Skip to content
DraconiticResearch
Search Sources API
186,086 studies31 sourcesUpdated 52 min ago
Peer-reviewedCC BY-NC-NDActa neurochirurgica

Clinical utility of SPECT/CT radionuclide shuntgraphy in suspected ventriculoperitoneal shunt dysfunction.

7 affiliations
  1. 1Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan, 430071, China.
  2. 2Brain Research Center, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China.
  3. 3Department of Nuclear Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Donghu Road 169, Wuhan, 430071, China.
  4. 4Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan, 430071, China. [email protected].
  5. 5Brain Research Center, Zhongnan Hospital of Wuhan University, Wuhan, 430071, China. [email protected].
  6. 6Department of Nuclear Medicine, Zhongnan Hospital of Wuhan University, Wuhan University, Donghu Road 169, Wuhan, 430071, China. [email protected].
  7. 7Department of Neurosurgery, Zhongnan Hospital of Wuhan University, Donghu Road 169, Wuhan, 430071, China. [email protected].

Abstract

Objective

This study aims to develop and validate a more efficient diagnostic system for suspected ventriculoperitoneal shunt dysfunction by integrating traditional radionuclide shuntgraphy with SPECT imaging.Methods

This retrospective study examined patients with suspected shunt malfunction admitted to our neurosurgery department from 2021 to 2024, who underwent SPECT/CT imaging of the ventricular shunt. SPECT/CT results were categorized as three groups based on tracer behavior: normal shunt function, partial obstruction, and shunt obstruction. Baseline data, imaging characteristics and clinical management were recorded. Diagnostic agreement with surgery was analyzed only in patients who underwent revision, the only subgroup with a definitive intraoperative reference standard.Result

A study of 46 SPECT/CT images from 42 patients found 14 normal shunt functions, 23 with partial obstruction, and 9 with complete obstruction. Nineteen patients underwent surgery, and SPECT/CT demonstrated good agreement with intraoperative findings (16/19), corresponding to a sensitivity of 88.9%. Specificity could not be reliably estimated because there were no true-negative surgical cases. Thin-slice CT scans assessing shunt catheter position and morphology revealed abnormalities such as malposition of the ventricular or abdominal catheter, tortuosity in the abdominal segment, and obstruction or rupture of the catheter body. Abnormal shunt tube positioning or morphology was more prevalent in the obstruction group (p = 0.0083).Conclusion

In this heterogeneous clinical population, the SPECT/CT shunt imaging diagnostic system prove0d feasible and clinically informative.

Related

  1. Stereotactic guidance for ventricular catheter placement in ventriculoperitoneal shunt surgery: a state-of-the-art review on technical rationale, clinical outcomes, and future directions.
    Erich Talamoni Fonoff, Igor Baroni Cardoso, Alexandre Maria Santos
    Frontiers in neurologyPeer-reviewedCC BYFull textNeuroscienceEurope PMCCrossref
  2. Feasibility of a Patient-Specific Digital Twin for Ventriculoperitoneal Shunt Trajectory Planning
    Kritsanavis Chongsrid, Vich Yindeedej, Supaporn Konmun +2
    arXivPreprintarXiv licenceFull textBioinformatics & computational biologyarXiv
  3. Motor network neurophysiological (TMS-EEG) markers as predictors of outcomes of ventriculoperitoneal shunt sustained for over a year in normal pressure hydrocephalus.
    Tal Davidy, Alexandra Suminski, Yakov Zauberman +8
    Fluids and barriers of the CNSPeer-reviewedCC BY-NC-NDFull textNeuroscienceEurope PMCDOAJ
  4. Pre-transplant whole blood transcriptomic profiling identifies mRNAs linked to cirrhosis-associated immune dysfunction as candidate predictors of clinical outcomes after liver transplantation: an exploratory study
    Marie-Charlotte Delignette, Estelle Peronnet, Arnaud Riff +14
    Transplant InternationalPeer-reviewedCC BYFull textGeneral biologyEpidemiology & public healthHAL
  5. Low-Density Lipoprotein Cholesterol and Cerebral Pericyte Dysfunction in Acute Ischemic Stroke: Clinical and Experimental Evidence
    F. Wang, W. Quan, G. Wu +10
    bioRxivPreprintCC BY-NC-NDFull textNeurosciencebioRxiv
BibTeX
@article{wei2026clinical,
  title = {{Clinical utility of SPECT/CT radionuclide shuntgraphy in suspected ventriculoperitoneal shunt dysfunction.}},
  author = {Zixuan Wei and Ziwei Pi and Jibo Zhang and Chengshi Xu and Linglong Jiang and Wenyu Li and Tingbao Zhang and Meijuan Shen and Jincao Chen},
  journal = {Acta neurochirurgica},
  year = {2026},
  month = aug,
  doi = {10.1007/s00701-026-06998-x},
  url = {https://europepmc.org/article/MED/42901992},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Clinical utility of SPECT/CT radionuclide shuntgraphy in suspected ventriculoperitoneal shunt dysfunction.
AU  - Zixuan Wei
AU  - Ziwei Pi
AU  - Jibo Zhang
AU  - Chengshi Xu
AU  - Linglong Jiang
AU  - Wenyu Li
AU  - Tingbao Zhang
AU  - Meijuan Shen
AU  - Jincao Chen
PY  - 2026
DA  - 2026/08/01
JO  - Acta neurochirurgica
DO  - 10.1007/s00701-026-06998-x
UR  - https://europepmc.org/article/MED/42901992
AB  - Objective  This study aims to develop and validate a more efficient diagnostic system for suspected ventriculoperitoneal shunt dysfunction by integrating traditional radionuclide shuntgraphy with SPECT imaging.Methods  This retrospective study examined patients with suspected shunt malfunction admitted to our neurosurgery department from 2021 to 2024, who underwent SPECT/CT imaging of the ventricular shunt. SPECT/CT results were categorized as three groups based on tracer behavior: normal shunt function, partial obstruction, and shunt obstruction. Baseline data, imaging characteristics and clinical management were recorded. Diagnostic agreement with surgery was analyzed only in patients who underwent revision, the only subgroup with a definitive intraoperative reference standard.Result  A study of 46 SPECT/CT images from 42 patients found 14 normal shunt functions, 23 with partial obstruction, and 9 with complete obstruction. Nineteen patients underwent surgery, and SPECT/CT demonstrated good agreement with intraoperative findings (16/19), corresponding to a sensitivity of 88.9%. Specificity could not be reliably estimated because there were no true-negative surgical cases. Thin-slice CT scans assessing shunt catheter position and morphology revealed abnormalities such as malposition of the ventricular or abdominal catheter, tortuosity in the abdominal segment, and obstruction or rupture of the catheter body. Abnormal shunt tube positioning or morphology was more prevalent in the obstruction group (p = 0.0083).Conclusion  In this heterogeneous clinical population, the SPECT/CT shunt imaging diagnostic system prove0d feasible and clinically informative.
SN  - 0001-6268
SN  - 0942-0940
ER  -