Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 29 min ago
Peer-reviewedCC BY-NCActa radiologica open

Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.

3 more authors
9 affiliations
  1. 1Department of Radiology, Massachusetts General Hospital, Mass General Brigham, Boston, MA, USA.
  2. 2Harvard Medical School, Boston, MA, USA.
  3. 3GE HealthCare, Boston, MA, USA.
  4. 4GE HealthCare, Waukesha, WI, USA.
  5. 5GE HealthCare, Rochester, MN, USA.
  6. 6Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, USA.
  7. 7Department of Radiology, Brigham and Women's Hospital, Mass General Brigham, Boston, MA, USA.
  8. 8Enterprise Service Group - Radiology, Mass General Brigham, Boston, MA, USA.
  9. 9Department of Radiology, University of Turku, Turku, Finland.

Abstract

Background

Motion artifacts can degrade prostate MRI quality. PROPELLER read-out (PR), a radial acquisition technique, is an established approach that can reduce motion artifacts but requires longer acquisition times. We explored whether combining PR with accelerated acquisition and reconstruction methods yields image quality gains while reducing scan times.Purpose

To compare the image quality of standard Cartesian (CR) and PROPELLER read-outs (PR) using an accelerated fast spin echo-based technique (VORTEX), combined with deep learning reconstruction (DLR).Materials and methods

In 80 consecutive patients, VORTEX with CR was performed for the axial, sagittal, and coronal planes with scan time of 84, 50, and 54 s, respectively, while VORTEX with PR was performed in the coronal (71 s) and sagittal planes (92 s), for a total of five imaging datasets. All datasets were reconstructed using a commercially available DLR (AIRTM Recon DL). Five radiologists performed image quality assessments. Inter-reader agreement was estimated using Gwet's AC2 statistics.Results

All VORTEX derived images were assigned a T₂w image PI-QUAL score of ≥3, and all radiologists perceived fewer artifacts in the sagittal and coronal PROPELLER images (p < .001). Four out of five radiologists also observed both superior overall image quality and reduced noise for all PROPELLER derived images (p < .001). Inter-rater agreement was good to very good for all assessments (AC2 0.77-0.88).Conclusion

VORTEX with PR and DLR can achieve fast high-quality T₂w sagittal and coronal imaging of prostate, with all acquisitions completed within 95 s per imaging plane and a total triplanar acquisition time of 4 min 7 s.

Related

  1. Evaluation of a Deep Learning Reconstruction Technique for Accelerated Brain MRI Scans.
    Jonathan Isaac Mandel, Shivaprakash B Hiremath, Hedyeh Keshtgar +2
    Tomography (Ann Arbor, Mich.)Peer-reviewedCC BYFull text1 citedMedical imaging & radiologyEurope PMC
  2. Deep learning reconstruction-applied PROPELLER diffusion-weighted imaging in uterine malignancies: a comparison study with MUSE
    Takuro Gonda, Ryoya Ochiai, Hiroto Yunaga +3
    Japanese Journal of RadiologyPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyPMC
  3. The Boston All‐in‐One Medial Patellofemoral Complex Reconstruction: A Combined Medial Patellofemoral Ligament and Medial Quadriceps Tendon Femoral Ligament Dynamic Tensioning Technique Using Allograft
    Khalid Al-Hourani, Xinning Li
    Arthroscopy techniquesPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  4. Learning optimized sampling patterns for accelerated MRI reconstruction via diffusion models
    Sriram Ravula, Brett Levac, Yamin Arefeen +2
    Journal of Medical ImagingPeer-reviewedLicence not statedFull text22 citedMedical imaging & radiologyPMCOpenAlex
  5. Multiple-Pedicle Peroneal Artery Perforator Propeller Flap for Distal Lower Extremity Reconstruction: Technical Considerations and Preliminary Clinical Outcomes
    Jin-Hyung Im, Joo-Yup Lee, Il-Jung Park +2
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{cochran2026image,
  title = {{Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.}},
  author = {Rory L Cochran and Ranjodh S Dhami and William R Bradley and Robert G Rasmussen and Madhangi Parameswaran and Eugene Milshteyn and Ajeetkumar Gaddipati and Mary Thomas and Anand Venkatachari and Arnaud Guidon and Azadeh Tabari and Susie Y Huang and Clare M Tempany and Mukesh G Harisinghani and Ivan Jambor},
  journal = {Acta radiologica open},
  year = {2026},
  month = oct,
  doi = {10.1177/20584601261492967},
  url = {https://europepmc.org/article/MED/43048090},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.
AU  - Rory L Cochran
AU  - Ranjodh S Dhami
AU  - William R Bradley
AU  - Robert G Rasmussen
AU  - Madhangi Parameswaran
AU  - Eugene Milshteyn
AU  - Ajeetkumar Gaddipati
AU  - Mary Thomas
AU  - Anand Venkatachari
AU  - Arnaud Guidon
AU  - Azadeh Tabari
AU  - Susie Y Huang
AU  - Clare M Tempany
AU  - Mukesh G Harisinghani
AU  - Ivan Jambor
PY  - 2026
DA  - 2026/10/10
JO  - Acta radiologica open
DO  - 10.1177/20584601261492967
UR  - https://europepmc.org/article/MED/43048090
AB  - Background  Motion artifacts can degrade prostate MRI quality. PROPELLER read-out (PR), a radial acquisition technique, is an established approach that can reduce motion artifacts but requires longer acquisition times. We explored whether combining PR with accelerated acquisition and reconstruction methods yields image quality gains while reducing scan times.Purpose  To compare the image quality of standard Cartesian (CR) and PROPELLER read-outs (PR) using an accelerated fast spin echo-based technique (VORTEX), combined with deep learning reconstruction (DLR).Materials and methods  In 80 consecutive patients, VORTEX with CR was performed for the axial, sagittal, and coronal planes with scan time of 84, 50, and 54 s, respectively, while VORTEX with PR was performed in the coronal (71 s) and sagittal planes (92 s), for a total of five imaging datasets. All datasets were reconstructed using a commercially available DLR (AIRTM Recon DL). Five radiologists performed image quality assessments. Inter-reader agreement was estimated using Gwet's AC2 statistics.Results  All VORTEX derived images were assigned a T₂w image PI-QUAL score of ≥3, and all radiologists perceived fewer artifacts in the sagittal and coronal PROPELLER images (p < .001). Four out of five radiologists also observed both superior overall image quality and reduced noise for all PROPELLER derived images (p < .001). Inter-rater agreement was good to very good for all assessments (AC2 0.77-0.88).Conclusion  VORTEX with PR and DLR can achieve fast high-quality T₂w sagittal and coronal imaging of prostate, with all acquisitions completed within 95 s per imaging plane and a total triplanar acquisition time of 4 min 7 s.
SN  - 2058-4601
ER  -