Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 16 min ago
Peer-reviewedCC BYMethods and protocols

Comparison of Dual-Luciferase® Reporter Assay and a Stably Transfected NF-κB Reporter Cell Line for Detecting TNF-α and X-Ray-Induced Pathway Activation.

  1. 1Aeromedical FabLab, Institute of Aerospace Medicine, German Aerospace Center (DLR), 51147 Cologne, Germany.
  2. 2Radiation Biology, Institute of Aerospace Medicine, German Aerospace Center (DLR), 51147 Cologne, Germany.
  3. 3Bundesamt für Strahlenschutz (BfS)-Federal Office for Radiation Protection, Optical Radiation, 85764 Oberschleißheim, Germany.

Abstract

The transcription factor nuclear factor kappa B (NF-κB) is a central regulator of inflammatory and genotoxic stress responses and is involved in immune function and disease pathogenesis. Reporter assays are widely used to quantify NF-κB activation, yet systematic benchmarks between transient dual-luciferase and stable fluorescent formats under harmonized conditions are lacking. We compared a transient Dual-Luciferase® Reporter (DLRTM) assay in HEK293 cells with the stably transfected HEK-pNF-κB-d2EGFP/Neo L2 cell line using recombinant TNF-α and X-rays as stimuli. Dynamic range, limit of detection (LOD), signal-to-noise ratio (S/N), and half-maximal effective concentrations and doses (EC₅₀, ED₅₀) were derived from four-parameter logistic modeling. The HEK-pNF-κB-d2EGFP/Neo L2 line showed higher sensitivity to TNF-α (EC₅₀ = 0.31 ng/mL) than the DLRTM assay (1.2-2.0 ng/mL) and a lower LOD, whereas the DLRTM assay provided better temporal resolution, revealing assay-specific signal decline attributable to reporter stability and readout kinetics. For X-ray exposure, both systems showed comparable potency (EC₅₀ ≈ 5-8 Gy), while the stable cell line maintained superior S/N. Both reporter systems support high-throughput and mechanistic applications: the DLRTM assay offers versatility across cell types, while the HEK-pNF-κB-d2EGFP/Neo L2 line provides higher sensitivity, dynamic range, and single-cell resolution.

Related

  1. Comparison of an AI-enabled single-lead ECG monitor and point-of-care testing for detecting intradialytic hypokalemia
    Wen-Fang Chiang, Po-Jen Hsiao, Kun-Lin Wu +4
    Renal FailurePeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
  2. Detecting and Characterising Autonomic Dysfunction in Chronic Musculoskeletal Pain: A Cross-Sectional Comparison with Pain-Free Controls
    Norah A. Almutairi, Darren C. Greenwood, Manoj Sivan
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
  3. Detecting epidemic outbreaks with routine blood tests: A comparison of surveillance methods using COVID-19 simulations and real-world seasonal disease data
    K. A. Klochkov, I. I. Maslova, E. N. Ilina +1
    medRxivPreprintCC BYFull textEpidemiology & public healthmedRxiv
  4. Comparison of lung ultrasonography and chest radiography in detecting neonatal respiratory distress as a composite clinical condition: a prospective cross-sectional diagnostic accuracy study at Muhimbili National Hospital
    Hollo K. Dadi, Balowa Musa Baraka, Irene H. Mhalu +1
    BMC PediatricsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  5. Dilution‐Endpoint Comparison of a Flow Cytometric Platelet Activation Assay With PF4/Heparin ELISA and a Lateral Flow Immunoassay in Suspected HIT
    Elvira Maličev, Matjaž Urbajs, Katerina Jazbec Gradišar +2
    International Journal of Laboratory HematologyPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
BibTeX
@article{feles2026comparison,
  title = {{Comparison of Dual-Luciferase® Reporter Assay and a Stably Transfected NF-κB Reporter Cell Line for Detecting TNF-α and X-Ray-Induced Pathway Activation.}},
  author = {Sebastian Feles and Sebastian Diegeler and Bernd Henschenmacher and Christa Baumstark-Khan and Christine Elisabeth Hellweg},
  journal = {Methods and protocols},
  year = {2026},
  month = nov,
  doi = {10.3390/mps9060164},
  url = {https://europepmc.org/article/MED/43081608},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Comparison of Dual-Luciferase® Reporter Assay and a Stably Transfected NF-κB Reporter Cell Line for Detecting TNF-α and X-Ray-Induced Pathway Activation.
AU  - Sebastian Feles
AU  - Sebastian Diegeler
AU  - Bernd Henschenmacher
AU  - Christa Baumstark-Khan
AU  - Christine Elisabeth Hellweg
PY  - 2026
DA  - 2026/11/09
JO  - Methods and protocols
DO  - 10.3390/mps9060164
UR  - https://europepmc.org/article/MED/43081608
AB  - The transcription factor nuclear factor kappa B (NF-κB) is a central regulator of inflammatory and genotoxic stress responses and is involved in immune function and disease pathogenesis. Reporter assays are widely used to quantify NF-κB activation, yet systematic benchmarks between transient dual-luciferase and stable fluorescent formats under harmonized conditions are lacking. We compared a transient Dual-Luciferase® Reporter (DLRTM) assay in HEK293 cells with the stably transfected HEK-pNF-κB-d2EGFP/Neo L2 cell line using recombinant TNF-α and X-rays as stimuli. Dynamic range, limit of detection (LOD), signal-to-noise ratio (S/N), and half-maximal effective concentrations and doses (EC₅₀, ED₅₀) were derived from four-parameter logistic modeling. The HEK-pNF-κB-d2EGFP/Neo L2 line showed higher sensitivity to TNF-α (EC₅₀ = 0.31 ng/mL) than the DLRTM assay (1.2-2.0 ng/mL) and a lower LOD, whereas the DLRTM assay provided better temporal resolution, revealing assay-specific signal decline attributable to reporter stability and readout kinetics. For X-ray exposure, both systems showed comparable potency (EC₅₀ ≈ 5-8 Gy), while the stable cell line maintained superior S/N. Both reporter systems support high-throughput and mechanistic applications: the DLRTM assay offers versatility across cell types, while the HEK-pNF-κB-d2EGFP/Neo L2 line provides higher sensitivity, dynamic range, and single-cell resolution.
SN  - 2409-9279
ER  -