Skip to content
DraconiticResearch
Search Sources API
224,311 studies31 sourcesUpdated 56 min ago
Peer-reviewedCC BY 4.0Frontiers in Medicine

Structured auscultation evidence modeling for multi-protocol respiratory sound classification

4 affiliations
  1. 1Department of Respiratory and Critical Care Medicine, Shanghai Changzheng Hospital, Naval Medical University, Shanghai, China
  2. 2Department of Bioinformatics, Center for Translational Medicine, Naval Medical University, Shanghai, China
  3. 3Department of Dermatology, Shanghai Changzheng Hospital, Naval Medical University, Shanghai, China
  4. 4Department of Thoracic Surgery, Shanghai Changhai Hospital, Naval Medical University, Shanghai, China

Abstract

Introduction: Digitally recorded respiratory sounds provide a practical source of physiological information for computer-assisted auscultation. Their acoustic presentation varies across subjects, recording locations, devices, filtering conditions, and environmental noise. Most classification models map acoustic representations directly to disease labels, which provides limited access to the auscultation findings associated with each prediction. This study investigated whether respiratory acoustic representations could be organized into structured evidence for classification across different label settings and evaluation levels.

Methods: We developed Evi-CARD to organize respiratory sound representations into structured evidence for classification. A frozen Open Respiratory Acoustic Foundation Model (OPERA) encodes overlapping 8s segments, from which a concept-aligned pathway estimates wheeze, crackle, inspiration, and expiration together with learned evidence weights. An attention-constrained residual pathway preserves complementary acoustic information, although its attention ceiling does not strictly bound the residual pathway’s contribution to the final logits. Separate disease-query layers adapt the shared evidence representation to each classification setting. We assessed BRACETS A2 and A3 by subject-independent five-fold validation at the recording level and KAUH-primary by subject-independent five-fold validation at the patient level for Healthy vs. Obstructive classification. Each assessment was conducted within its source cohort and was not an external-validation experiment.

Results: On BRACETS, Evi-CARD achieved balanced accuracies of 77.8% for the A2 three-class task and 70.2% for the more granular A3 five-class task. On KAUH-primary, pooled patient-level out-of-fold evaluation yielded an area under the receiver operating characteristic curve of 95.1%, a balanced accuracy of 88.0%, a Macro F1 of 88.1%, and an expected calibration error of 5.1%. Across HF_Lung_V1, SPRSound, and ICBHI, the complete concept layer also provided more accurate and better-calibrated concept predictions than the evaluated acoustic-probe and concept-readout baselines.

Discussion: These findings show that protocol-specific respiratory sound classification can be based on concept-associated latent evidence while retaining a constrained route for information outside the predefined concept set. However, Evi-CARD is not a strict scalar concept bottleneck, and no clinical meaning is assigned to its residual-memory slots. The evidence is limited to within-cohort cross-validation; independent-cohort testing, device- and site-stratified evaluation, and clinician review remain necessary before considering clinical deployment.

Related

  1. Identification of adventitious lung sounds in children with respiratory illnesses in Bangladesh using artificial intelligence and digital auscultation
    Salahuddin Ahmed, Ahad Mahmud Khan, Harish Nair +17
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossref
  2. Enhancing Evidence Translation Through Structured Clinical Reasoning: A Mixed-Methods Controlled Feasibility Study of Peer Visibility and Readiness Mechanisms in Applied Learning
    Caroline O. Pardo, Nancy Paynter, Edith Perez
    Journal of CMEPeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  3. Physiologically Informed Digital Auscultation for Pneumonia Detection in Long-term Care Residents
    Nicholas Rasmussen, Oleg Zaslavsky, Zih-Ling Wang +5
    arXivPreprintCC BY 4.0Full textPhysiologyarXiv
  4. Evidence quality assessment of traditional Chinese medicine and integrated traditional Chinese and Western medicine for acute upper respiratory infection in children: an umbrella review of systematic reviews and meta-analyses
    Zhen Liu, Yumeng Yang, Yuetong Liu +4
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Clinical outcome implications of novel auscultation device of artificial intelligence (NAVI-HF) in predischarge acute heart failure patients
    Rony Marethianto Santoso, Ser Wee, Amiliana Mardiani Soesanto +6
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossrefDOAJEurope PMC
BibTeX
@article{yuan2026structured,
  title = {{Structured auscultation evidence modeling for multi-protocol respiratory sound classification}},
  author = {Yuan Yuan and Qi Zhang and Yinuo Liu and Yang Chen and Xiaowei Wang},
  journal = {Frontiers in Medicine},
  year = {2026},
  month = oct,
  doi = {10.3389/fmed.2026.1987793},
  url = {https://doi.org/10.3389/fmed.2026.1987793},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Structured auscultation evidence modeling for multi-protocol respiratory sound classification
AU  - Yuan Yuan
AU  - Qi Zhang
AU  - Yinuo Liu
AU  - Yang Chen
AU  - Xiaowei Wang
PY  - 2026
DA  - 2026/10/21
JO  - Frontiers in Medicine
DO  - 10.3389/fmed.2026.1987793
UR  - https://doi.org/10.3389/fmed.2026.1987793
AB  - Introduction: Digitally recorded respiratory sounds provide a practical source of physiological information for computer-assisted auscultation. Their acoustic presentation varies across subjects, recording locations, devices, filtering conditions, and environmental noise. Most classification models map acoustic representations directly to disease labels, which provides limited access to the auscultation findings associated with each prediction. This study investigated whether respiratory acoustic representations could be organized into structured evidence for classification across different label settings and evaluation levels.  Methods: We developed Evi-CARD to organize respiratory sound representations into structured evidence for classification. A frozen Open Respiratory Acoustic Foundation Model (OPERA) encodes overlapping 8s segments, from which a concept-aligned pathway estimates wheeze, crackle, inspiration, and expiration together with learned evidence weights. An attention-constrained residual pathway preserves complementary acoustic information, although its attention ceiling does not strictly bound the residual pathway’s contribution to the final logits. Separate disease-query layers adapt the shared evidence representation to each classification setting. We assessed BRACETS A2 and A3 by subject-independent five-fold validation at the recording level and KAUH-primary by subject-independent five-fold validation at the patient level for Healthy vs. Obstructive classification. Each assessment was conducted within its source cohort and was not an external-validation experiment.  Results: On BRACETS, Evi-CARD achieved balanced accuracies of 77.8% for the A2 three-class task and 70.2% for the more granular A3 five-class task. On KAUH-primary, pooled patient-level out-of-fold evaluation yielded an area under the receiver operating characteristic curve of 95.1%, a balanced accuracy of 88.0%, a Macro F1 of 88.1%, and an expected calibration error of 5.1%. Across HF_Lung_V1, SPRSound, and ICBHI, the complete concept layer also provided more accurate and better-calibrated concept predictions than the evaluated acoustic-probe and concept-readout baselines.  Discussion: These findings show that protocol-specific respiratory sound classification can be based on concept-associated latent evidence while retaining a constrained route for information outside the predefined concept set. However, Evi-CARD is not a strict scalar concept bottleneck, and no clinical meaning is assigned to its residual-memory slots. The evidence is limited to within-cohort cross-validation; independent-cohort testing, device- and site-stratified evaluation, and clinician review remain necessary before considering clinical deployment.
SN  - 2296-858X
ER  -