Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 7 min ago
Peer-reviewedCC BY 4.0Frontiers in Bioengineering and Biotechnology

Development and technical characterization of a biomimetic thorax simulator for regional intrapulmonary pressure measurement

7 affiliations
  1. 1Faculty of Health Sciences, University of Applied Sciences, Giessen, Germany
  2. 2Medical Faculty, Justus Liebig University, Giessen, Germany
  3. 3Institute of Medical Informatics (IMI), Justus-Liebig-University, Giessen, Germany
  4. 4Faculty of Veterinary Medicine, Small Animal Clinic, Justus Liebig University, Giessen, Germany
  5. 5Department of Internal Medicine, Universities of Giessen and Marburg Lung Center, German Center for Lung Research (DZL), Giessen, Germany
  6. 6Institute for Lung Health (ILH), Giessen, Germany
  7. 7Excellence Cluster Cardio-Pulmonary Institute (CPI), Giessen, Germany

Abstract

Background: Mechanical ventilation is a cornerstone therapy for respiratory failure, but heterogeneous regional pressure distribution can lead to localized lung stress and ventilator-induced lung injury. To accurately investigate these dynamics, physiologically realistic experimental platforms are required. However, current experimental models either rely on simplified mechanical lung analogues or lack the capability to measure spatially resolved intrapulmonary pressure dynamics.

Methods: A biomimetic thorax–lung simulator incorporating an ex vivo porcine lung was used to measure regional intrapulmonary pressures during pressure-controlled mechanical ventilation. The lung was positioned within an airtight thoracic chamber operated at a nominal subatmospheric baseline pressure and connected to an anatomically realistic upper airway model. Pressure signals were recorded simultaneously at seven anatomical locations, including the trachea, main bronchi, and upper and lower lung regions. Ventilation was performed across positive end-expiratory pressure (PEEP) levels ranging from 0 to 20 mbar while maintaining a constant driving pressure of 15 mbar. Regional pressure transmission, pressure-trajectory hysteresis, and Poincaré-derived dispersion were analyzed together with tidal volume and dynamic system compliance.

Results: The platform enabled simultaneous acquisition of regional intrapulmonary pressure signals, airway pressure, flow, and chamber pressure across all investigated ventilator settings. Repeated measurements showed high within-specimen technical repeatability, with repeated median regional pressure values differing by approximately 0.02 mbar. Regional pressure attenuation, pressure-flow indices, and trachea-to-region regression parameters were derived as engineering metrics of pressure transmission. Tidal volume and dynamic system compliance were reconstructed from the synchronized flow and tracheal-pressure signals. In the investigated specimen, peripheral regions showed greater pressure-trajectory hysteresis and pressure-state dispersion at low PEEP than under higher PEEP conditions.

Conclusion: The developed platform enables synchronized regional intrapulmonary pressure measurements under controlled mechanical ventilation and showed high short-term within-specimen repeatability. In the investigated specimen, static pressure transmission was largely homogeneous, whereas regional pressure-trajectory dynamics differed between central and peripheral measurement sites, particularly at low PEEP. Increasing PEEP was associated with reduced regional pressure-trajectory hysteresis and variability within this specimen. These findings demonstrate the technical feasibility of the platform and provide a basis for subsequent validation in additional specimens and against independent physiological reference data.

Related

  1. Technical validation and feasibility of video particle tracking for low-volume measurement of biliary micro-viscosity after liver transplantation
    Ludwig Lenz, Philip Friedrich, Peggy Stock +9
    Scientific ReportsPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossref
  2. Metoidioplasty in a case of 46 XY disorder of sexual development: Technical considerations for masculinizing genitoplasty.
    Boris Kangabam, R Bharath, Thiyam Lokendro +1
    Indian journal of urology : IJU : journal of the Urological Society of IndiaPeer-reviewedCC BY-NC-SAFull textGeneral medicineEurope PMC
  3. Development of mechanically optimized biomimetic hybrid scaffold–stem cell constructs for functional tendon regeneration and restoration of mechanical integrity
    Alani Mohanad Khalid Ahmed
    PLOS OnePeer-reviewedCC BY 4.0Full textDevelopmental biologyPhysiologyPLOS
  4. Characterization and technical evaluation of physicochemical properties of Tibetan medicine Zuotai via modern processing
    Renzhen Wangjia, Gaden Nyima, Kelsang Gyab Ala +2
    Frontiers in PharmacologyPeer-reviewedCC BY 4.0Full textPharmacology & toxicologyCrossrefEurope PMCPMC
  5. Luspatercept in myelodysplastic syndrome with ring sideroblasts: a case report of intrapulmonary vascular dilatation syndrome causing protracted inexplicable hypoxia
    Ayesha Warsi, Marie E. Faughnan, Rena Buckstein
    HaematologicaPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
BibTeX
@article{sohrabi2026development,
  title = {{Development and technical characterization of a biomimetic thorax simulator for regional intrapulmonary pressure measurement}},
  author = {Keywan Sohrabi and Jasmin Spaar and Tibor Jung and Niklas Ostwald and Patrick Fischer and Oskar Seifert and Dominik Kraft and István Vadász},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2026},
  month = oct,
  doi = {10.3389/fbioe.2026.1907500},
  url = {https://doi.org/10.3389/fbioe.2026.1907500},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Development and technical characterization of a biomimetic thorax simulator for regional intrapulmonary pressure measurement
AU  - Keywan Sohrabi
AU  - Jasmin Spaar
AU  - Tibor Jung
AU  - Niklas Ostwald
AU  - Patrick Fischer
AU  - Oskar Seifert
AU  - Dominik Kraft
AU  - István Vadász
PY  - 2026
DA  - 2026/10/22
JO  - Frontiers in Bioengineering and Biotechnology
DO  - 10.3389/fbioe.2026.1907500
UR  - https://doi.org/10.3389/fbioe.2026.1907500
AB  - Background: Mechanical ventilation is a cornerstone therapy for respiratory failure, but heterogeneous regional pressure distribution can lead to localized lung stress and ventilator-induced lung injury. To accurately investigate these dynamics, physiologically realistic experimental platforms are required. However, current experimental models either rely on simplified mechanical lung analogues or lack the capability to measure spatially resolved intrapulmonary pressure dynamics.  Methods: A biomimetic thorax–lung simulator incorporating an ex vivo porcine lung was used to measure regional intrapulmonary pressures during pressure-controlled mechanical ventilation. The lung was positioned within an airtight thoracic chamber operated at a nominal subatmospheric baseline pressure and connected to an anatomically realistic upper airway model. Pressure signals were recorded simultaneously at seven anatomical locations, including the trachea, main bronchi, and upper and lower lung regions. Ventilation was performed across positive end-expiratory pressure (PEEP) levels ranging from 0 to 20 mbar while maintaining a constant driving pressure of 15 mbar. Regional pressure transmission, pressure-trajectory hysteresis, and Poincaré-derived dispersion were analyzed together with tidal volume and dynamic system compliance.  Results: The platform enabled simultaneous acquisition of regional intrapulmonary pressure signals, airway pressure, flow, and chamber pressure across all investigated ventilator settings. Repeated measurements showed high within-specimen technical repeatability, with repeated median regional pressure values differing by approximately 0.02 mbar. Regional pressure attenuation, pressure-flow indices, and trachea-to-region regression parameters were derived as engineering metrics of pressure transmission. Tidal volume and dynamic system compliance were reconstructed from the synchronized flow and tracheal-pressure signals. In the investigated specimen, peripheral regions showed greater pressure-trajectory hysteresis and pressure-state dispersion at low PEEP than under higher PEEP conditions.  Conclusion: The developed platform enables synchronized regional intrapulmonary pressure measurements under controlled mechanical ventilation and showed high short-term within-specimen repeatability. In the investigated specimen, static pressure transmission was largely homogeneous, whereas regional pressure-trajectory dynamics differed between central and peripheral measurement sites, particularly at low PEEP. Increasing PEEP was associated with reduced regional pressure-trajectory hysteresis and variability within this specimen. These findings demonstrate the technical feasibility of the platform and provide a basis for subsequent validation in additional specimens and against independent physiological reference data.
SN  - 2296-4185
ER  -