Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BYCardiology research

Outcomes After Transcatheter Aortic Valve Implantation Using the Self-Expanding Allegra Valve in Daily Practice

  1. 1Department of Cardiology, Heart and Vascular Center Bad Bevensen, Bad Bevensen, Germany
  2. 2Department of Cardiothoracic Surgery, Heart and Vascular Center Bad Bevensen, Bad Bevensen, Germany
  3. 3Department of Cardiac Surgery, Helios Clinic Siegburg, Siegburg, Germany

Abstract

Background: Limited data are available of the self-expanding Allegra transcatheter heart valve (THV). The aim of this study was to investigate the safety and outcome of transcatheter aortic valve implantation (TAVI) using the Allegra THV in daily practice.

Methods: Between February 2018 and September 2024, 142 consecutive patients underwent Allegra TAVI at the Heart and Vascular Center, Bad Bevensen, Germany, either for native aortic stenosis (AS) (n = 117, median 82 (interquartile range 80–86) years) or degenerated aortic bioprostheses (n = 25, 80 (73–84) years) as valve-in-valve (ViV) procedures. Endpoints were defined according to Valve Academic Research Consortium-3 criteria.

Results: The logistic EuroSCORE II was significantly higher in the cohort of patients with degenerated aortic bioprostheses than in those with native AS (14.4% (6.6–25.3%) versus 3.3% (2.5–5.7%), P < 0.01). Technical success was nearly identical in both cohorts (91.5% of patients with native AS and 92.0% of patients with ViV TAVI). Postinterventional aortic regurgitation ≥ moderate was found in 4.5% of patients with native AS and was not present in any patient with ViV TAVI. In the native AS cohort, mean and maximal aortic pressure gradients decreased from 44 (36–54) mm Hg and 72 (60–87) mm Hg before the intervention to 6 (5–9) mm Hg and 12 (9–15) mm Hg after Allegra TAVI. In the ViV cohort, mean and maximal transvalvular pressure gradients decreased from 34 (27–43) mm Hg and 59 (44–70) mm Hg to 9 (7–11) mm Hg and 16 (14–23) mm Hg, respectively. Periprocedural mortality rates (≤ 30 days) were 6.8% and 12.0% in the native AS and ViV cohorts, respectively. One-year and 3-year survival rates were 87.2% and 73.2% in the native AS cohort and 89.8% and 75.1% in the ViV cohort, respectively.

Conclusions: TAVI using the self-expanding Allegra THV system is safe and leads to acute hemodynamic improvements in patients with native AS or degenerated aortic bioprostheses.

Related

  1. Balloon-Expandable Vs Self-Expanding Valves for Transcatheter Aortic Valve Implantation in Internally Stented Surgical Valves
    Daisuke Sato, Noriaki Moriyama, Yoichi Sugiyama +12
    CJC openPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Impact of prolonged balloon inflation on valve expansion and early clinical outcomes following contemporary balloon-expandable transcatheter aortic valve implantation
    Francesco Cardaioli, Luca Nai Fovino, Tommaso Fabris +6
    EuroInterventionPeer-reviewedLicence not statedFull text1 citedCardiovascular medicinePMC
  3. Early Post-transcatheter Aortic Valve Implantation (TAVI) Haemodynamics With SAPIEN Balloon-Expandable and Evolut Self-Expanding Valve Platforms: A Retrospective Single-Centre Cohort Study.
    Behzad Masood, Mamoon Ahmed, Syed M Usman +2
    CureusPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Sex Differences in Clinical Outcomes After Transcatheter Aortic Valve Implantation ― Insights From a Nationwide Japanese Registry ―
    Kentaro Mitsui, Kensuke Takagi, Yu Kataoka +19
    Circulation JournalPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineJ-STAGE
  5. Impact of Continuous Baseline and Discharge Blood Pressure on Outcomes After Transcatheter Aortic Valve Implantation
    Thorald Stolte, Jakob Johannes Reichl, Felix Goetzinger +9
    Journal of the American Heart AssociationPeer-reviewedCC BY-NC-NDCardiovascular medicineCrossref
BibTeX
@article{zemaite2026outcomes,
  title = {{Outcomes After Transcatheter Aortic Valve Implantation Using the Self-Expanding Allegra Valve in Daily Practice}},
  author = {Justina Zemaite and Stefan Erler and Ulrich Schafer and Steffen Vormfelde and Bjoern Andrew Remppis and Katja Bohmann and Barbara Maria Januszewski and Christof Burgdorf},
  journal = {Cardiology research},
  year = {2026},
  month = oct,
  doi = {10.14740/cr2291},
  url = {https://europepmc.org/article/PMC/PMC13719659},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Outcomes After Transcatheter Aortic Valve Implantation Using the Self-Expanding Allegra Valve in Daily Practice
AU  - Justina Zemaite
AU  - Stefan Erler
AU  - Ulrich Schafer
AU  - Steffen Vormfelde
AU  - Bjoern Andrew Remppis
AU  - Katja Bohmann
AU  - Barbara Maria Januszewski
AU  - Christof Burgdorf
PY  - 2026
DA  - 2026/10/24
JO  - Cardiology research
DO  - 10.14740/cr2291
UR  - https://europepmc.org/article/PMC/PMC13719659
AB  - Background: Limited data are available of the self-expanding Allegra transcatheter heart valve (THV). The aim of this study was to investigate the safety and outcome of transcatheter aortic valve implantation (TAVI) using the Allegra THV in daily practice.  Methods: Between February 2018 and September 2024, 142 consecutive patients underwent Allegra TAVI at the Heart and Vascular Center, Bad Bevensen, Germany, either for native aortic stenosis (AS) (n = 117, median 82 (interquartile range 80–86) years) or degenerated aortic bioprostheses (n = 25, 80 (73–84) years) as valve-in-valve (ViV) procedures. Endpoints were defined according to Valve Academic Research Consortium-3 criteria.  Results: The logistic EuroSCORE II was significantly higher in the cohort of patients with degenerated aortic bioprostheses than in those with native AS (14.4% (6.6–25.3%) versus 3.3% (2.5–5.7%), P < 0.01). Technical success was nearly identical in both cohorts (91.5% of patients with native AS and 92.0% of patients with ViV TAVI). Postinterventional aortic regurgitation ≥ moderate was found in 4.5% of patients with native AS and was not present in any patient with ViV TAVI. In the native AS cohort, mean and maximal aortic pressure gradients decreased from 44 (36–54) mm Hg and 72 (60–87) mm Hg before the intervention to 6 (5–9) mm Hg and 12 (9–15) mm Hg after Allegra TAVI. In the ViV cohort, mean and maximal transvalvular pressure gradients decreased from 34 (27–43) mm Hg and 59 (44–70) mm Hg to 9 (7–11) mm Hg and 16 (14–23) mm Hg, respectively. Periprocedural mortality rates (≤ 30 days) were 6.8% and 12.0% in the native AS and ViV cohorts, respectively. One-year and 3-year survival rates were 87.2% and 73.2% in the native AS cohort and 89.8% and 75.1% in the ViV cohort, respectively.  Conclusions: TAVI using the self-expanding Allegra THV system is safe and leads to acute hemodynamic improvements in patients with native AS or degenerated aortic bioprostheses.
SN  - 1923-2829
SN  - 1923-2837
ER  -