Skip to content
DraconiticResearch
Search Sources API
182,469 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BYJournal of medical microbiology

Correlation between phenotypic disc diffusion test and PCR molecular test for detection of methicillin resistance in Staphylococcus epidermidis and Staphylococcus hominis.

  1. 1Departamento de Salud Pública, Facultad de Medicina, Universidad Nacional Autónoma de México, Ciudad de México, Mexico.

Abstract

Introduction. Coagulase-negative staphylococci (CoNS), particularly Staphylococcus epidermidis, are leading opportunistic pathogens in neonatal intensive care units, frequently associated with late-onset sepsis and medical device colonization.Gap statement. Cefoxitin disk diffusion has been adopted internationally as a surrogate marker for mecA, but its accuracy in CoNS is heterogeneous; high resistance rates and erratic phenotypic expression in species like Staphylococcus hominis indicate that the existing phenotypic-only approach does not transfer reliably between species and cohorts.Aim. Evaluate the diagnostic accuracy of oxacillin agar dilution (AD) and cefoxitin disc diffusion against mecA PCR in 664 coagulase-negative staphylococcal isolates collected over an 8-year period (2006-2014) at a tertiary-level hospital.Methodology. Phenotypic detection of methicillin resistance was performed by oxacillin AD with 4% NaCl/24 h and by cefoxitin disk diffusion (≤24 mm), using mecA PCR as the reference standard; inducible clindamycin resistance (iMLS_B) was screened by D-test. All isolates were stratified by species (S. epidermidis, S. hominis) and cohort (neonatal versus adult), with concordance quantified using Cohen's κ coefficient under the Landis and Koch framework.Results. S. epidermidis accounted for 87.2% and S. hominis for 8.6% of isolates, with 83.1% originating from neonates. In neonatal S. epidermidis, mecA prevalence reached 80%. Oxacillin AD demonstrated superior performance with 87.1% sensitivity (neonates) and 78.3% (adults), with moderate agreement in both subgroups (κ=0.44-0.54, respectively). The D-test further revealed a 20.8% prevalence of the inducible clindamycin resistance phenotype (iMLS_B) in neonatal S. hominis, indicating a high risk of therapeutic failure despite an apparently susceptible routine antibiogram, a prevalence nearly 20-fold higher than that observed in neonatal S. epidermidis (1.0%, n=5), identifying S. hominis as a particularly problematic inducible-clindamycin-resistance reservoir in the NICU setting.Conclusion. High resistance rates and erratic phenotypic expression in species like S. hominis, together with the unequal accuracy of phenotypic methods between neonates and adults, require a species-specific diagnostic approach. While oxacillin AD remains a robust predictor for both species and cohorts in this setting, systematic D-test implementation and mecA molecular confirmation are essential to ensure effective antimicrobial therapy.

Related

  1. A Duplex Isothermal RPA–Lateral Flow Platform for Concurrent Detection of Staphylococcus Aureus and mecA-Mediated Methicillin Resistance
    Jutturong Ckumdee, Somchai Santiwatanakul, Kwanchai Onruang +1
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMCDOAJ
  2. Impact of methicillin resistance on mortality in Staphylococcus aureus endocarditis: a systematic review and meta-analysis
    Durga Shankar Meena, Deepak Kumar, Gopal Krishana Bohra
    Communications MedicinePeer-reviewedCC BYFull text1 citedEpidemiology & public healthDOAJ
  3. High prevalence and multidrug resistance of Methicillin-resistant Staphylococcus aureus at a provincial referral hospital in Zambia: A 5-year retrospective study
    Mavis S. Nyakayoya, Dennis Chisala, Kennedy Lubundi +4
    PLOS Global Public HealthPeer-reviewedCC BY 4.0Full textMicrobiologyPharmacology & toxicologyPLOS
  4. Methicillin resistance and antimicrobial non-susceptibility trends among Staphylococcus aureus clinical isolates in Aseer, Saudi Arabia (2013–2024): A retrospective laboratory-based surveillance study
    Abdulah J. Alqahtani, Yahya Shabi, Ghaday Hadi +9
    PLOS OnePeer-reviewedCC BY 4.0Full textMicrobiologyPharmacology & toxicologyPLOS
  5. Chlorhexidine MIC distribution, efflux pump gene profiles, and genotypic characteristics among clinical methicillin-resistant and methicillin-susceptible Staphylococcus aureus isolates
    Mina Golban, Javad Charostad, Hossein Kazemian +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textInfectious diseaseCrossref
BibTeX
@article{gonzalezlopez2026correlation,
  title = {{Correlation between phenotypic disc diffusion test and PCR molecular test for detection of methicillin resistance in Staphylococcus epidermidis and Staphylococcus hominis.}},
  author = {Lorena Gonzalez-Lopez and Ruben Morelos-Ramirez and Roberto Cabrera},
  journal = {Journal of medical microbiology},
  year = {2026},
  month = nov,
  doi = {10.1099/jmm.0.002207},
  url = {https://europepmc.org/article/MED/42975560},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Correlation between phenotypic disc diffusion test and PCR molecular test for detection of methicillin resistance in Staphylococcus epidermidis and Staphylococcus hominis.
AU  - Lorena Gonzalez-Lopez
AU  - Ruben Morelos-Ramirez
AU  - Roberto Cabrera
PY  - 2026
DA  - 2026/11/01
JO  - Journal of medical microbiology
DO  - 10.1099/jmm.0.002207
UR  - https://europepmc.org/article/MED/42975560
AB  - Introduction. Coagulase-negative staphylococci (CoNS), particularly Staphylococcus epidermidis, are leading opportunistic pathogens in neonatal intensive care units, frequently associated with late-onset sepsis and medical device colonization.Gap statement. Cefoxitin disk diffusion has been adopted internationally as a surrogate marker for mecA, but its accuracy in CoNS is heterogeneous; high resistance rates and erratic phenotypic expression in species like Staphylococcus hominis indicate that the existing phenotypic-only approach does not transfer reliably between species and cohorts.Aim. Evaluate the diagnostic accuracy of oxacillin agar dilution (AD) and cefoxitin disc diffusion against mecA PCR in 664 coagulase-negative staphylococcal isolates collected over an 8-year period (2006-2014) at a tertiary-level hospital.Methodology. Phenotypic detection of methicillin resistance was performed by oxacillin AD with 4% NaCl/24 h and by cefoxitin disk diffusion (≤24 mm), using mecA PCR as the reference standard; inducible clindamycin resistance (iMLS_B) was screened by D-test. All isolates were stratified by species (S. epidermidis, S. hominis) and cohort (neonatal versus adult), with concordance quantified using Cohen's κ coefficient under the Landis and Koch framework.Results. S. epidermidis accounted for 87.2% and S. hominis for 8.6% of isolates, with 83.1% originating from neonates. In neonatal S. epidermidis, mecA prevalence reached 80%. Oxacillin AD demonstrated superior performance with 87.1% sensitivity (neonates) and 78.3% (adults), with moderate agreement in both subgroups (κ=0.44-0.54, respectively). The D-test further revealed a 20.8% prevalence of the inducible clindamycin resistance phenotype (iMLS_B) in neonatal S. hominis, indicating a high risk of therapeutic failure despite an apparently susceptible routine antibiogram, a prevalence nearly 20-fold higher than that observed in neonatal S. epidermidis (1.0%, n=5), identifying S. hominis as a particularly problematic inducible-clindamycin-resistance reservoir in the NICU setting.Conclusion. High resistance rates and erratic phenotypic expression in species like S. hominis, together with the unequal accuracy of phenotypic methods between neonates and adults, require a species-specific diagnostic approach. While oxacillin AD remains a robust predictor for both species and cohorts in this setting, systematic D-test implementation and mecA molecular confirmation are essential to ensure effective antimicrobial therapy.
SN  - 0022-2615
SN  - 1473-5644
ER  -