Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 48 min ago
Peer-reviewedCC BY 4.0Cureus

Dynamic Mechanical Alignment in Total Knee Arthroplasty for Varus Morphotypes: A Retrospective Study of a Manual Technique and Midterm Outcomes

  1. 1Orthopedics and Traumatology, RHL Rajasthan Hospital, Jaipur, IND
  2. 2Orthopedics and Robotic Joint Replacement, RHL Rajasthan Hospital, Jaipur, IND

Abstract

Background: This study evaluated the midterm clinical and radiological outcomes of a manual dynamic mechanical alignment (DMA) technique for primary total knee arthroplasty (TKA) in knees with varus osteoarthritis. Materials and methods: This single-center retrospective observational study included 300 patients (542 knees) who underwent primary TKA using a manual DMA algorithm between July 2022 and July 2023. Clinical and radiological records were reviewed through July 2025, providing 24-36 months of overall follow-up. The primary analysis reported range of motion (ROM), Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and radiological parameters, which correspond to the standardized 12-month postoperative assessment, whereas pain was assessed using the VAS at one month. Outcomes also included coronal plane alignment of the knee (CPAK) classification, arithmetic hip-knee-ankle angle, joint-line obliquity, and postoperative complications. Results: Mean ROM increased from 95.66 ± 11.56° preoperatively to 133.82 ± 7.69° at 12 months. Mean KSS increased from 24.7 ± 14.63 to 85.58 ± 8.35, while mean WOMAC decreased from 62.62 ± 7.01 to 10.82 ± 13. All 542 knees achieved the intended physiologic mediolateral balance pattern without superficial medial collateral ligament (sMCL) release, and 418 knees (77.12%) retained their preoperative CPAK class. Conclusions: In this retrospective cohort, manual DMA improved clinical outcome measures at the standardized 12-month assessment, and it achieved the intended physiologic mediolateral balance pattern without sMCL release. These findings demonstrate technical feasibility but do not establish superiority over other alignment strategies.

Related

  1. Imageless Robotic-Assisted Kinematic Alignment Total Knee Arthroplasty: Surgical Technique and Preliminary Outcomes of an Initial Single-Surgeon Case Series
    Ren Yi Kow, Yong Ng, Jeremy Tze En Lim +4
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
  2. Functional alignment versus mechanical alignment in total knee arthroplasty: a meta-analysis of randomized controlled trials
    Xiao-peng Gao, Xue-dong Sun, Qing-shuai Wang +2
    BMC Musculoskeletal DisordersPeer-reviewedCC BY-NC-ND 4.0Full text1 citedSurgery & anaesthesiaPMC
  3. Kinematic Alignment Using Conventional Mechanical-Alignment Instruments with 3D-Printed Tibial Recut Guide Versus Manual Mechanical Alignment in Total Knee Arthroplasty: An IPTW-Adjusted Comparative Cohort Study
    Bui Hong Thien Khanh, Pham Thi Cam Van, Nguyen Phuc Thinh
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  4. Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study
    Wei-Cheng Tseng, Ching-Heng Lin, Yu-Tsung Lin +6
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Functional Versus Mechanical Alignment in Robotic-Assisted Primary Total Knee Arthroplasty: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials
    Nay Aung Zin, Sai Tun, Min Maung Maung +9
    CureusPeer-reviewedCC BYFull textPhysiologyEurope PMCPMC
BibTeX
@article{jain2026dynamic,
  title = {{Dynamic Mechanical Alignment in Total Knee Arthroplasty for Varus Morphotypes: A Retrospective Study of a Manual Technique and Midterm Outcomes}},
  author = {Jitesh K Jain and Ruchi Goyal and Harish Bansal},
  journal = {Cureus},
  year = {2026},
  month = oct,
  doi = {10.7759/cureus.117845},
  url = {https://doi.org/10.7759/cureus.117845},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Dynamic Mechanical Alignment in Total Knee Arthroplasty for Varus Morphotypes: A Retrospective Study of a Manual Technique and Midterm Outcomes
AU  - Jitesh K Jain
AU  - Ruchi Goyal
AU  - Harish Bansal
PY  - 2026
DA  - 2026/10/13
JO  - Cureus
DO  - 10.7759/cureus.117845
UR  - https://doi.org/10.7759/cureus.117845
AB  - Background: This study evaluated the midterm clinical and radiological outcomes of a manual dynamic mechanical alignment (DMA) technique for primary total knee arthroplasty (TKA) in knees with varus osteoarthritis. Materials and methods: This single-center retrospective observational study included 300 patients (542 knees) who underwent primary TKA using a manual DMA algorithm between July 2022 and July 2023. Clinical and radiological records were reviewed through July 2025, providing 24-36 months of overall follow-up. The primary analysis reported range of motion (ROM), Knee Society Score (KSS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and radiological parameters, which correspond to the standardized 12-month postoperative assessment, whereas pain was assessed using the VAS at one month. Outcomes also included coronal plane alignment of the knee (CPAK) classification, arithmetic hip-knee-ankle angle, joint-line obliquity, and postoperative complications. Results: Mean ROM increased from 95.66 ± 11.56° preoperatively to 133.82 ± 7.69° at 12 months. Mean KSS increased from 24.7 ± 14.63 to 85.58 ± 8.35, while mean WOMAC decreased from 62.62 ± 7.01 to 10.82 ± 13. All 542 knees achieved the intended physiologic mediolateral balance pattern without superficial medial collateral ligament (sMCL) release, and 418 knees (77.12%) retained their preoperative CPAK class. Conclusions: In this retrospective cohort, manual DMA improved clinical outcome measures at the standardized 12-month assessment, and it achieved the intended physiologic mediolateral balance pattern without sMCL release. These findings demonstrate technical feasibility but do not establish superiority over other alignment strategies.
SN  - 2168-8184
ER  -