Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).
- 1Department of Medicine, University of Patras, 26504 Patras, Greece.
- 2Department of Civil Engineering, University of Patras, 26504 Patras, Greece.
Abstract
Indoor particulate matter is a Group 1 carcinogen with no identified exposure threshold, and the portable air cleaners now widely deployed in European schools, hospitals and offices are almost always evaluated by a change in mean concentration measured before and after installation in the same room. We applied a probabilistic incremental lifetime cancer risk (ILCR) framework to size-resolved particulate matter in thirteen occupied micro-environments in five countries, monitored continuously at five-minute resolution within the TwinAIR pilot network, and then tested that evaluation design against the measurements it rests on. Risk was uniformly low: every site-by-fraction estimate fell below the 10⁻⁶ de minimis threshold by between one and three orders of magnitude, and the conclusion survived recomputation from the measured concentration distributions (11.2 to 353 times below the threshold across forty-two estimates) and the substitution of paediatric exposure parameters. The evaluation design did not survive. In the two rooms that received air cleaners, measured PM2.5 rose by 7.8% and 21.0%, while a thermo-hygrometric regression explaining 1-6% of the variance-the concentration model underlying the probabilistic estimates-predicted reductions of 6.7% and 2.3%. Applying the same phase boundary to four sensors in three micro-environments that received no device produced changes from -74.3% to +37.2%, exceeding in magnitude and spanning in direction the contrast attributed to the intervention. The novelty of this work is therefore twofold: a harmonised probabilistic risk assessment of thirteen real occupied interiors on a single scale, and a demonstration, from the same network's data, that within-room pre-post designs without concurrent controls cannot identify an air-cleaning effect.
Related
- Participant Outcomes of the Diabetes and WELLbeing 12-Week Psychoeducational Self-Management Programme for Type 2 Diabetes: A Four-Country European Evaluation
- Effect of transitional nutrition in intake level of heavy metal from Iranian sauces consumption and its carcinogenic and health risks
- Evaluation of Traffic-Related Air Pollution Exposure in Sensitive Environments.
- Pharmacokinetics and Safety Evaluation of the Transglutaminase 2 Inhibitor Suvigletistat in Healthy Chinese, Japanese, and White/European Participants.
- Ultrasound Evaluation of Varicoceles: A Closed-Loop Audit of Compliance With European Society of Urogenital Radiology Guidelines
BibTeX
@article{chatziprodromidou2026particulatematter,
title = {{Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).}},
author = {Ioanna P Chatziprodromidou and Rafail Fokas and Angeliki Chatziantoniou and Kalypso Angeliki Koukouvini and Stylianos Karatzas and Apostolos Vantarakis and TwinAIR Consortium},
journal = {Toxics},
year = {2026},
month = oct,
doi = {10.3390/toxics14110937},
url = {https://europepmc.org/article/MED/43083547},
note = {CC BY},
}
RIS
TY - JOUR
TI - Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).
AU - Ioanna P Chatziprodromidou
AU - Rafail Fokas
AU - Angeliki Chatziantoniou
AU - Kalypso Angeliki Koukouvini
AU - Stylianos Karatzas
AU - Apostolos Vantarakis
AU - TwinAIR Consortium
PY - 2026
DA - 2026/10/23
JO - Toxics
DO - 10.3390/toxics14110937
UR - https://europepmc.org/article/MED/43083547
AB - Indoor particulate matter is a Group 1 carcinogen with no identified exposure threshold, and the portable air cleaners now widely deployed in European schools, hospitals and offices are almost always evaluated by a change in mean concentration measured before and after installation in the same room. We applied a probabilistic incremental lifetime cancer risk (ILCR) framework to size-resolved particulate matter in thirteen occupied micro-environments in five countries, monitored continuously at five-minute resolution within the TwinAIR pilot network, and then tested that evaluation design against the measurements it rests on. Risk was uniformly low: every site-by-fraction estimate fell below the 10⁻⁶ de minimis threshold by between one and three orders of magnitude, and the conclusion survived recomputation from the measured concentration distributions (11.2 to 353 times below the threshold across forty-two estimates) and the substitution of paediatric exposure parameters. The evaluation design did not survive. In the two rooms that received air cleaners, measured PM2.5 rose by 7.8% and 21.0%, while a thermo-hygrometric regression explaining 1-6% of the variance-the concentration model underlying the probabilistic estimates-predicted reductions of 6.7% and 2.3%. Applying the same phase boundary to four sensors in three micro-environments that received no device produced changes from -74.3% to +37.2%, exceeding in magnitude and spanning in direction the contrast attributed to the intervention. The novelty of this work is therefore twofold: a harmonised probabilistic risk assessment of thirteen real occupied interiors on a single scale, and a demonstration, from the same network's data, that within-room pre-post designs without concurrent controls cannot identify an air-cleaning effect.
SN - 2305-6304
ER -