Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study
4 affiliations
- 1Radiation Physics Materials Technology and Biomedical Imaging Laboratory (ΑΚΤΥΒΑ), Department of Biomedical Engineering, University of West Attica, Egaleo
- 2Medical Physics, General Hospital GHA Korgialeneio Mpenakeio-Hellenic Red Cross
- 3Medical Physics Unit, 2nd Department of Radiology, Medical School, National and Kapodistrian University of Athens
- 4Αnesthesiologists’ Department, General Hospital GHA Korgialeneio Mpenakeio-Hellenic Red Cross
Abstract
Anesthesia personnel participating in fluoroscopy-guided interventions are routinely exposed to ionizing radiation; however, their occupational radiation burden remains insufficiently characterized. This single-center descriptive and exploratory study investigated occupational ionizing radiation exposure among anesthesiology personnel using real-time personal dosimetry. A total of 134 procedures across multiple interventional specialties were evaluated using the HERADO radiation management platform and ALMAR active personal dosimeters. Mean over-apron personal dose equivalent Hp(10) ranged from 0.010 ± 0.009 mSv to 0.025 ± 0.011 mSv per procedure. Descriptive differences in occupational exposure were observed across procedural categories; however, these differences should not be attributed independently to procedural category because relevant technical, geometric, shielding, and workflow factors were not fully quantified. The findings demonstrate the value of real-time personal dosimetry for procedure-level characterization of occupational exposure and may inform radiation-protection strategies in fluoroscopy-guided clinical practice.
Related
- Training and Assessment of Non-Technical Human Factor Skills Among Anesthesiology Residents: An Exploratory Educational Quality Improvement Initiative.
- Speech- and Text-Based Emotion Recognition in Anesthesiology Residents During Critical Incident Simulation Training: Exploratory Observational Study.
- Occupational asbestos exposure and lung cancer: contemporary research trends, exploratory genetic evidence, and global burden from 1990 to 2021
- Incidence and Demographic, Clinical, and Occupational Patterns of Dental Caries and Gingivitis in Workers: A Retrospective Descriptive Cohort Study
- Effects of Occupational Therapy Interventions on Occupational Performance and Physical and Cognitive Fatigue in Adults with Multiple Sclerosis: A Systematic Review of Randomized Controlled Trials
BibTeX
@article{axakali2026realtime,
title = {{Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study}},
author = {T. M. Axakali and M. A. Kouri and P. Georgakis and E. Bournaki and V. Tanou and E. Kounadi and C. Michail and N. Kalyvas and I. Valais and G. Fountos},
journal = {Frontiers in Public Health},
year = {2026},
month = oct,
doi = {10.3389/fpubh.2026.1924968},
url = {https://www.frontiersin.org/articles/10.3389/fpubh.2026.1924968/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study
AU - T. M. Axakali
AU - M. A. Kouri
AU - P. Georgakis
AU - E. Bournaki
AU - V. Tanou
AU - E. Kounadi
AU - C. Michail
AU - N. Kalyvas
AU - I. Valais
AU - G. Fountos
PY - 2026
DA - 2026/10/28
JO - Frontiers in Public Health
DO - 10.3389/fpubh.2026.1924968
UR - https://www.frontiersin.org/articles/10.3389/fpubh.2026.1924968/full
AB - Anesthesia personnel participating in fluoroscopy-guided interventions are routinely exposed to ionizing radiation; however, their occupational radiation burden remains insufficiently characterized. This single-center descriptive and exploratory study investigated occupational ionizing radiation exposure among anesthesiology personnel using real-time personal dosimetry. A total of 134 procedures across multiple interventional specialties were evaluated using the HERADO radiation management platform and ALMAR active personal dosimeters. Mean over-apron personal dose equivalent Hp(10) ranged from 0.010 ± 0.009 mSv to 0.025 ± 0.011 mSv per procedure. Descriptive differences in occupational exposure were observed across procedural categories; however, these differences should not be attributed independently to procedural category because relevant technical, geometric, shielding, and workflow factors were not fully quantified. The findings demonstrate the value of real-time personal dosimetry for procedure-level characterization of occupational exposure and may inform radiation-protection strategies in fluoroscopy-guided clinical practice.
SN - 2296-2565
ER -