Skip to content
DraconiticResearch
Search Sources API
186,546 studies31 sourcesUpdated 32 min ago
PreprintarXiv licencearXiv

Braided endovascular implants for intracranial aneurysms: mechanics, hemodynamics, and clinical translation

Abstract

Endovascular implants prevent intracranial aneurysm rupture by altering the mechanical and hemodynamic environment at the aneurysm neck. Yet many in silico workflows prescribe or reconstruct the post-deployment geometry before computing flow, leaving unresolved the mechanics that create the clinically relevant interface. Here we review braided intraluminal flow diverters, intrasaccular devices, and emerging flow-disruption concepts across deployment mechanics, inter-wire and wire-wall contact, superelasticity, wall apposition, pore geometry, computational fluid dynamics, and fluid-structure interaction. We connect these modeling choices to neck coverage, malapposition, migration, deformation, and durability, and distinguish established evidence from mechanistic inference and prospective hypotheses. We argue that model fidelity should match the clinical question: prescribed or fast placement may support screening, whereas questions of coverage, apposition, compaction, and migration benefit from mechanically plausible deployment states. An interface-resolved mechanics-to-flow framework, supported by measurable validation targets and standardized reporting, could improve device design and enable more reliable patient-specific treatment planning.

Related

  1. Effect of heart rate on hemodynamics in patient-specific intracranial aneurysms: An in vitro study
    Baha Al-Deen T El-Khader, Nikhil Shirdade, Jana Korte +4
    PLOS OnePeer-reviewedCC BYFull textCardiovascular medicineFluid dynamicsPLOSEurope PMCPMC
  2. Contact-resolved deployment of the Contour Neurovascular System in patient-specific intracranial aneurysms
    Ratnadeep Pramanik, Fina Gießler, Martin Frank +5
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationBiological & medical physicsarXiv
  3. In vitro characterization of intraventricular hemodynamics for patients supported by Impella 5.5
    Fanette Chassagne, Claudio Bravo, Jennifer Beckman +2
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  4. How does human blood rheology influence arterial and cardiovascular device hemodynamics? A comprehensive review, discussion, and future directions
    C. Sasmal
    arXivPreprintCC BY 4.0Full textBiological & medical physicsFluid dynamicsarXiv
  5. Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation
    Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
    arXivPreprintCC BY-SA 4.0Full textBiological & medical physicsFluid dynamicsarXiv
BibTeX
@misc{pramanik2026braided,
  title = {{Braided endovascular implants for intracranial aneurysms: mechanics, hemodynamics, and clinical translation}},
  author = {Ratnadeep Pramanik and Duygu Dengiz and Mariya S. Pravdivtseva and Martin Frank and Ivo Steinbrecher and Prasanth Velvaluri and Matthias Mayr and Philipp Berg and Sylvia Saalfeld and Naomi Larsen and Olav Jansen and Alexander Popp},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2609.18544},
  eprint = {2609.18544},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.18544},
}
RIS
TY  - UNPB
TI  - Braided endovascular implants for intracranial aneurysms: mechanics, hemodynamics, and clinical translation
AU  - Ratnadeep Pramanik
AU  - Duygu Dengiz
AU  - Mariya S. Pravdivtseva
AU  - Martin Frank
AU  - Ivo Steinbrecher
AU  - Prasanth Velvaluri
AU  - Matthias Mayr
AU  - Philipp Berg
AU  - Sylvia Saalfeld
AU  - Naomi Larsen
AU  - Olav Jansen
AU  - Alexander Popp
PY  - 2026
DA  - 2026/10/15
PB  - arXiv
DO  - 10.48550/arxiv.2609.18544
UR  - https://arxiv.org/abs/2609.18544
AB  - Endovascular implants prevent intracranial aneurysm rupture by altering the mechanical and hemodynamic environment at the aneurysm neck. Yet many in silico workflows prescribe or reconstruct the post-deployment geometry before computing flow, leaving unresolved the mechanics that create the clinically relevant interface. Here we review braided intraluminal flow diverters, intrasaccular devices, and emerging flow-disruption concepts across deployment mechanics, inter-wire and wire-wall contact, superelasticity, wall apposition, pore geometry, computational fluid dynamics, and fluid-structure interaction. We connect these modeling choices to neck coverage, malapposition, migration, deformation, and durability, and distinguish established evidence from mechanistic inference and prospective hypotheses. We argue that model fidelity should match the clinical question: prescribed or fast placement may support screening, whereas questions of coverage, apposition, compaction, and migration benefit from mechanically plausible deployment states. An interface-resolved mechanics-to-flow framework, supported by measurable validation targets and standardized reporting, could improve device design and enable more reliable patient-specific treatment planning.
ER  -