Skip to content
DraconiticResearch
Search Sources API
190,860 studies31 sourcesUpdated 33 min ago
Peer-reviewedCC BYTranslational vision science & technology

Preclinical Safety and Feasibility Study of Line-Field Confocal Optical Coherence Tomography for Ophthalmology Applications

Abstract

Purpose: The purpose of this study was to demonstrate the first use of a commercially available, CE-marked line-field confocal optical coherence tomography (LC-OCT) in ophthalmology and assess its safety and feasibility for ocular imaging in rabbits, focusing on phototoxicity and tissue integrity. Methods: Five 14-week-old New Zealand White rabbits underwent corneal imaging using the DeepLive device (DAMAE Medical, Paris, France), originally developed for dermatologic applications. Imaging sessions lasted 5 to 10 minutes per eye, using illumination at a center wavelength of 820 nm and a power of 13.2 mW. Safety was evaluated in silico according to International Electrotechnical Commission (IEC) 60825-1 standards and in vivo through clinical assessments including slit-lamp examination, retinal imaging, and intraocular pressure (IOP) measurements at baseline, immediately after imaging, and on days 7 and 14. Histological analysis was performed day 14. Results: LC-OCT provided high-resolution three-dimensional imaging of the cornea (1.2 × 0.5 × 0.5 mm) and two-dimensional views of corneal layers, conjunctiva, and the nictitating membrane, revealing cellular details. In silico analysis confirmed that laser exposure remained below IEC safety limits. In vivo evaluations showed no corneal opacity, neovascularization, inflammation, or retinal alterations at any time point. Lens transparency remained normal (Lens Opacities Classification System [LOCS] III grade = 0), and IOP showed no treatment-related differences (P = 0.6713). Histology confirmed preservation of corneal and retinal structures. Conclusions: Ophthalmologic use of CE-marked LC-OCT demonstrated safe, effective imaging in rabbits without phototoxicity, supporting its potential for clinical ophthalmic applications. Translational Relevance: These findings provide preclinical safety evidence supporting LC-OCT as a noninvasive, high-resolution imaging modality for future clinical ophthalmology applications.

Related

  1. Spatial coherence governs the resolution–signal trade-off and aberration tolerance in full-field optical coherence tomography
    Inès Loukili, Arthur Sureau, Laurent Mugnier +4
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  2. Numerical speckle reduction for optical coherence tomography based on an analytical image formation model
    Xibo Wang, Shuichi Makita, Nobuhisa Tateno +6
    arXivPreprintCC BY-SA 4.0Full textOptics & photonicsarXiv
  3. Spatially or temporally resolved phase-based optoretinography with actively-tracked point-scanning optical coherence tomography
    Léo Puyo, Jonas Franke, Felix Zeisberger +2
    arXivPreprintarXiv licenceFull textBiological & medical physicsOptics & photonicsarXiv
  4. Fully Fiber-Integrated 3D-Printed Probes for Plug-and-Play Endoscopic Optical Coherence Tomography
    Yihan Wang, Ruilin You, Jiabin Chen +5
    arXivPreprintarXiv licenceFull textBiological & medical physicsOptics & photonicsarXiv
  5. Digital confocal imaging in holographic optical coherence tomography at high space-bandwidth product
    N. P. Klooster, S. A. Thakur, F. Zeisberger +4
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationBiological & medical physicsarXiv
BibTeX
@article{crouzet2026preclinical,
  title = {{Preclinical Safety and Feasibility Study of Line-Field Confocal Optical Coherence Tomography for Ophthalmology Applications}},
  author = {Emmanuel Crouzet and Jonas Ogien and Jean-Marc Dumollard and Chantal Perrache and Jean-Luc Perrot and Philippe Gain and Arnaud Dubois and Gilles Thuret},
  journal = {Translational vision science \& technology},
  year = {2026},
  month = jul,
  doi = {10.1167/tvst.15.7.1},
  url = {https://iogs.hal.science/hal-05773915v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Preclinical Safety and Feasibility Study of Line-Field Confocal Optical Coherence Tomography for Ophthalmology Applications
AU  - Emmanuel Crouzet
AU  - Jonas Ogien
AU  - Jean-Marc Dumollard
AU  - Chantal Perrache
AU  - Jean-Luc Perrot
AU  - Philippe Gain
AU  - Arnaud Dubois
AU  - Gilles Thuret
PY  - 2026
DA  - 2026/07/01
JO  - Translational vision science & technology
DO  - 10.1167/tvst.15.7.1
UR  - https://iogs.hal.science/hal-05773915v1
AB  - Purpose: The purpose of this study was to demonstrate the first use of a commercially available, CE-marked line-field confocal optical coherence tomography (LC-OCT) in ophthalmology and assess its safety and feasibility for ocular imaging in rabbits, focusing on phototoxicity and tissue integrity. Methods: Five 14-week-old New Zealand White rabbits underwent corneal imaging using the DeepLive device (DAMAE Medical, Paris, France), originally developed for dermatologic applications. Imaging sessions lasted 5 to 10 minutes per eye, using illumination at a center wavelength of 820 nm and a power of 13.2 mW. Safety was evaluated in silico according to International Electrotechnical Commission (IEC) 60825-1 standards and in vivo through clinical assessments including slit-lamp examination, retinal imaging, and intraocular pressure (IOP) measurements at baseline, immediately after imaging, and on days 7 and 14. Histological analysis was performed day 14. Results: LC-OCT provided high-resolution three-dimensional imaging of the cornea (1.2 × 0.5 × 0.5 mm) and two-dimensional views of corneal layers, conjunctiva, and the nictitating membrane, revealing cellular details. In silico analysis confirmed that laser exposure remained below IEC safety limits. In vivo evaluations showed no corneal opacity, neovascularization, inflammation, or retinal alterations at any time point. Lens transparency remained normal (Lens Opacities Classification System [LOCS] III grade = 0), and IOP showed no treatment-related differences (P = 0.6713). Histology confirmed preservation of corneal and retinal structures. Conclusions: Ophthalmologic use of CE-marked LC-OCT demonstrated safe, effective imaging in rabbits without phototoxicity, supporting its potential for clinical ophthalmic applications. Translational Relevance: These findings provide preclinical safety evidence supporting LC-OCT as a noninvasive, high-resolution imaging modality for future clinical ophthalmology applications.
SN  - 2164-2591
ER  -