Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 24 min ago
Peer-reviewedCC BYJournal of cardiovascular development and disease

Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages.

6 affiliations
  1. 1Department of Anesthesiology, Massachusetts General Hospital, Boston, MA 02114, USA.
  2. 2Harvard Medical School, Boston, MA 02115, USA.
  3. 3Department of Computer Science, Donald Bren School of Information and Computer Sciences, University of California, Irvine, Irvine, CA 92697, USA.
  4. 4Sue and Bill Gross School of Nursing, University of California, Irvine, Irvine, CA 92697, USA.
  5. 5Department of Medicine, Massachusetts General Hospital, Boston, MA 02114, USA.
  6. 6Broad Institute, Cambridge, MA 02142, USA.

Abstract

Wearable pulse metrics are typically reported as a single daily, waking, or nightly average. This presentation of the data may mask differences between sleep and wakefulness, temporal variations within a given state, and differences in the amount of signal retained. To determine whether single-value averages provide a representative summary of free-living pulse physiology, we analyzed 28 days of smartwatch and smart-ring data from 35 participants. Sleep and waking periods were identified using the smart-ring sleep data. Pulse rate was obtained from the smartwatch-generated values, and pulse rate variability (PRV) was calculated from the raw photoplethysmography as the root mean square of successive pulse-interval differences (RMSSD) and standard deviation of pulse-to-pulse intervals (SDNN). Analyses compared paired sleep-wake periods and examined temporal variability within both waking and sleep periods. Mean pulse rate was 72.4 beats/min during sleep and 89.1 beats/min during the subsequent waking period (difference: -16.7 beats/min; 95% confidence interval [CI], -23.0 to -10.2). The mean absolute deviation of the five-minute waking pulse-rate measurements from the waking-period mean was 10.89 beats/min (95% CI, 9.75-12.02); on average, 44.6% of waking measurements differed from the mean by more than 10 beats/min. During sleep, the mean absolute deviation from the period mean was 4.30 beats/min (95% CI, 3.17-5.56). From earlier to later sleep, RMSSD increased by 40.8% (95% CI, 18.7-67.5%; q = 0.0001) and SDNN increased by 82.6% (95% CI, 51.4-117.4%; q = 0.0001). Only 8.6% of the waking recordings met the PRV quality criteria, whereas 64.0% of the sleep recordings did. In summary, single-value averages may not capture differences between sleep and wakefulness or temporal structure within states; unequal signal retention may also affect the representativeness of state averages. Therefore, reports of wearable pulse biomarkers should specify sleep-wake state, within-state timing, aggregation method, and signal retention criteria.

Related

  1. Nightly Sleep and Next-Day Physical Activity Structure and Volume: Within-Individual Associations in 81 537 Adults.
    Li Yutao, Song Hengguo
    Scandinavian journal of medicine & science in sportsPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  2. Wearable-measured 24-hour heart rate variability and neovascular age-related macular degeneration: a cross-sectional study
    D.-W. Park
    medRxivPreprintAll rights reservedFull textGeneral medicinemedRxiv
  3. Wearable Heart Rate Variability Monitoring, Autonomic Dysfunction and Post-exertional Malaise in Long COVID: An Observational Study
    Twan M. Ruijgt, Anouk Slaghekke, Anneke Ellens +2
    Sports Medicine (Auckland, N.z.)Peer-reviewedCC BY 4.0Full text8 citedNeurologyPMC
  4. Feasibility of Wearable Heart Rate Variability Monitoring During a Military Closed-Circuit Rebreather Dive: An Exploratory Case Report.
    Enrico Moccia, Vincenzo Lionetti, Gabriele Lombardi +6
    Journal of functional morphology and kinesiologyPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  5. Association between the freezing of gait questionnaire score and wearable sensor-derived stride-length variability in Parkinson’s disease
    Jienan Zhu, Chenxi Li, Liguo Dong +2
    Frontiers in NeurologyPeer-reviewedCC BY 4.0NeurologyCrossref
BibTeX
@article{cai2026temporal,
  title = {{Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages.}},
  author = {Ruixue Cai and Amir Rahmani and Shahab Haghayegh},
  journal = {Journal of cardiovascular development and disease},
  year = {2026},
  month = nov,
  doi = {10.3390/jcdd13110589},
  url = {https://europepmc.org/article/MED/43083096},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages.
AU  - Ruixue Cai
AU  - Amir Rahmani
AU  - Shahab Haghayegh
PY  - 2026
DA  - 2026/11/13
JO  - Journal of cardiovascular development and disease
DO  - 10.3390/jcdd13110589
UR  - https://europepmc.org/article/MED/43083096
AB  - Wearable pulse metrics are typically reported as a single daily, waking, or nightly average. This presentation of the data may mask differences between sleep and wakefulness, temporal variations within a given state, and differences in the amount of signal retained. To determine whether single-value averages provide a representative summary of free-living pulse physiology, we analyzed 28 days of smartwatch and smart-ring data from 35 participants. Sleep and waking periods were identified using the smart-ring sleep data. Pulse rate was obtained from the smartwatch-generated values, and pulse rate variability (PRV) was calculated from the raw photoplethysmography as the root mean square of successive pulse-interval differences (RMSSD) and standard deviation of pulse-to-pulse intervals (SDNN). Analyses compared paired sleep-wake periods and examined temporal variability within both waking and sleep periods. Mean pulse rate was 72.4 beats/min during sleep and 89.1 beats/min during the subsequent waking period (difference: -16.7 beats/min; 95% confidence interval [CI], -23.0 to -10.2). The mean absolute deviation of the five-minute waking pulse-rate measurements from the waking-period mean was 10.89 beats/min (95% CI, 9.75-12.02); on average, 44.6% of waking measurements differed from the mean by more than 10 beats/min. During sleep, the mean absolute deviation from the period mean was 4.30 beats/min (95% CI, 3.17-5.56). From earlier to later sleep, RMSSD increased by 40.8% (95% CI, 18.7-67.5%; q = 0.0001) and SDNN increased by 82.6% (95% CI, 51.4-117.4%; q = 0.0001). Only 8.6% of the waking recordings met the PRV quality criteria, whereas 64.0% of the sleep recordings did. In summary, single-value averages may not capture differences between sleep and wakefulness or temporal structure within states; unequal signal retention may also affect the representativeness of state averages. Therefore, reports of wearable pulse biomarkers should specify sleep-wake state, within-state timing, aggregation method, and signal retention criteria.
SN  - 2308-3425
ER  -