Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 51 min ago
Peer-reviewedCC BY 4.0Scientific Reports

Bacterial contamination of semi-critical equipment in prehospital emergency ambulances in Ilam province, Iran: a descriptive survey with exploratory laboratory findings

Abstract

Given the working environment and conditions of prehospital emergency personnel and their contact with patients, the community, hospitals, and other healthcare workers, ambulance environments and equipment are prone to contamination and subsequent transmission to patients and the community. This study primarily aimed to describe bacterial contamination of semi-critical equipment in prehospital emergency ambulances in Ilam province, Iran. As an exploratory secondary component, growth-inhibitory activity of two commonly used disinfectants (Deconex 53 Plus and Sayasept HI) against the isolated organisms was assessed using a disk diffusion assay. This semi experimental study was conducted on semi-critical equipment in ambulances belonging to 30 emergency centers. Using convenience sampling, four semi-critical items (laryngoscopes, Magill forceps, oxygen masks and connectors, and AMBU bags) were randomly selected from each ambulance. Samples were collected by sterile swabs moistened with brain heartinfusion (BHI) broth from standardized high contact surfaces. Bacteria were identified by Gram staining, selective/differential media, and standard biochemical tests. As an exploratory analysis, susceptibility to 2% solutions of Sayasept HI and Deconex 53 Plus was assessed by the disk diffusion method on Mueller-Hinton agar. Statistical analysis was performed using SPSS version 25 (two-sided independent t-tests after normality assessment). A total of 120 samples were collected, of which 74 (61.7%) yielded positive cultures. Staphylococcus epidermidis was the most frequently isolated organism (31/120, 25.8% of all samples; 41.9% of positive cultures). The highest proportion of positive cultures among the four equipment types was observed for laryngoscopes (21/30, 70.0% of laryngoscopes; 28.4% of all positive cultures). In exploratory disk diffusion testing, the mean inhibition zone diameter produced by Deconex 53 Plus was larger than that produced by Sayasept HI for the overall set of isolates and across equipment types and organism groups (all p < 0.05). These findings must be interpreted strictly as laboratory growth-inhibition observations and do not constitute evidence of comparative practical disinfectant efficacy. Semi-critical equipment in the studied ambulances showed a substantial rate of bacterial contamination, predominantly by coagulase-negative staphylococci. The exploratory laboratory disk diffusion results (larger zones with Deconex 53 Plus) are influenced by both antimicrobial activity and diffusion characteristics of the active compounds and do not measure bactericidal efficacy under practical use conditions (organic load, contact time, surface material, etc.). Therefore, these in vitro findings alone do not justify prioritization of one product over the other for routine ambulance disinfection. Standardized bactericidal tests (e.g., according to EN 13727 / EN 14885) under simulated use conditions are required before any clinical recommendations regarding disinfectant selection can be made. The primary contribution of this study is the descriptive contamination data. Therefore, these in vitro findings alone do not justify prioritization of one product over the other for routine ambulance disinfection and should be regarded solely as exploratory laboratory observations.

Related

  1. Transport mechanical ventilation during cardiopulmonary resuscitation in out-of-hospital cardiac arrest: an exploratory prehospital pilot study
    Welawat Tienpratarn, Pariyakon Kusolthammarat, Chaiyaporn Yuksen +1
    BMC Emergency MedicinePeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  2. Prehospital qSOFA Is Associated with 30-Day Mortality Within Emergency Department Triage Strata in Ambulance-Transported Adults with Suspected Infection: An Exploratory Three-Year Retrospective Cohort Study
    Ayşenur Özçelik, Faruk Danış, Kaan Çelik
    Journal of clinical medicinePeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCCrossref
  3. Stress entropic load as an exploratory thermodynamic indicator of physiological activation during a laboratory gaming task
    Martin Sebera, Filip Zlámal, Lenka Svobodová +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicineCrossref
  4. Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study
    T. M. Axakali, M. A. Kouri, P. Georgakis +7
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyCrossref
  5. Characteristics of junior residents choosing alternative career pathways without entering traditional specialty residency programs: An exploratory descriptive study
    Koshi Ota, Kanna Ota
    SAGE Open MedicinePeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMCEurope PMC
BibTeX
@article{mirzaei2026bacterial,
  title = {{Bacterial contamination of semi-critical equipment in prehospital emergency ambulances in Ilam province, Iran: a descriptive survey with exploratory laboratory findings}},
  author = {Sousan Mirzaei and Abbas Maleki and Lida Menati and Nader Salari and Rostam Jalali},
  journal = {Scientific Reports},
  year = {2026},
  month = sep,
  doi = {10.1038/s41598-026-74218-8},
  url = {https://www.nature.com/articles/s41598-026-74218-8},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Bacterial contamination of semi-critical equipment in prehospital emergency ambulances in Ilam province, Iran: a descriptive survey with exploratory laboratory findings
AU  - Sousan Mirzaei
AU  - Abbas Maleki
AU  - Lida Menati
AU  - Nader Salari
AU  - Rostam Jalali
PY  - 2026
DA  - 2026/09/30
JO  - Scientific Reports
DO  - 10.1038/s41598-026-74218-8
UR  - https://www.nature.com/articles/s41598-026-74218-8
AB  - Given the working environment and conditions of prehospital emergency personnel and their contact with patients, the community, hospitals, and other healthcare workers, ambulance environments and equipment are prone to contamination and subsequent transmission to patients and the community. This study primarily aimed to describe bacterial contamination of semi-critical equipment in prehospital emergency ambulances in Ilam province, Iran. As an exploratory secondary component, growth-inhibitory activity of two commonly used disinfectants (Deconex 53 Plus and Sayasept HI) against the isolated organisms was assessed using a disk diffusion assay. This semi experimental study was conducted on semi-critical equipment in ambulances belonging to 30 emergency centers. Using convenience sampling, four semi-critical items (laryngoscopes, Magill forceps, oxygen masks and connectors, and AMBU bags) were randomly selected from each ambulance. Samples were collected by sterile swabs moistened with brain heartinfusion (BHI) broth from standardized high contact surfaces. Bacteria were identified by Gram staining, selective/differential media, and standard biochemical tests. As an exploratory analysis, susceptibility to 2% solutions of Sayasept HI and Deconex 53 Plus was assessed by the disk diffusion method on Mueller-Hinton agar. Statistical analysis was performed using SPSS version 25 (two-sided independent t-tests after normality assessment). A total of 120 samples were collected, of which 74 (61.7%) yielded positive cultures. Staphylococcus epidermidis was the most frequently isolated organism (31/120, 25.8% of all samples; 41.9% of positive cultures). The highest proportion of positive cultures among the four equipment types was observed for laryngoscopes (21/30, 70.0% of laryngoscopes; 28.4% of all positive cultures). In exploratory disk diffusion testing, the mean inhibition zone diameter produced by Deconex 53 Plus was larger than that produced by Sayasept HI for the overall set of isolates and across equipment types and organism groups (all p < 0.05). These findings must be interpreted strictly as laboratory growth-inhibition observations and do not constitute evidence of comparative practical disinfectant efficacy. Semi-critical equipment in the studied ambulances showed a substantial rate of bacterial contamination, predominantly by coagulase-negative staphylococci. The exploratory laboratory disk diffusion results (larger zones with Deconex 53 Plus) are influenced by both antimicrobial activity and diffusion characteristics of the active compounds and do not measure bactericidal efficacy under practical use conditions (organic load, contact time, surface material, etc.). Therefore, these in vitro findings alone do not justify prioritization of one product over the other for routine ambulance disinfection. Standardized bactericidal tests (e.g., according to EN 13727 / EN 14885) under simulated use conditions are required before any clinical recommendations regarding disinfectant selection can be made. The primary contribution of this study is the descriptive contamination data. Therefore, these in vitro findings alone do not justify prioritization of one product over the other for routine ambulance disinfection and should be regarded solely as exploratory laboratory observations.
SN  - 2045-2322
ER  -