What are the experiences, perceptions and training needs of inpatient general nursing staff on Continuous Glucose Monitoring?
- 1University of East Anglia
Abstract
BackgroundAlthough point-of-care testing is the standard method for inpatient glucose monitoring; it is associated with patient discomfort and late detection of dysglycaemic events. Continuous glucose monitoring (CGM) may improve glycaemic management; however, limited staff education and experience among may hinder its implementation.
AimTo investigate experience, perceptions and training needs on CGM use among inpatient nursing staff across diverse hospital wards.
MethodsThis is a single-centre, 38-item online survey recruited inpatient nurses in a hospital in the UK. Participants were invited via the e-newsletter and posters; the survey remained open for five months.
ResultsNineteen nurses reported positive perceptions of inpatient CGM. Most considered CGM reliable (77.8%) and preferred CGM combined with POCT (66.7%). Views on its impact on workload and patient-room entries were mixed (30% agreed, 30% disagreed). Training needs included sensor placement (92.9%) and alarm management (78.6%).
ConclusionNurses viewed CGM favourably but highlighted important training needs for inpatient use.
Key points1. Inpatient nurses generally viewed CGM positively and considered it as a reliable tool. 2. Most nurses preferred using CGM alongside POCT, while views on its impact on patient-room entries were mixed. 3. Most nurses identified further training needs, particularly for sensor placement and CGM alarm management. 4. The small, single-site voluntary sample limits generalisability; findings should be confirmed in larger, multicentre studies.
Related
- Pediatric Inpatient Continuous Glucose Monitoring: Development and Implementation of a Hospital Policy for Accuracy-Validated Insulin Dosing
- An international position statement on practical approaches for inpatient continuous glucose monitoring, insulin pumps and automated insulin delivery systems in adults
- Alogliptin-Pioglitazone and Insulin Regimen for Inpatient Glycemic Control: A Randomized Continuous Glucose Monitoring Pilot Trial
- Inpatient continuous glucose monitoring halves the risk of hypoglycemia in patients with hyperinsulinism
- Continuous glucose monitoring reveals thyroid feedback-related residual glycemic variability and hypoglycemia during inpatient glucose optimization in euthyroid adults with type 2 diabetes: a CGM-based observational study.
BibTeX
@misc{ergin2026what,
title = {{What are the experiences, perceptions and training needs of inpatient general nursing staff on Continuous Glucose Monitoring?}},
author = {B. Donat Ergin and K. Mattishent and D. Holder and A. M. Minihane and B. Kelly and R. Holt and H. Murphy and K. Dhatariya and M. Hornberger},
howpublished = {medRxiv},
year = {2026},
month = oct,
doi = {10.64898/2026.10.14.26365417},
url = {https://www.medrxiv.org/content/10.64898/2026.10.14.26365417v1},
note = {CC BY-NC},
}
RIS
TY - UNPB
TI - What are the experiences, perceptions and training needs of inpatient general nursing staff on Continuous Glucose Monitoring?
AU - B. Donat Ergin
AU - K. Mattishent
AU - D. Holder
AU - A. M. Minihane
AU - B. Kelly
AU - R. Holt
AU - H. Murphy
AU - K. Dhatariya
AU - M. Hornberger
PY - 2026
DA - 2026/10/14
PB - medRxiv
DO - 10.64898/2026.10.14.26365417
UR - https://www.medrxiv.org/content/10.64898/2026.10.14.26365417v1
AB - BackgroundAlthough point-of-care testing is the standard method for inpatient glucose monitoring; it is associated with patient discomfort and late detection of dysglycaemic events. Continuous glucose monitoring (CGM) may improve glycaemic management; however, limited staff education and experience among may hinder its implementation. AimTo investigate experience, perceptions and training needs on CGM use among inpatient nursing staff across diverse hospital wards. MethodsThis is a single-centre, 38-item online survey recruited inpatient nurses in a hospital in the UK. Participants were invited via the e-newsletter and posters; the survey remained open for five months. ResultsNineteen nurses reported positive perceptions of inpatient CGM. Most considered CGM reliable (77.8%) and preferred CGM combined with POCT (66.7%). Views on its impact on workload and patient-room entries were mixed (30% agreed, 30% disagreed). Training needs included sensor placement (92.9%) and alarm management (78.6%). ConclusionNurses viewed CGM favourably but highlighted important training needs for inpatient use. Key points1. Inpatient nurses generally viewed CGM positively and considered it as a reliable tool. 2. Most nurses preferred using CGM alongside POCT, while views on its impact on patient-room entries were mixed. 3. Most nurses identified further training needs, particularly for sensor placement and CGM alarm management. 4. The small, single-site voluntary sample limits generalisability; findings should be confirmed in larger, multicentre studies.
ER -