Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYJournal of functional biomaterials

Ti-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity.

  1. 1Nikolaev Institute of Inorganic Chemistry, Siberian Branch, Russian Academy of Sciences, Ac. Lavrentiev Ave. 3, 630090 Novosibirsk, Russia.
  2. 2Meshalkin National Medical Research Center, Ministry of Public Health of the Russian Federation, Rechkunovskaya Str. 15, 630055 Novosibirsk, Russia.

Abstract

Ti-based mesh implants ("titanium silk" TiS and NiTi alloy) offer excellent tissue integration for oncologic surgery but lack intrinsic antibacterial activity. To address this, we fabricated Ag nanoparticles and Ag/M (M = Pt, Au) heterostructures on mesh surfaces via vapor-phase deposition, with noble metal sublayers functionalized by Ag nanofilms and nanoclusters. The modified implants were comprehensively characterized using SEM, AFM, XPS, and ICP-AES and evaluated through in vitro biocompatibility and antibacterial assays. The functional performance of the heterostructures is governed by two key phenomena: a chemical sublayer effect and a geometry-dependent substrate effect, which together dictate ion release kinetics. The Ag/Au interface sustains Ag⁺ release, whereas Ag/Pt drives rapid Ag⁺ dissolution. All heterostructures demonstrated effective antibacterial activity against planktonic S. aureus within 24 h. Key factors responsible for reduction in the more resilient P. aeruginosa on the Ag/M heterostructures were hypothesized. Cytotoxicity was dictated by the released ion cocktail: Ag/Pt/NiTi exhibited elevated toxicity which may be associated with the combined release of Ag⁺, Ni²⁺ and Pt²⁺, whereas all Ag/Au-based heterostructures showed excellent biocompatibility (viability 75-108%). Notably, gold sublayers were associated with elevated IL-10 secretion by 72 h. Based on overall biological performance, Ag/Au heterostructures offering sustained antibacterial activity against planktonic bacteria, low cytotoxicity, and a cytokine profile that may be favorable for long-term integration are promising candidates for mesh implants. Also, h-Ag/Pt/TiS showed an optimal balance between rapid antibacterial action and biocompatibility and therefore appears to be a suitable candidate for further in vivo investigation.

Related

  1. Facile Fabrication of Multilayer Chemical Filters Based on Modified Activated Carbon and Activated Carbon Fiber Nonwovens for Airborne Molecular Contaminant Removal in Semiconductor Manufacturing
    Jia-Wun Li, Chia-Lin Li, Jen-Kai Yang +3
    PolymersPeer-reviewedCC BY 4.0Materials & polymersCrossref
  2. Fabrication and Performance of Thermally Triggered Active Fire-Extinguishing Patches Based on Perfluorohexanone Microcapsule-Modified Epoxy Resin
    Zihou Tian, Le Yang, Songdi Zhang +3
    PolymersPeer-reviewedCC BY 4.0Materials & polymersCrossref
  3. Fabrication and Characterization of 3D-Printed Polylactide Composite Scaffolds with Modified Graphene
    Worathep Khimlek, Jirawan Jindakeaw, Vitsarut Primpray +6
    ACS OmegaPeer-reviewedCC BY-NC-ND 4.0Full textGeneral chemistryCrossrefPMC
  4. Structural Characterization and Visible-Light Photocatalytic Performance of AgBr-Modified Zr-Containing Titanium Silicalite-1 (TS-1) Composites
    Hristina Lazarova, Elena Tacheva, Borislav Barbov +3
    MoleculesPeer-reviewedCC BY 4.0General chemistryCrossref
  5. Eco-Friendly Modified Fabrication of poly (lactic- co-glycolic acid) (PLGA) Nanoparticles from a Novel Utilized date seed Extract with Potent Antibacterial Properties isolated from Osteomyelitis Patients.
    Elaf Sameer, Suzan Saadi Hussain, Raad S. Sabry +1
    F1000ResearchPeer-reviewedCC BY 4.0Full textMaterials & polymersPMC
BibTeX
@article{dorovskikh2026ticontaining,
  title = {{Ti-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity.}},
  author = {Svetlana Dorovskikh and Evgeniia Vikulova and David Sergeevichev and Tatiana Guselnikova and Aleksey Kolodin and Anastasiya Fedorenko and Alexander Zheravin and Natalya Morozova},
  journal = {Journal of functional biomaterials},
  year = {2026},
  month = oct,
  doi = {10.3390/jfb17110547},
  url = {https://europepmc.org/article/MED/43082994},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Ti-Containing Mesh Implants Modified by Heterostructures Based on Noble Metal: Fabrication and Study of Biological Activity.
AU  - Svetlana Dorovskikh
AU  - Evgeniia Vikulova
AU  - David Sergeevichev
AU  - Tatiana Guselnikova
AU  - Aleksey Kolodin
AU  - Anastasiya Fedorenko
AU  - Alexander Zheravin
AU  - Natalya Morozova
PY  - 2026
DA  - 2026/10/27
JO  - Journal of functional biomaterials
DO  - 10.3390/jfb17110547
UR  - https://europepmc.org/article/MED/43082994
AB  - Ti-based mesh implants ("titanium silk" TiS and NiTi alloy) offer excellent tissue integration for oncologic surgery but lack intrinsic antibacterial activity. To address this, we fabricated Ag nanoparticles and Ag/M (M = Pt, Au) heterostructures on mesh surfaces via vapor-phase deposition, with noble metal sublayers functionalized by Ag nanofilms and nanoclusters. The modified implants were comprehensively characterized using SEM, AFM, XPS, and ICP-AES and evaluated through in vitro biocompatibility and antibacterial assays. The functional performance of the heterostructures is governed by two key phenomena: a chemical sublayer effect and a geometry-dependent substrate effect, which together dictate ion release kinetics. The Ag/Au interface sustains Ag⁺ release, whereas Ag/Pt drives rapid Ag⁺ dissolution. All heterostructures demonstrated effective antibacterial activity against planktonic S. aureus within 24 h. Key factors responsible for reduction in the more resilient P. aeruginosa on the Ag/M heterostructures were hypothesized. Cytotoxicity was dictated by the released ion cocktail: Ag/Pt/NiTi exhibited elevated toxicity which may be associated with the combined release of Ag⁺, Ni²⁺ and Pt²⁺, whereas all Ag/Au-based heterostructures showed excellent biocompatibility (viability 75-108%). Notably, gold sublayers were associated with elevated IL-10 secretion by 72 h. Based on overall biological performance, Ag/Au heterostructures offering sustained antibacterial activity against planktonic bacteria, low cytotoxicity, and a cytokine profile that may be favorable for long-term integration are promising candidates for mesh implants. Also, h-Ag/Pt/TiS showed an optimal balance between rapid antibacterial action and biocompatibility and therefore appears to be a suitable candidate for further in vivo investigation.
SN  - 2079-4983
ER  -