Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 54 min ago
Peer-reviewedCC BY-NC-ND 4.0In Vivo

Effect of Surface Roughness and Polyelectrolyte Multilayer Coatings on the In Vitro Cytocompatibility of Additively Manufactured Titanium Implants

  1. 1Clinic and Policlinic for Dermatology, Venereology and Allergology, University Medical Center Rostock, Rostock, Germany
  2. 2Faculty Life Sciences, Reutlingen University, Reutlingen, Germany
  3. 3Laser Zentrum Hannover e.V., Hannover, Germany

Abstract

Background/Aim: Titanium alloys are widely used in orthopedic and dental implants due to their favorable mechanical properties and biocompatibility. Additive manufacturing enables complex implant geometries but results in increased surface roughness, which may influence cellular behavior. Surface coatings are intended to improve cell adhesion and biocompatibility. This study investigates the cytocompatibility of additively manufactured titanium surfaces by assessing combined effects of micrometer-scale roughness and nanometer-thick polyelectrolyte multilayer coatings. Cytocompatibility was examined through fibroblast and osteoblast adhesion, viability, proliferation, and cytotoxicity to determine suitability for biomedical implant applications.

Materials and Methods: Cell adhesion of MC3T3 osteoblasts and L929 fibroblasts on the different substrates, both uncoated and surface-modified, was quantitatively assessed using live/dead staining. Substrate-induced cytotoxicity was evaluated by measuring lactate dehydrogenase (LDH) release. In addition, cellular viability was determined using the XTT assay, while cell proliferation was analyzed by incorporation of 5-bromo-2′-deoxyuridine (BrdU).

Results: The coatings composed of synthetic polyelectrolyte multilayers combined with the lowest roughness level enhanced preosteoblast viability. Fibroblast’s viability remained unaffected by surface topography or coating. Proliferation was more strongly influenced by surface structure and coating in fibroblasts than in preosteoblasts.

Conclusion: Cell adhesion and proliferation showed cell type-specific responses to surface roughness and polyelectrolyte multilayer coatings of titanium implants, with fibroblasts benefiting from synthetic coatings and preosteoblasts responding predominantly to surface topography. All coatings met the requirements for cytocompatibility according to DIN EN ISO 10993-5, with no adverse effects on cell viability, proliferation, or substrate-dependent toxicity. Therefore, polyelectrolyte multilayer coatings appear to be a feasible surface modification strategy for applications in biomedical implant.

Related

  1. Surface Roughness as a Determinant of the Immunological Tissue Response to Additively Manufactured Titanium Implants
    MIKE BARBECK, SVEN PANTERMEHL, JULIA STAMMKOETTER +9
    In VivoPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  2. Effect of localized thermal history on martensitic microstructure and microhardness variation in wire-arc additively manufactured 17–4 PH stainless steel beads
    Annayath Maqbool, Abul Fazal M. Arif, Ahmed J. Qureshi +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossrefDOAJ
  3. Experimental study of TPU and SEBS additively manufactured leaflets for novel aortic valve polymer TAVI prosthesis
    Alex G. Kuchumov, Denis Khoroshev, Aleksandra Kutuzova +7
    Frontiers in Bioengineering and BiotechnologyPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  4. Mesoporous Silica-Supported TiO₂ Composite Sunscreen: Combining Low Whitening, Reduced Photoactivity, and Favorable Cytocompatibility
    Haijun Zheng, Yanmiao Li, Kaixin Wu +5
    CosmeticsPeer-reviewedCC BYFull textGeneral chemistryGeneral medicineDOAJ
  5. Modified dual-portal robotic-assisted thoracic surgery using a Japanese-manufactured robotic platform
    JTCVS techniquesPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{reinholdt2026effect,
  title = {{Effect of Surface Roughness and Polyelectrolyte Multilayer Coatings on the In Vitro Cytocompatibility of Additively Manufactured Titanium Implants}},
  author = {CINDY REINHOLDT and TONYA D. ANDREEVA and ANNE JAHN and SVEN PANTERMEHL and RUMEN KRASTEV and JÖRG HERMSDORF and MIKE BARBECK and OLE JUNG},
  journal = {In Vivo},
  year = {2026},
  month = oct,
  doi = {10.21873/invivo.14484},
  url = {https://doi.org/10.21873/invivo.14484},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Effect of Surface Roughness and Polyelectrolyte Multilayer Coatings on the In Vitro Cytocompatibility of Additively Manufactured Titanium Implants
AU  - CINDY REINHOLDT
AU  - TONYA D. ANDREEVA
AU  - ANNE JAHN
AU  - SVEN PANTERMEHL
AU  - RUMEN KRASTEV
AU  - JÖRG HERMSDORF
AU  - MIKE BARBECK
AU  - OLE JUNG
PY  - 2026
DA  - 2026/10/29
JO  - In Vivo
DO  - 10.21873/invivo.14484
UR  - https://doi.org/10.21873/invivo.14484
AB  - Background/Aim: Titanium alloys are widely used in orthopedic and dental implants due to their favorable mechanical properties and biocompatibility. Additive manufacturing enables complex implant geometries but results in increased surface roughness, which may influence cellular behavior. Surface coatings are intended to improve cell adhesion and biocompatibility. This study investigates the cytocompatibility of additively manufactured titanium surfaces by assessing combined effects of micrometer-scale roughness and nanometer-thick polyelectrolyte multilayer coatings. Cytocompatibility was examined through fibroblast and osteoblast adhesion, viability, proliferation, and cytotoxicity to determine suitability for biomedical implant applications.  Materials and Methods: Cell adhesion of MC3T3 osteoblasts and L929 fibroblasts on the different substrates, both uncoated and surface-modified, was quantitatively assessed using live/dead staining. Substrate-induced cytotoxicity was evaluated by measuring lactate dehydrogenase (LDH) release. In addition, cellular viability was determined using the XTT assay, while cell proliferation was analyzed by incorporation of 5-bromo-2′-deoxyuridine (BrdU).  Results: The coatings composed of synthetic polyelectrolyte multilayers combined with the lowest roughness level enhanced preosteoblast viability. Fibroblast’s viability remained unaffected by surface topography or coating. Proliferation was more strongly influenced by surface structure and coating in fibroblasts than in preosteoblasts.  Conclusion: Cell adhesion and proliferation showed cell type-specific responses to surface roughness and polyelectrolyte multilayer coatings of titanium implants, with fibroblasts benefiting from synthetic coatings and preosteoblasts responding predominantly to surface topography. All coatings met the requirements for cytocompatibility according to DIN EN ISO 10993-5, with no adverse effects on cell viability, proliferation, or substrate-dependent toxicity. Therefore, polyelectrolyte multilayer coatings appear to be a feasible surface modification strategy for applications in biomedical implant.
SN  - 0258-851X
SN  - 1791-7549
ER  -