Skip to content
DraconiticResearch
Search Sources API
186,541 studies31 sourcesUpdated 35 min ago
Peer-reviewedCC BY-NC-NDACS measurement science au

Ti₃C₂T x MXene-Enhanced Paper-Based Ion-Selective Electrodes for Sweat Sodium Monitoring.

9 affiliations
  1. 1Department of Pharmacy, University of Naples Federico II, Naples 80131, Italy.
  2. 2Department of Neurology, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
  3. 3Center for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
  4. 4Department of Chemical Sciences, University of Naples "Federico II", Naples 80126, Italy.
  5. 5Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
  6. 6Center for Neurotrauma, Neurodegeneration, and Restoration, Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, Pennsylvania 1910, United States.
  7. 7Department of Physical Medicine and Rehabilitation, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.
  8. 8Bioelectronics Task Force at University of Naples Federico II, Via Cinthia 21, Naples 80126, Italy.
  9. 9Sbarro Institute for Cancer Research and Molecular Medicine, Center for Biotechnology, College of Science and Technology, Temple University, Philadelphia, Pennsylvania 19122, United States.

Abstract

Electrolyte balance plays a fundamental role in maintaining physiological homeostasis, as ionic fluctuations regulate cellular excitability, osmotic gradients, and neuromuscular signaling. Among electrolytes, sodium (Na⁺) is a critical biomarker for hydration status and several pathological conditions, including dehydration and cystic fibrosis. Here, this is the first report of Ti₃C₂T x MXene integrated as a solid-contact transducer on a paper-based screen-printed electrode (MPSPE) for ion-selective sensing of Na⁺ in sweat. The platform combines the sustainability and intrinsic capillarity of paper substrates with the exceptional electrical conductivity and surface reactivity of Ti₃C₂T x MXene. Prior to MXene deposition, oxygen plasma treatment was applied to improve surface hydrophilicity and promote homogeneous film formation. The optimized configuration, based on office paper modified with 3 mg mL⁻¹ MXene, exhibited a near-Nernstian slope of 0.0637 V/decade and an excellent linear correlation (R ² = 0.98) over the tested Na⁺ range (1-150 mM). The calculated limit of detection (LOD) and limit of quantification (LOQ) were 0.35 mM and 1.16 mM, respectively, while the coefficient of variation (%CV) was found to be 7.2%, confirming outstanding repeatability. The electrode demonstrated high selectivity toward Na⁺ over K⁺, Mg²⁺, and Ca²⁺ (log Kpot Na,j < -0.5). Validation with real sweat samples revealed an excellent correlation with the liquid chromatography-tandem mass spectrometry (LC-MS/MS) reference method (R ² = 0.96, mean correlation ≈ 99%). These results highlight the potential of MXene-modified paper electrodes as a low-cost, disposable, and environmentally friendly analytical platform for point-of-care electrolyte monitoring.

Related

  1. Leaching-Resistant Self-Plasticized Poly(Vinyl Chloride) (PVC) as a Matrix for Ion-Selective Electrodes.
    Geetansh Gupta, Tara Forrest, Eric Bakker
    ACS measurement science auPeer-reviewedCC BYFull textSystems & synthetic biologyEurope PMC
  2. Design and validation of a modular smart headband with embroidered electrodes for comfortable EEG monitoring
    Komal Komal, Frances Cleary, Ram Prasadh Narayanan +3
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
  3. Selective activation of tetrodotoxin-sensitive sodium channels by AaH-II drives arrhythmogenic late Na+ current in the heart
    Hugo Millet, Maureen Choteau-Bodor, Thomas Stervinou +14
    EP-EuropacePeer-reviewedCC BY 4.0Full textGeneral biologyCardiovascular medicineHAL
  4. Surimi Gel Quality Enhanced by κ-Carrageenan/Konjac Glucomannan and Sodium Caseinate-Stabilized Emulsion.
    Tianzhen Xiong, Lala Li, Guanchen Wu +2
    Gels (Basel, Switzerland)Peer-reviewedCC BYFull textZoology & animal behaviourEurope PMC
  5. Live 4D monitoring of fungal infection in an ex vivo model of fungal keratitis reveals enhanced efficacy of combined PACK-CXL and natamycin treatment
    O. Sivanesan, N. Van Rhijin, S. Y. Tang +2
    bioRxivPreprintCC BYFull textMicrobiologybioRxiv
BibTeX
@article{cimmino2026ti₃c₂t,
  title = {{Ti₃C₂T x MXene-Enhanced Paper-Based Ion-Selective Electrodes for Sweat Sodium Monitoring.}},
  author = {Wanda Cimmino and Md Abu Zahed and Michele Spinelli and Angela Amoresano and Jimin Jung and Flavia Vitale and Stefano Cinti},
  journal = {ACS measurement science au},
  year = {2026},
  month = sep,
  doi = {10.1021/acsmeasuresciau.6c00137},
  url = {https://europepmc.org/article/MED/42921092},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Ti₃C₂T x MXene-Enhanced Paper-Based Ion-Selective Electrodes for Sweat Sodium Monitoring.
AU  - Wanda Cimmino
AU  - Md Abu Zahed
AU  - Michele Spinelli
AU  - Angela Amoresano
AU  - Jimin Jung
AU  - Flavia Vitale
AU  - Stefano Cinti
PY  - 2026
DA  - 2026/09/21
JO  - ACS measurement science au
DO  - 10.1021/acsmeasuresciau.6c00137
UR  - https://europepmc.org/article/MED/42921092
AB  - Electrolyte balance plays a fundamental role in maintaining physiological homeostasis, as ionic fluctuations regulate cellular excitability, osmotic gradients, and neuromuscular signaling. Among electrolytes, sodium (Na⁺) is a critical biomarker for hydration status and several pathological conditions, including dehydration and cystic fibrosis. Here, this is the first report of Ti₃C₂T x MXene integrated as a solid-contact transducer on a paper-based screen-printed electrode (MPSPE) for ion-selective sensing of Na⁺ in sweat. The platform combines the sustainability and intrinsic capillarity of paper substrates with the exceptional electrical conductivity and surface reactivity of Ti₃C₂T x MXene. Prior to MXene deposition, oxygen plasma treatment was applied to improve surface hydrophilicity and promote homogeneous film formation. The optimized configuration, based on office paper modified with 3 mg mL⁻¹ MXene, exhibited a near-Nernstian slope of 0.0637 V/decade and an excellent linear correlation (R ² = 0.98) over the tested Na⁺ range (1-150 mM). The calculated limit of detection (LOD) and limit of quantification (LOQ) were 0.35 mM and 1.16 mM, respectively, while the coefficient of variation (%CV) was found to be 7.2%, confirming outstanding repeatability. The electrode demonstrated high selectivity toward Na⁺ over K⁺, Mg²⁺, and Ca²⁺ (log Kpot Na,j < -0.5). Validation with real sweat samples revealed an excellent correlation with the liquid chromatography-tandem mass spectrometry (LC-MS/MS) reference method (R ² = 0.96, mean correlation ≈ 99%). These results highlight the potential of MXene-modified paper electrodes as a low-cost, disposable, and environmentally friendly analytical platform for point-of-care electrolyte monitoring.
SN  - 2694-250X
ER  -