Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYMembranes

Pairing Initial and Residual Permeability Loss to Assess Persistent Hydraulic Impairment in Ceramic Nanofiltration.

  1. 1School of Water Conservancy and Environment, University of Jinan, Jinan 250022, China.
  2. 2Section of Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, Stevinweg 1, 2628 CN Delft, The Netherlands.

Abstract

Early permeability decline integrates both recoverable hydraulic effects and persistent membrane impairment, which limits its interpretation as a stand-alone fouling indicator. In this study, we evaluated whether pairing initial permeability loss (IPL) with post-exposure residual permeability loss could distinguish the magnitude and persistence of early hydraulic responses during ceramic nanofiltration. Six water matrices-drinking water, river water, reservoir water, secondary effluent, sodium alginate (SA), and sodium alginate supplemented with calcium (SA+Ca)-were examined using a 60 min early-response window, a defined deionized-water recovery procedure, and 8 h filtration trajectories. Apparent IPL ranged from 2.05% to 76.04%, whereas residual IPL ranged from 1.26% to 41.38%. Across the six matrix means, apparent and residual IPL were strongly associated (R² = 0.948), while dissolved organic carbon was associated with apparent IPL (R² = 0.871). Despite nearly identical measured organic carbon concentrations, the SA+Ca formulation showed apparent and residual losses that were 20.28 and 16.34 percentage points higher, respectively, than those of SA. Residual loss also increased progressively with exposure time, indicating that persistent impairment developed within the initial filtration period. Together, paired apparent and residual IPL provide an operational means of comparing early hydraulic-response magnitude and post-recovery persistence across water matrices under fixed membrane and operating conditions.

Related

  1. Connected, but for how long? A residual-lifetime criterion for the hydraulic–diffusive boundary in polyamide reverse-osmosis membranes
    Ye. O. Kolomiiets, Yevhen Kolomiiets
    ChemRxivPreprintCC BYFull textHydrology & soilsChemRxiv
  2. Persistent residual ellipticity in waveplate-compensated polarization-resolved SHG microscopy on a commercial multiphoton microscope
    David Nguyen, Jeffrey P. Wilde, Virginie Uhlmann +5
    PLOS OnePeer-reviewedCC BY 4.0Materials & polymersGeology & geochemistryPLOS
  3. Molecular oxygen confinement ladder enables stable electro-Fenton treatment of nanofiltration concentrate
    Yufei Cheng, Mengzhuang Yang, Yuchen Hu +9
    Environmental Science and EcotechnologyPeer-reviewedCC BYFull textHydrology & soilsDOAJ
  4. Life Cycle Impact Assessment of Pesticides Removal from Water Using Nanofiltration and Reverse Osmosis.
    Anica Pavlinović, Iva Ćurić, Davor Dolar
    MembranesPeer-reviewedCC BYFull textEnvironmental science & pollutionEurope PMC
  5. Digital-Assisted Workflow for Organic Solvent Nanofiltration: Accelerating Process Development in Pharmaceutical Manufacturing
    Yiran Li, Ida F Amura, Petros Neoptolemou +1
    Organic process research & developmentPeer-reviewedCC BYFull textHydrology & soilsEurope PMCEurope PMC
BibTeX
@article{xie2026pairing,
  title = {{Pairing Initial and Residual Permeability Loss to Assess Persistent Hydraulic Impairment in Ceramic Nanofiltration.}},
  author = {Xuan Xie and Yuke Li},
  journal = {Membranes},
  year = {2026},
  month = oct,
  doi = {10.3390/membranes16110357},
  url = {https://europepmc.org/article/MED/43083183},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Pairing Initial and Residual Permeability Loss to Assess Persistent Hydraulic Impairment in Ceramic Nanofiltration.
AU  - Xuan Xie
AU  - Yuke Li
PY  - 2026
DA  - 2026/10/25
JO  - Membranes
DO  - 10.3390/membranes16110357
UR  - https://europepmc.org/article/MED/43083183
AB  - Early permeability decline integrates both recoverable hydraulic effects and persistent membrane impairment, which limits its interpretation as a stand-alone fouling indicator. In this study, we evaluated whether pairing initial permeability loss (IPL) with post-exposure residual permeability loss could distinguish the magnitude and persistence of early hydraulic responses during ceramic nanofiltration. Six water matrices-drinking water, river water, reservoir water, secondary effluent, sodium alginate (SA), and sodium alginate supplemented with calcium (SA+Ca)-were examined using a 60 min early-response window, a defined deionized-water recovery procedure, and 8 h filtration trajectories. Apparent IPL ranged from 2.05% to 76.04%, whereas residual IPL ranged from 1.26% to 41.38%. Across the six matrix means, apparent and residual IPL were strongly associated (R² = 0.948), while dissolved organic carbon was associated with apparent IPL (R² = 0.871). Despite nearly identical measured organic carbon concentrations, the SA+Ca formulation showed apparent and residual losses that were 20.28 and 16.34 percentage points higher, respectively, than those of SA. Residual loss also increased progressively with exposure time, indicating that persistent impairment developed within the initial filtration period. Together, paired apparent and residual IPL provide an operational means of comparing early hydraulic-response magnitude and post-recovery persistence across water matrices under fixed membrane and operating conditions.
SN  - 2077-0375
ER  -