC-SEW and metal additively manufactured SEW (MAM-SEW) anchors was evaluated using polyurethane-block pull-out testing and a porcine TEAF model with single- and double-suture TCBF controls. Cytocompatibility was assessed using an MG-63 direct-contact MTT assay. Pull-out loads were 574.8 ± 10.6 N for CNC-SEW and 501.2 ± 39.2 N for MAM-SEW, compared with 429.0 ± 29.0 N for a historical TWINFIX comparator. After 200 loading cycles in the porcine model, cumulative displacements were 0.9 and 0.7 mm for CNC-SEW and MAM-SEW, respectively, compared with 2.2 and 1.3 mm for single- and double-suture TCBF. The corresponding ultimate failure loads were 278.88 and 292.56 N for the SEW groups, compared with 109.86 and 223.56 N for the TCBF groups. The MAM-SEW group also exhibited higher MG-63 metabolic activity than the CNC-SEW group. These findings demonstrate favorable initial fixation performance and preliminary cytocompatibility of the lattice-wing SEW anchor, supporting its potential application in TEAF fixation. Further studies are required to evaluate long-term osseointegration and physeal safety.

Related

  1. Effect of Surface Roughness and Polyelectrolyte Multilayer Coatings on the In Vitro Cytocompatibility of Additively Manufactured Titanium Implants
    CINDY REINHOLDT, TONYA D. ANDREEVA, ANNE JAHN +5
    In VivoPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  2. Additively manufactured stimulus-responsive shape memory polymers for multi-functional biomedical applications
    Quanjin Ma, Quanjin Ma, Quanjin Ma +5
    Frontiers in Soft MatterPeer-reviewedCC BYFull textGeneral chemistryGeneral medicineDOAJ
  3. Surface Roughness as a Determinant of the Immunological Tissue Response to Additively Manufactured Titanium Implants
    MIKE BARBECK, SVEN PANTERMEHL, JULIA STAMMKOETTER +9
    In VivoPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  4. Over-the-Counter Whitening Effects on Optical Properties of Additively-Manufactured Permanent Resins
    Kardelen Kiran, Ayse Tugba Erturk-Avunduk, Sevim Atilan Yavuz +1
    International Dental JournalPeer-reviewedCC BYFull textGeneral medicineDOAJ
  5. Effect of localized thermal history on martensitic microstructure and microhardness variation in wire-arc additively manufactured 17–4 PH stainless steel beads
    Annayath Maqbool, Abul Fazal M. Arif, Ahmed J. Qureshi +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossrefDOAJ
BibTeX
@article{tsai2026short,
  title = {{Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility.}},
  author = {Chia-Hung Tsai and Hsu-Wei Lin and Hsuan-Wen Wang and Yen Cheng and Chiao-Min Chang and Rong-Chen Lin and Chun-Li Lin},
  journal = {Journal of functional biomaterials},
  year = {2026},
  month = nov,
  doi = {10.3390/jfb17110584},
  url = {https://europepmc.org/article/MED/43083029},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Short Expandable-Wing Suture Anchors for Tibial Eminence Avulsion Fracture Fixation: Effects of Solid Versus Additively Manufactured Lattice Wings on Biomechanical Performance and Cytocompatibility.
AU  - Chia-Hung Tsai
AU  - Hsu-Wei Lin
AU  - Hsuan-Wen Wang
AU  - Yen Cheng
AU  - Chiao-Min Chang
AU  - Rong-Chen Lin
AU  - Chun-Li Lin
PY  - 2026
DA  - 2026/11/18
JO  - Journal of functional biomaterials
DO  - 10.3390/jfb17110584
UR  - https://europepmc.org/article/MED/43083029
AB  - Fixation of tibial eminence avulsion fractures (TEAFs) in skeletally immature patients requires adequate mechanical stability within a limited insertion depth to minimize the risk of physeal injury. Conventional transosseous cortical-button fixation (TCBF) requires the creation of tibial bone tunnels, whereas conventional suture anchors may have excessive insertion depths. In our previous study, a short expandable-wing (SEW) suture anchor (9.5 mm in length and 5.5 mm in diameter) with CNC-machined solid wings was developed to enhance fixation strength within a limited bone volume. In the present study, a second-generation SEW anchor was developed by replacing the solid wings with 3D-printed Ti6Al4V lattice wings to provide a potentially more favorable bone-implant interface. The mechanical performance of CNC-SEW and metal additively manufactured SEW (MAM-SEW) anchors was evaluated using polyurethane-block pull-out testing and a porcine TEAF model with single- and double-suture TCBF controls. Cytocompatibility was assessed using an MG-63 direct-contact MTT assay. Pull-out loads were 574.8 ± 10.6 N for CNC-SEW and 501.2 ± 39.2 N for MAM-SEW, compared with 429.0 ± 29.0 N for a historical TWINFIX comparator. After 200 loading cycles in the porcine model, cumulative displacements were 0.9 and 0.7 mm for CNC-SEW and MAM-SEW, respectively, compared with 2.2 and 1.3 mm for single- and double-suture TCBF. The corresponding ultimate failure loads were 278.88 and 292.56 N for the SEW groups, compared with 109.86 and 223.56 N for the TCBF groups. The MAM-SEW group also exhibited higher MG-63 metabolic activity than the CNC-SEW group. These findings demonstrate favorable initial fixation performance and preliminary cytocompatibility of the lattice-wing SEW anchor, supporting its potential application in TEAF fixation. Further studies are required to evaluate long-term osseointegration and physeal safety.
SN  - 2079-4983
ER  -