Monitoring Advanced Hydration Station (AHS) Water Quality in Flint, MI, School Buildings: Field Grab Sampling and Filter-Based Lead Assessment
4 affiliations
- 1Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, Missouri 63150, United States
- 2Department of Mechanical Engineering, Kettering University, Flint, Michigan 48504, United States
- 3Department of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- 4Department of Civil and Environmental Engineering, Wayne State University, Detroit, Michigan 48202, United States
Abstract
School drinking water lead exposure remains a public health concern. In addition, time-variant lead concentrations pose challenges to monitoring practices. This study evaluates the lead (and, for some experiments, bacterial) removal performance of advanced hydration stations (AHS) with membrane filters, activated carbon block filters, and LED UV disinfection in Flint, Michigan. Laboratory challenge testing and more than 400 grab samples were collected from influent and effluent water from over 70 field-deployed AHS units during three sampling campaigns in 2022 and 2023. Our study confirmed that AHS units effectively removed lead. The median influent lead concentrations ranged from 6 to 14 μg/L, with 53% of samples exceeding 10 μg/L. Lead levels in effluent water were almost all below the detection limit (98% of samples). Effluent bacteria concentrations monitored during the first field sampling campaign in 2022 were all below detection, and removal during challenge testing were >2.6 log reduction. A subset of filters (n = 21) from those harvested in July 2022 were acid-extracted to assess the total accumulation of lead. This information, along with the cumulative volume of water processed, was used to calculate a volume-averaged lead concentration that represents avoided lead exposure and identifies potential hot spots of lead release to prioritize remediation activities. The outcomes of this monitoring campaign demonstrate the effectiveness of the AHS units at removing lead and bacteria, and the importance of using filter-based monitoring to inform AHS maintenance and identify upstream sources of lead.
Related
- Fire risk assessment for high-rise buildings based on Integrated Disaster Risk Theory
- Reply to Marciano and Rossiter: Balancing muscle oxygen consumption sampling and slope quality in NIRS‐derived assessment of muscle oxidative capacity
- From Catheters to Wearables: Advanced Hemodynamic Monitoring and the Emerging Role of PPG‐Based Devices
- Cross-Source Progression Assessment in Advanced Pancreatic Cancer: An Opportunity-Adjusted Six-State Analysis
- Integrating ctDNA-based ESR1m monitoring into first-line care for ER+, HER2- advanced breast cancer: a consensus workflow.
BibTeX
@article{wang2026monitoring,
title = {{Monitoring Advanced Hydration Station (AHS) Water Quality in Flint, MI, School Buildings: Field Grab Sampling and Filter-Based Lead Assessment}},
author = {Zehua Wang and Laura Sullivan and Michelle Ammerman and Jean M. Brownell and Anushka Mishrra and Conor Gowan and Shawn P. McElmurry and Daniel E. Giammar and Nancy G. Love},
journal = {Environmental Science \& Technology},
year = {2026},
month = oct,
doi = {10.1021/acs.est.6c09190},
url = {https://doi.org/10.1021/acs.est.6c09190},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Monitoring Advanced Hydration Station (AHS) Water Quality in Flint, MI, School Buildings: Field Grab Sampling and Filter-Based Lead Assessment
AU - Zehua Wang
AU - Laura Sullivan
AU - Michelle Ammerman
AU - Jean M. Brownell
AU - Anushka Mishrra
AU - Conor Gowan
AU - Shawn P. McElmurry
AU - Daniel E. Giammar
AU - Nancy G. Love
PY - 2026
DA - 2026/10/23
JO - Environmental Science & Technology
DO - 10.1021/acs.est.6c09190
UR - https://doi.org/10.1021/acs.est.6c09190
AB - School drinking water lead exposure remains a public health concern. In addition, time-variant lead concentrations pose challenges to monitoring practices. This study evaluates the lead (and, for some experiments, bacterial) removal performance of advanced hydration stations (AHS) with membrane filters, activated carbon block filters, and LED UV disinfection in Flint, Michigan. Laboratory challenge testing and more than 400 grab samples were collected from influent and effluent water from over 70 field-deployed AHS units during three sampling campaigns in 2022 and 2023. Our study confirmed that AHS units effectively removed lead. The median influent lead concentrations ranged from 6 to 14 μg/L, with 53% of samples exceeding 10 μg/L. Lead levels in effluent water were almost all below the detection limit (98% of samples). Effluent bacteria concentrations monitored during the first field sampling campaign in 2022 were all below detection, and removal during challenge testing were >2.6 log reduction. A subset of filters (n = 21) from those harvested in July 2022 were acid-extracted to assess the total accumulation of lead. This information, along with the cumulative volume of water processed, was used to calculate a volume-averaged lead concentration that represents avoided lead exposure and identifies potential hot spots of lead release to prioritize remediation activities. The outcomes of this monitoring campaign demonstrate the effectiveness of the AHS units at removing lead and bacteria, and the importance of using filter-based monitoring to inform AHS maintenance and identify upstream sources of lead.
SN - 0013-936X
SN - 1520-5851
ER -