Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 21 min ago
PreprintCC BY 4.0arXiv

Bayesian Image Reconstruction and Uncertainty Quantification for Three-Photon Positronium Ratio Imaging: Toward Radiotheranostic Applications

Abstract

Three-photon annihilation imaging can estimate positronium decay ratios with pure positron emitters, including the imaging agents of radiotheranostic pairs, but quantitative reconstruction is limited by heterogeneous localization errors, selection-dependent sensitivity, and background coincidences. We develop a Bayesian reconstruction combining a three-dimensional event-response model with a Poisson likelihood and latent signal-background allocations. Photon-energy and interaction-position uncertainties enter the event covariance; a simulation-calibrated scale mixture accommodates heavy-tailed errors. Posterior sampling gives credible intervals for the three-to-two-photon enhancement ratio. We compare kernel deposition, voxel MLEM, and matched regional maximum likelihood. At 3000 selected events in full-absorption simulation, the regional Bayesian estimator had ratio RMSE 0.067, versus 0.075 for kernel-deposition region-of-interest analysis. In a transport-based four-rod simulation without background, biases averaged at most 3.2% over six independent simulations, whereas background and detector mismatch degraded it. In a measured uniform phantom, the heavy-tailed regional model gave 1.02, 0.74, 1.02 for the 2, 3, 4 mm rods (5 mm reference; nominal 1). Matched regional maximum likelihood agreed with the Bayesian estimates in every simulated setting (bias differences within 0.15 points) and on the measured data (within 0.008), so gains derive from the regional likelihood. Under Poisson Kullback-Leibler loss, Gamma posterior means dominate maximum likelihood, appreciably only at small counts; horseshoe-type and smoothing priors changed voxel images but not regional ratios, whereas shrinking ratios across regions reduced error when regions shared a ratio. Posterior intervals quantify the uncertainty that treatment decisions require; calibration and background modeling remain limiting.

Related

  1. Uncertainty Quantification of Next Generation Reservoir Computing with Applications to Memory-Driven Dynamical Systems
    Livia Popa, Sumanta Basu, Martin T. Wells
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  2. Multi-Task Learning of Conditional Mean Operators: applications to dynamical systems and uncertainty quantification
    Sami Chemlal, Thibaut Germain, Rémi Flamary +2
    arXivPreprintCC BY 4.0Full textStatisticsarXiv
  3. Asymptotic-Preserving Tensor Neural Networks for 3D High-Field Kinetic Equations with Applications to Uncertainty Quantification
    Shi Jin, Tian-ai Zhang
    arXivPreprintarXiv licenceFull textNumerical analysis & scientific computingarXiv
  4. Adaptive Uncertainty Quantification on Simplicial Complexes with Conformalized Simplicial Neural Networks
    Lekun Wang, Jaidev Goel, Yulia R. Gel +1
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  5. Laplace approximation of the parameter posterior with embedded error for efficient uncertainty quantification of expensive model calibrations
    Reese E. Jones, Kyle N. Karlson, Matt W. Kury +2
    arXivPreprintCC BY 4.0Full textNumerical analysis & scientific computingarXiv
BibTeX
@misc{huang2026bayesian,
  title = {{Bayesian Image Reconstruction and Uncertainty Quantification for Three-Photon Positronium Ratio Imaging: Toward Radiotheranostic Applications}},
  author = {Hsin-Hsiung Huang and Macoto Fujimoto and Berkin Uluutku and Andres F. Torres and Kenji Shimazoe},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.28333},
  eprint = {2611.28333},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.28333},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Bayesian Image Reconstruction and Uncertainty Quantification for Three-Photon Positronium Ratio Imaging: Toward Radiotheranostic Applications
AU  - Hsin-Hsiung Huang
AU  - Macoto Fujimoto
AU  - Berkin Uluutku
AU  - Andres F. Torres
AU  - Kenji Shimazoe
PY  - 2026
DA  - 2026/11/20
PB  - arXiv
DO  - 10.48550/arxiv.2611.28333
UR  - https://arxiv.org/abs/2611.28333
AB  - Three-photon annihilation imaging can estimate positronium decay ratios with pure positron emitters, including the imaging agents of radiotheranostic pairs, but quantitative reconstruction is limited by heterogeneous localization errors, selection-dependent sensitivity, and background coincidences. We develop a Bayesian reconstruction combining a three-dimensional event-response model with a Poisson likelihood and latent signal-background allocations. Photon-energy and interaction-position uncertainties enter the event covariance; a simulation-calibrated scale mixture accommodates heavy-tailed errors. Posterior sampling gives credible intervals for the three-to-two-photon enhancement ratio. We compare kernel deposition, voxel MLEM, and matched regional maximum likelihood. At 3000 selected events in full-absorption simulation, the regional Bayesian estimator had ratio RMSE 0.067, versus 0.075 for kernel-deposition region-of-interest analysis. In a transport-based four-rod simulation without background, biases averaged at most 3.2% over six independent simulations, whereas background and detector mismatch degraded it. In a measured uniform phantom, the heavy-tailed regional model gave 1.02, 0.74, 1.02 for the 2, 3, 4 mm rods (5 mm reference; nominal 1). Matched regional maximum likelihood agreed with the Bayesian estimates in every simulated setting (bias differences within 0.15 points) and on the measured data (within 0.008), so gains derive from the regional likelihood. Under Poisson Kullback-Leibler loss, Gamma posterior means dominate maximum likelihood, appreciably only at small counts; horseshoe-type and smoothing priors changed voxel images but not regional ratios, whereas shrinking ratios across regions reduced error when regions shared a ratio. Posterior intervals quantify the uncertainty that treatment decisions require; calibration and background modeling remain limiting.
ER  -