Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated 25 min ago
Peer-reviewedCC BY-NC-NDReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology

Comparison of extended kV-CBCT image quality between conventional and O-ring linear accelerators.

6 affiliations
  1. 1Center of Radiotherapy, National Institute of Oncology, Budapest, Hungary.
  2. 2Doctoral School of Physical Sciences, Budapest University of Technology and Economics, Budapest, Hungary.
  3. 3Doctoral College, Semmelweis University, Budapest, Hungary.
  4. 4Department of Oncology, Semmelweis University, Budapest, Hungary.
  5. 5Department of Molecular Immunology and Toxicology, National Tumor Biology Laboratory, National Institute of Oncology, Budapest, Hungary.
  6. 6Institute of Nuclear Techniques, Budapest University of Technology and Economics, Budapest, Hungary.

Abstract

In cases of non-central or large tumours, the use of an extended field of view is important for patient positioning or adaptive treatment. The aim of our study was to investigate the longitudinal and lateral consistency of extended kilovoltage cone-beam CT (kV-CBCT) image quality over the entire scan length. The study compared extended kV-CBCT image quality between conventional and O-ring linear accelerators (LINACs) using image quality phantoms. The impact of lateral and longitudinal phantom offsets was analysed across the reconstruction algorithms [filtered back projection - Feldkamp-Davis-Kress (FDK) and iterative cone-beam computed tomography (iCBCT)] and imaging protocols. The CT calibration curves showed consistent alignment across LINACs, imaging protocols, longitudinal displacements, and reconstruction algorithms. The average mean difference in the CT numbers measured during longitudinal shifts, averaged over the other material inserts, was 37 ± 15 Hounsfield units (HU). In the homogeneity examination, the lateral inserts displayed signal reductions as they moved away from the isocentre. For an imaging protocol on a ring accelerator, the central insert remained near 8 HU, while the signal of lateral inserts located 20 cm from the isocentre decreased from 0 HU to -160 HU. Our results show that the longitudinal extension does not affect image linearity, making extended CBCT protocols suitable for long target volumes. CBCT-based adaptation may be unsuitable for large lateral or peripheral tumours due to poor image quality. Consequently, the generation of synthetic CTs from peripheral regions of CBCT images should be approached with caution.

Related

  1. Dosimetric Comparison of Functional Radiosurgery Treatments for Trigeminal Neuralgia, Essential Tremor, and Obsessive-compulsive Disorder Using Gamma Knife, CyberKnife, and Linear Accelerators
    Carlos Daniel Venencia, Crystian Wilian Chagas Saraiva, Gabriela Reis dos Santos de Jesus
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  2. Closing the gap: A two-site MLC matching study for Varian TrueBeam Linear Accelerators
    Michael Douglass, Corey Bridger, Mitchell Herrick +4
    arXivPreprintCC BY 4.0Full textBiological & medical physicsarXiv
  3. Commissioning of Medical Linear Accelerators in India: A Survey of Regulatory Compliance, Clinical Implementation, and Professional Challenges
    R. C. Muhammed Anaz, Shrikant Kale, Ritu Raj Upreti +8
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  4. Robust enhanced leaf model implementation for beam-matched linear accelerators: Impact of physical leaf gap variations.
    Soyoung Lee, Paulina E Galavis, Siyoung Jang
    Journal of applied clinical medical physicsPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMCPMC
  5. Linear-response TDDFT simulations of K-edge resonant inelastic X-ray scattering in extended systems
    Beliz Sertcan Gökmen, Michael R. Coates, Jürg Hutter +1
    ChemRxivPreprintCC BYFull textApplied physics & instrumentationChemRxiv
BibTeX
@article{gazdaghegyesi2026comparison,
  title = {{Comparison of extended kV-CBCT image quality between conventional and O-ring linear accelerators.}},
  author = {Szilvia Gazdag-Hegyesi and Ádám Gáldi and Tibor Major and Csilla Pesznyák},
  journal = {Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology},
  year = {2026},
  month = nov,
  doi = {10.5603/rpor.113323},
  url = {https://europepmc.org/article/MED/42997863},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Comparison of extended kV-CBCT image quality between conventional and O-ring linear accelerators.
AU  - Szilvia Gazdag-Hegyesi
AU  - Ádám Gáldi
AU  - Tibor Major
AU  - Csilla Pesznyák
PY  - 2026
DA  - 2026/11/01
JO  - Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology
DO  - 10.5603/rpor.113323
UR  - https://europepmc.org/article/MED/42997863
AB  - In cases of non-central or large tumours, the use of an extended field of view is important for patient positioning or adaptive treatment. The aim of our study was to investigate the longitudinal and lateral consistency of extended kilovoltage cone-beam CT (kV-CBCT) image quality over the entire scan length. The study compared extended kV-CBCT image quality between conventional and O-ring linear accelerators (LINACs) using image quality phantoms. The impact of lateral and longitudinal phantom offsets was analysed across the reconstruction algorithms [filtered back projection - Feldkamp-Davis-Kress (FDK) and iterative cone-beam computed tomography (iCBCT)] and imaging protocols. The CT calibration curves showed consistent alignment across LINACs, imaging protocols, longitudinal displacements, and reconstruction algorithms. The average mean difference in the CT numbers measured during longitudinal shifts, averaged over the other material inserts, was 37 ± 15 Hounsfield units (HU). In the homogeneity examination, the lateral inserts displayed signal reductions as they moved away from the isocentre. For an imaging protocol on a ring accelerator, the central insert remained near 8 HU, while the signal of lateral inserts located 20 cm from the isocentre decreased from 0 HU to -160 HU. Our results show that the longitudinal extension does not affect image linearity, making extended CBCT protocols suitable for long target volumes. CBCT-based adaptation may be unsuitable for large lateral or peripheral tumours due to poor image quality. Consequently, the generation of synthetic CTs from peripheral regions of CBCT images should be approached with caution.
SN  - 1507-1367
SN  - 2083-4640
ER  -