Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages.
6 affiliations
- 1Department of Anesthesiology, Massachusetts General Hospital, Boston, MA 02114, USA.
- 2Harvard Medical School, Boston, MA 02115, USA.
- 3Department of Computer Science, Donald Bren School of Information and Computer Sciences, University of California, Irvine, Irvine, CA 92697, USA.
- 4Sue and Bill Gross School of Nursing, University of California, Irvine, Irvine, CA 92697, USA.
- 5Department of Medicine, Massachusetts General Hospital, Boston, MA 02114, USA.
- 6Broad Institute, Cambridge, MA 02142, USA.
Abstract
Wearable pulse metrics are typically reported as a single daily, waking, or nightly average. This presentation of the data may mask differences between sleep and wakefulness, temporal variations within a given state, and differences in the amount of signal retained. To determine whether single-value averages provide a representative summary of free-living pulse physiology, we analyzed 28 days of smartwatch and smart-ring data from 35 participants. Sleep and waking periods were identified using the smart-ring sleep data. Pulse rate was obtained from the smartwatch-generated values, and pulse rate variability (PRV) was calculated from the raw photoplethysmography as the root mean square of successive pulse-interval differences (RMSSD) and standard deviation of pulse-to-pulse intervals (SDNN). Analyses compared paired sleep-wake periods and examined temporal variability within both waking and sleep periods. Mean pulse rate was 72.4 beats/min during sleep and 89.1 beats/min during the subsequent waking period (difference: -16.7 beats/min; 95% confidence interval [CI], -23.0 to -10.2). The mean absolute deviation of the five-minute waking pulse-rate measurements from the waking-period mean was 10.89 beats/min (95% CI, 9.75-12.02); on average, 44.6% of waking measurements differed from the mean by more than 10 beats/min. During sleep, the mean absolute deviation from the period mean was 4.30 beats/min (95% CI, 3.17-5.56). From earlier to later sleep, RMSSD increased by 40.8% (95% CI, 18.7-67.5%; q = 0.0001) and SDNN increased by 82.6% (95% CI, 51.4-117.4%; q = 0.0001). Only 8.6% of the waking recordings met the PRV quality criteria, whereas 64.0% of the sleep recordings did. In summary, single-value averages may not capture differences between sleep and wakefulness or temporal structure within states; unequal signal retention may also affect the representativeness of state averages. Therefore, reports of wearable pulse biomarkers should specify sleep-wake state, within-state timing, aggregation method, and signal retention criteria.
Related
- Nightly Sleep and Next-Day Physical Activity Structure and Volume: Within-Individual Associations in 81 537 Adults.
- Wearable-measured 24-hour heart rate variability and neovascular age-related macular degeneration: a cross-sectional study
- Wearable Heart Rate Variability Monitoring, Autonomic Dysfunction and Post-exertional Malaise in Long COVID: An Observational Study
- Feasibility of Wearable Heart Rate Variability Monitoring During a Military Closed-Circuit Rebreather Dive: An Exploratory Case Report.
- Association between the freezing of gait questionnaire score and wearable sensor-derived stride-length variability in Parkinson’s disease
BibTeX
@article{cai2026temporal,
title = {{Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages.}},
author = {Ruixue Cai and Amir Rahmani and Shahab Haghayegh},
journal = {Journal of cardiovascular development and disease},
year = {2026},
month = nov,
doi = {10.3390/jcdd13110589},
url = {https://europepmc.org/article/MED/43083096},
note = {CC BY},
}
RIS
TY - JOUR
TI - Temporal Structure in Free-Living Wearable Pulse Rate and Pulse Rate Variability: Beyond Daily and Nightly Averages.
AU - Ruixue Cai
AU - Amir Rahmani
AU - Shahab Haghayegh
PY - 2026
DA - 2026/11/13
JO - Journal of cardiovascular development and disease
DO - 10.3390/jcdd13110589
UR - https://europepmc.org/article/MED/43083096
AB - Wearable pulse metrics are typically reported as a single daily, waking, or nightly average. This presentation of the data may mask differences between sleep and wakefulness, temporal variations within a given state, and differences in the amount of signal retained. To determine whether single-value averages provide a representative summary of free-living pulse physiology, we analyzed 28 days of smartwatch and smart-ring data from 35 participants. Sleep and waking periods were identified using the smart-ring sleep data. Pulse rate was obtained from the smartwatch-generated values, and pulse rate variability (PRV) was calculated from the raw photoplethysmography as the root mean square of successive pulse-interval differences (RMSSD) and standard deviation of pulse-to-pulse intervals (SDNN). Analyses compared paired sleep-wake periods and examined temporal variability within both waking and sleep periods. Mean pulse rate was 72.4 beats/min during sleep and 89.1 beats/min during the subsequent waking period (difference: -16.7 beats/min; 95% confidence interval [CI], -23.0 to -10.2). The mean absolute deviation of the five-minute waking pulse-rate measurements from the waking-period mean was 10.89 beats/min (95% CI, 9.75-12.02); on average, 44.6% of waking measurements differed from the mean by more than 10 beats/min. During sleep, the mean absolute deviation from the period mean was 4.30 beats/min (95% CI, 3.17-5.56). From earlier to later sleep, RMSSD increased by 40.8% (95% CI, 18.7-67.5%; q = 0.0001) and SDNN increased by 82.6% (95% CI, 51.4-117.4%; q = 0.0001). Only 8.6% of the waking recordings met the PRV quality criteria, whereas 64.0% of the sleep recordings did. In summary, single-value averages may not capture differences between sleep and wakefulness or temporal structure within states; unequal signal retention may also affect the representativeness of state averages. Therefore, reports of wearable pulse biomarkers should specify sleep-wake state, within-state timing, aggregation method, and signal retention criteria.
SN - 2308-3425
ER -