Evaluation of a Deep Learning Reconstruction Technique for Accelerated Brain MRI Scans.
- 1Department of Medical Imaging, University of Toronto, Toronto, ON M5T 1W7, Canada.
- 2Foqus Technologies Inc., Kitchener, ON N2G 1L5, Canada.
- 3Department of Medical Biophysics, Western University, London, ON N6A 5C1, Canada.
Abstract
Background/objectives
Magnetic resonance imaging (MRI) is a cornerstone of diagnostic imaging, providing exceptional soft tissue contrast and enabling detailed characterization of neurological, vascular, and musculoskeletal diseases. Despite its clinical utility, prolonged acquisition times remain a primary limitation of MRI. Extended scan durations increase patient discomfort, particularly in vulnerable populations, which elevate the risk of motion artifacts that can degrade image quality and necessitate repeat imaging. Recent advances in machine learning, especially deep learning (DL), promise to ameliorate these limitations by enabling high-quality MRI reconstruction from heavily undersampled data, increasing throughput capacity and improving healthcare delivery efficiency. This work describes an FDA-cleared DL algorithm known as DeepFoqus-Accelerate for the reconstruction of deliberately under-sampled magnetic resonance imaging data.Methods
Fully sampled k-space from 408 brain MRI volumes (108 from 18 healthy volunteers and 300 from the public fastMRI dataset) was retrospectively undersampled. A detailed comparison of reconstructed images using DeepFoqus-Accelerate with corresponding fully sampled clinical images is presented using expert evaluation of overall image quality and quantitative similarity metrics. The only conventional comparator included in the study was GE's parallel imaging reconstruction (ARC) at matched retrospective undersampling; comparisons with compressed sensing and vendor-specific deep-learning reconstruction methods were outside the study design.Results
This algorithm can allow for a four-fold reduction in brain imaging times relative to a fully sampled acquisition while preserving image quality. No reader rated any reconstruction below the acceptability threshold, and DeepFoqus-Accelerate exceeded ARC on all metrics at 4×.Conclusions
The findings characterize image quality and structural fidelity relative to fully sampled references and support further evaluation of diagnostic performance, with the potential to improve imaging efficiency and patient experience.
Related
- Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.
- Evaluation of accelerated whole-body diffusion weighted imaging with deep learning reconstruction in patients with metastatic prostate cancer: assessment of image quality and ADC estimates.
- Automated Brain Segmentation in Accelerated T2-Weighted MRI: Effects of Deep Learning-Based Reconstruction
- Learning optimized sampling patterns for accelerated MRI reconstruction via diffusion models
- An Inline‐Integrable Image Restoration Model With ROI Fine‐Tuning and Slice‐to‐Volume Reconstruction for Accelerated Whole‐Brain Vessel Wall Imaging
BibTeX
@article{mandel2026evaluation,
title = {{Evaluation of a Deep Learning Reconstruction Technique for Accelerated Brain MRI Scans.}},
author = {Jonathan Isaac Mandel and Shivaprakash B Hiremath and Hedyeh Keshtgar and Timothy James Scholl and Sadegh Raeisi},
journal = {Tomography (Ann Arbor, Mich.)},
year = {2026},
month = nov,
doi = {10.3390/tomography12110159},
url = {https://europepmc.org/article/MED/43083649},
note = {CC BY},
}
RIS
TY - JOUR
TI - Evaluation of a Deep Learning Reconstruction Technique for Accelerated Brain MRI Scans.
AU - Jonathan Isaac Mandel
AU - Shivaprakash B Hiremath
AU - Hedyeh Keshtgar
AU - Timothy James Scholl
AU - Sadegh Raeisi
PY - 2026
DA - 2026/11/06
JO - Tomography (Ann Arbor, Mich.)
DO - 10.3390/tomography12110159
UR - https://europepmc.org/article/MED/43083649
AB - Background/objectives Magnetic resonance imaging (MRI) is a cornerstone of diagnostic imaging, providing exceptional soft tissue contrast and enabling detailed characterization of neurological, vascular, and musculoskeletal diseases. Despite its clinical utility, prolonged acquisition times remain a primary limitation of MRI. Extended scan durations increase patient discomfort, particularly in vulnerable populations, which elevate the risk of motion artifacts that can degrade image quality and necessitate repeat imaging. Recent advances in machine learning, especially deep learning (DL), promise to ameliorate these limitations by enabling high-quality MRI reconstruction from heavily undersampled data, increasing throughput capacity and improving healthcare delivery efficiency. This work describes an FDA-cleared DL algorithm known as DeepFoqus-Accelerate for the reconstruction of deliberately under-sampled magnetic resonance imaging data.Methods Fully sampled k-space from 408 brain MRI volumes (108 from 18 healthy volunteers and 300 from the public fastMRI dataset) was retrospectively undersampled. A detailed comparison of reconstructed images using DeepFoqus-Accelerate with corresponding fully sampled clinical images is presented using expert evaluation of overall image quality and quantitative similarity metrics. The only conventional comparator included in the study was GE's parallel imaging reconstruction (ARC) at matched retrospective undersampling; comparisons with compressed sensing and vendor-specific deep-learning reconstruction methods were outside the study design.Results This algorithm can allow for a four-fold reduction in brain imaging times relative to a fully sampled acquisition while preserving image quality. No reader rated any reconstruction below the acceptability threshold, and DeepFoqus-Accelerate exceeded ARC on all metrics at 4×.Conclusions The findings characterize image quality and structural fidelity relative to fully sampled references and support further evaluation of diagnostic performance, with the potential to improve imaging efficiency and patient experience.
SN - 2379-1381
SN - 2379-139X
ER -