Influence of Head Position on Fundus-Based Ocular Torsion: Implications for Assessing Otolith-Ocular Function.
4 affiliations
- 1Department of Neuroscience, Johns Hopkins University, Baltimore, MD 21218, USA.
- 2NeuroAgent AI, Baltimore, MD 21231, USA.
- 3Department of Neurology, Johns Hopkins Hospital, Baltimore, MD 21287, USA.
- 4Department of Otolaryngology, Johns Hopkins School of Medicine, Baltimore, MD 21287, USA.
Abstract
Background: Ocular counter-roll (OCR) is an otolith-mediated vestibulo-ocular reflex that produces torsional rotation of the eyes in response to head tilt. Accordingly, measuring ocular torsion can provide an assessment of vestibular tone balance related to otolith function. This can be objectively quantified from fundus photographs using the disc-foveal angle (DFA). Because head tilt also physiologically alters ocular torsion through OCR, head position during fundus imaging may influence the measured DFA. Here, we examined this effect of head tilt and the resulting OCR on fundus-based measurements of ocular torsion. Methods: Ten healthy adults (age 28-45 y/o; 2 females) underwent bilateral fundus photography under three conditions: routine head placement, controlled upright (0°) positioning, and 10° lateral head tilt. Head orientation was continuously measured using a strap-mounted gyroscope. DFA was quantified from fundus images as the angle between the fovea-optic disc axis and horizontal meridian using ImageJ. Results: Mean DFA did not differ between standard and controlled head positioning (p = 0.23), although within-subject variability was greater with standard positioning (p = 0.020). In contrast, 10° head tilt significantly changed DFA (p < 0.01). Conclusions: Small, naturally occurring variations in head position do not significantly alter DFA but may increase measurement variability, whereas larger head tilts produce significant changes in DFA. Careful control of head position during fundus photography can improve the reliability of DFA measurements for assessment of otolith-ocular function.
Related
- Quantitative assessment of the influence of tapered dies and compaction position on the propensity of lamination due to air entrapment during pharmaceutical compression
- Assessing the Influence of Propofol Sedation Versus Propofol-Free Sedation on Recovery From Sepsis and Septic Shock in Mechanically Ventilated ICU Patients: A Retrospective, Propensity-Score Matched, Cohort Study
- Prospective evaluation assessing the influence of outcome definition, cohort inclusion and DORIS remission in predicting adverse pregnancy outcomes in women with systemic lupus erythematosus.
- Minimizing the influence of magnetic vestibular stimulation inside MRI scanners by adjusting head position.
- The effect of socioeconomic position across the life course on cognitive function among older adults in China
BibTeX
@article{lakhia2026influence,
title = {{Influence of Head Position on Fundus-Based Ocular Torsion: Implications for Assessing Otolith-Ocular Function.}},
author = {Arnav Lakhia and Kemar Green and Amir Kheradmand and David Hale},
journal = {Audiology research},
year = {2026},
month = nov,
doi = {10.3390/audiolres16060171},
url = {https://europepmc.org/article/MED/43081436},
note = {CC BY},
}
RIS
TY - JOUR
TI - Influence of Head Position on Fundus-Based Ocular Torsion: Implications for Assessing Otolith-Ocular Function.
AU - Arnav Lakhia
AU - Kemar Green
AU - Amir Kheradmand
AU - David Hale
PY - 2026
DA - 2026/11/05
JO - Audiology research
DO - 10.3390/audiolres16060171
UR - https://europepmc.org/article/MED/43081436
AB - Background: Ocular counter-roll (OCR) is an otolith-mediated vestibulo-ocular reflex that produces torsional rotation of the eyes in response to head tilt. Accordingly, measuring ocular torsion can provide an assessment of vestibular tone balance related to otolith function. This can be objectively quantified from fundus photographs using the disc-foveal angle (DFA). Because head tilt also physiologically alters ocular torsion through OCR, head position during fundus imaging may influence the measured DFA. Here, we examined this effect of head tilt and the resulting OCR on fundus-based measurements of ocular torsion. Methods: Ten healthy adults (age 28-45 y/o; 2 females) underwent bilateral fundus photography under three conditions: routine head placement, controlled upright (0°) positioning, and 10° lateral head tilt. Head orientation was continuously measured using a strap-mounted gyroscope. DFA was quantified from fundus images as the angle between the fovea-optic disc axis and horizontal meridian using ImageJ. Results: Mean DFA did not differ between standard and controlled head positioning (p = 0.23), although within-subject variability was greater with standard positioning (p = 0.020). In contrast, 10° head tilt significantly changed DFA (p < 0.01). Conclusions: Small, naturally occurring variations in head position do not significantly alter DFA but may increase measurement variability, whereas larger head tilts produce significant changes in DFA. Careful control of head position during fundus photography can improve the reliability of DFA measurements for assessment of otolith-ocular function.
SN - 2039-4330
SN - 2039-4349
ER -