Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BYToxics

Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).

  1. 1Department of Medicine, University of Patras, 26504 Patras, Greece.
  2. 2Department of Civil Engineering, University of Patras, 26504 Patras, Greece.

Abstract

Indoor particulate matter is a Group 1 carcinogen with no identified exposure threshold, and the portable air cleaners now widely deployed in European schools, hospitals and offices are almost always evaluated by a change in mean concentration measured before and after installation in the same room. We applied a probabilistic incremental lifetime cancer risk (ILCR) framework to size-resolved particulate matter in thirteen occupied micro-environments in five countries, monitored continuously at five-minute resolution within the TwinAIR pilot network, and then tested that evaluation design against the measurements it rests on. Risk was uniformly low: every site-by-fraction estimate fell below the 10⁻⁶ de minimis threshold by between one and three orders of magnitude, and the conclusion survived recomputation from the measured concentration distributions (11.2 to 353 times below the threshold across forty-two estimates) and the substitution of paediatric exposure parameters. The evaluation design did not survive. In the two rooms that received air cleaners, measured PM2.5 rose by 7.8% and 21.0%, while a thermo-hygrometric regression explaining 1-6% of the variance-the concentration model underlying the probabilistic estimates-predicted reductions of 6.7% and 2.3%. Applying the same phase boundary to four sensors in three micro-environments that received no device produced changes from -74.3% to +37.2%, exceeding in magnitude and spanning in direction the contrast attributed to the intervention. The novelty of this work is therefore twofold: a harmonised probabilistic risk assessment of thirteen real occupied interiors on a single scale, and a demonstration, from the same network's data, that within-room pre-post designs without concurrent controls cannot identify an air-cleaning effect.

Related

  1. Participant Outcomes of the Diabetes and WELLbeing 12-Week Psychoeducational Self-Management Programme for Type 2 Diabetes: A Four-Country European Evaluation
    A. Mukherjee, S. S. Shergill, S. Hotham +5
    medRxivPreprintAll rights reservedFull textEndocrinology & metabolismmedRxiv
  2. Effect of transitional nutrition in intake level of heavy metal from Iranian sauces consumption and its carcinogenic and health risks
    Javad Torkashvand, Sajad Torkashvand, Fardin Tamjidi
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPharmacology & toxicologyCrossref
  3. Evaluation of Traffic-Related Air Pollution Exposure in Sensitive Environments.
    Matthias Karl, Saba Manzoor
    ToxicsPeer-reviewedCC BYFull textPharmacology & toxicologyEurope PMC
  4. Pharmacokinetics and Safety Evaluation of the Transglutaminase 2 Inhibitor Suvigletistat in Healthy Chinese, Japanese, and White/European Participants.
    Romina A Nand, Hannah Woodcock, Kasia A Okrojek-Swiderek +3
    Clinical pharmacology in drug developmentPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Ultrasound Evaluation of Varicoceles: A Closed-Loop Audit of Compliance With European Society of Urogenital Radiology Guidelines
    Hamza A Khan, Kethesparan Paramesparan
    CureusPeer-reviewedCC BYFull textMedical imaging & radiologyEurope PMCEurope PMCPMC
BibTeX
@article{chatziprodromidou2026particulatematter,
  title = {{Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).}},
  author = {Ioanna P Chatziprodromidou and Rafail Fokas and Angeliki Chatziantoniou and Kalypso Angeliki Koukouvini and Stylianos Karatzas and Apostolos Vantarakis and TwinAIR Consortium},
  journal = {Toxics},
  year = {2026},
  month = oct,
  doi = {10.3390/toxics14110937},
  url = {https://europepmc.org/article/MED/43083547},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).
AU  - Ioanna P Chatziprodromidou
AU  - Rafail Fokas
AU  - Angeliki Chatziantoniou
AU  - Kalypso Angeliki Koukouvini
AU  - Stylianos Karatzas
AU  - Apostolos Vantarakis
AU  - TwinAIR Consortium
PY  - 2026
DA  - 2026/10/23
JO  - Toxics
DO  - 10.3390/toxics14110937
UR  - https://europepmc.org/article/MED/43083547
AB  - Indoor particulate matter is a Group 1 carcinogen with no identified exposure threshold, and the portable air cleaners now widely deployed in European schools, hospitals and offices are almost always evaluated by a change in mean concentration measured before and after installation in the same room. We applied a probabilistic incremental lifetime cancer risk (ILCR) framework to size-resolved particulate matter in thirteen occupied micro-environments in five countries, monitored continuously at five-minute resolution within the TwinAIR pilot network, and then tested that evaluation design against the measurements it rests on. Risk was uniformly low: every site-by-fraction estimate fell below the 10⁻⁶ de minimis threshold by between one and three orders of magnitude, and the conclusion survived recomputation from the measured concentration distributions (11.2 to 353 times below the threshold across forty-two estimates) and the substitution of paediatric exposure parameters. The evaluation design did not survive. In the two rooms that received air cleaners, measured PM2.5 rose by 7.8% and 21.0%, while a thermo-hygrometric regression explaining 1-6% of the variance-the concentration model underlying the probabilistic estimates-predicted reductions of 6.7% and 2.3%. Applying the same phase boundary to four sensors in three micro-environments that received no device produced changes from -74.3% to +37.2%, exceeding in magnitude and spanning in direction the contrast attributed to the intervention. The novelty of this work is therefore twofold: a harmonised probabilistic risk assessment of thirteen real occupied interiors on a single scale, and a demonstration, from the same network's data, that within-room pre-post designs without concurrent controls cannot identify an air-cleaning effect.
SN  - 2305-6304
ER  -