Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 33 min ago
Peer-reviewedCC BYACS measurement science au

Leaching-Resistant Self-Plasticized Poly(Vinyl Chloride) (PVC) as a Matrix for Ion-Selective Electrodes.

  1. 1Department of Inorganic and Analytical Chemistry, University of Geneva, Quai Ernest-Ansermet 30, Geneva CH-1211, Switzerland.

Abstract

Polymer-based ion-selective electrodes typically rely on plasticized polymeric membranes to incorporate functional sensing components, but leaching of plasticizer into solution can negatively affect the response stability, operability, and overall lifetime of these sensors. Moreover, plasticizer loss can result in cytotoxicity, which is especially undesirable in wearable sensors and bioanalytical probes, requiring strict regulation and monitoring of the plasticizers used. To help overcome this challenge, a new class of self-plasticized poly-(vinyl chloride) (PVC) derivatives was synthesized here by grafting a plasticizer-like group onto azide-modified PVC using a highly efficient azide-alkyne Huisgen cycloaddition "click" reaction. The resulting polymer is naturally elastic and malleable that allows for the dissolution of sensing components and ion diffusion through the selective membrane, overcoming the need for an additional plasticizer. When applied to a library of ions (Ca²⁺, H⁺, K⁺, NO₃ ⁻), the resulting membrane electrodes demonstrated promising stability and lifetime with an overall drift of 0.3 mV for the calcium-selective electrode over a testing period of 5 days. This synthetic approach provides a promising pathway for developing plasticizer leak-free, high-performance, and operationally stable sensors.

Related

  1. Ti₃C₂T x MXene-Enhanced Paper-Based Ion-Selective Electrodes for Sweat Sodium Monitoring.
    Wanda Cimmino, Md Abu Zahed, Michele Spinelli +4
    ACS measurement science auPeer-reviewedCC BY-NC-NDFull textSystems & synthetic biologyEurope PMC
  2. Bedside screening of carbapenem-resistant Enterobacteriaceae using selective agar plates: A low-cost, laboratory-independent approach for rural healthcare facilities
    The Anh Ngo, Hieu Thi Nguyen, Nhung Ngoc Hoang +2
    PLOS Global Public HealthPeer-reviewedCC BY 4.0Full textMicrobiologyPharmacology & toxicologyPLOS
  3. Truncating leguminous fixation and post‐harvest scavenging: Two pathways for reducing nitrate leaching in potato rotations
    Yefang Jiang, Judith Nyiraneza, Tandra Fraser +4
    Journal of Environmental QualityPeer-reviewedCC BY 4.0Full textPlant biologyPMC
  4. Evaluating urea-based nitrogen fertilization practices on greenhouse tomato growth and nitrate leaching in cold regions
    Changqing Li, Ziyi Wu, Haixu Wang +4
    Frontiers in plant sciencePeer-reviewedCC BYFull textPlant biologyEurope PMCCrossref
  5. Effects of Mepiquat Chloride Application Timing and Concentration on Soybean Plant Architecture and Stem Mechanical Properties
    Jiaqi Li, Zhipeng Qu, Xiaomei Li +4
    Plants (Basel, Switzerland)Peer-reviewedCC BYFull textPlant biologyEurope PMC
BibTeX
@article{gupta2026leachingresistant,
  title = {{Leaching-Resistant Self-Plasticized Poly(Vinyl Chloride) (PVC) as a Matrix for Ion-Selective Electrodes.}},
  author = {Geetansh Gupta and Tara Forrest and Eric Bakker},
  journal = {ACS measurement science au},
  year = {2026},
  month = jul,
  doi = {10.1021/acsmeasuresciau.6c00163},
  url = {https://europepmc.org/article/MED/42921418},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Leaching-Resistant Self-Plasticized Poly(Vinyl Chloride) (PVC) as a Matrix for Ion-Selective Electrodes.
AU  - Geetansh Gupta
AU  - Tara Forrest
AU  - Eric Bakker
PY  - 2026
DA  - 2026/07/26
JO  - ACS measurement science au
DO  - 10.1021/acsmeasuresciau.6c00163
UR  - https://europepmc.org/article/MED/42921418
AB  - Polymer-based ion-selective electrodes typically rely on plasticized polymeric membranes to incorporate functional sensing components, but leaching of plasticizer into solution can negatively affect the response stability, operability, and overall lifetime of these sensors. Moreover, plasticizer loss can result in cytotoxicity, which is especially undesirable in wearable sensors and bioanalytical probes, requiring strict regulation and monitoring of the plasticizers used. To help overcome this challenge, a new class of self-plasticized poly-(vinyl chloride) (PVC) derivatives was synthesized here by grafting a plasticizer-like group onto azide-modified PVC using a highly efficient azide-alkyne Huisgen cycloaddition "click" reaction. The resulting polymer is naturally elastic and malleable that allows for the dissolution of sensing components and ion diffusion through the selective membrane, overcoming the need for an additional plasticizer. When applied to a library of ions (Ca²⁺, H⁺, K⁺, NO₃ ⁻), the resulting membrane electrodes demonstrated promising stability and lifetime with an overall drift of 0.3 mV for the calcium-selective electrode over a testing period of 5 days. This synthetic approach provides a promising pathway for developing plasticizer leak-free, high-performance, and operationally stable sensors.
SN  - 2694-250X
ER  -