An Inline‐Integrable Image Restoration Model With ROI Fine‐Tuning and Slice‐to‐Volume Reconstruction for Accelerated Whole‐Brain Vessel Wall Imaging
9 affiliations
- 1Department of Radiology University of Southern California Los Angeles California USA
- 2Department of Biomedical Engineering University of Southern California Los Angeles California USA
- 3Department of Bioengineering University of California Los Angeles, California Los Angeles California USA
- 4Department of Radiology Anzhen Hospital Beijing China
- 5Department of Radiology Chaoyang Hospital Beijing China
- 6Siemens Medical Solutions Los Angeles California USA
- 7GE HealthCare Beijing China
- 8Department of Neurological Surgery University of Southern California Los Angeles California USA
- 9Department of Radiology and Biomedical Imaging University of California San Francisco San Francisco California USA
Abstract
Purpose: To develop a vessel wall imaging (VWI)‐dedicated image restoration model enabling high‐resolution whole‐brain VWI in under 6 min.
Methods: A transformer‐based 2.5D model was trained in a supervised manner to enhance the image quality of CAIPIRINHA 2 × 2‐accelerated VWI acquisitions to a level comparable to that of GRAPPA twofold‐accelerated scans. The majority of k‐space data used for training and testing were acquired on a Siemens 3 T system equipped with a standard 20‐channel head–neck coil. Region‐of‐interest fine‐tuning and slice‐to‐volume reconstruction were devised to balance global structural fidelity with local vascular precision and 3D continuity. Model performance was evaluated both quantitatively and qualitatively through single‐center retrospective testing and prospective testing in multi‐center, generalized settings. Integration of the model into the vendor's inline image reconstruction pipeline was also investigated.
Results: Compared with the input images, model outputs improved peak SNR by more than 7 dB and structural similarity index measure by 0.19 in the retrospective test set. When applied to CAIPIRINHA fourfold‐accelerated data that otherwise underwent offline or inline GRAPPA reconstruction, the model significantly enhanced vessel wall SNR, wall‐to‐lumen CNR, wall‐to‐cerebrospinal fluid CNR, and image quality scores. These improvements were sustained in an independent cohort from different institutions and reproduced in a dataset acquired with smaller field of view and a 64‐channel coil, supporting the model's robustness and generalizability.
Conclusion: The proposed inline‐integrable image restoration model enables clinically viable whole‐brain VWI in under 6 min using standard 20‐channel coils, offering a practical approach to improve patient throughput without compromising diagnostic quality.
Related
- Evaluation of accelerated whole-body diffusion weighted imaging with deep learning reconstruction in patients with metastatic prostate cancer: assessment of image quality and ADC estimates.
- Image quality of combined PROPELLER and deep learning reconstruction using an accelerated T2-weighted imaging technique for prostate MRI.
- Learning optimized sampling patterns for accelerated MRI reconstruction via diffusion models
- Effects of Artificial Intelligence–based Reconstruction on Image Quality and Voxel-based Morphometry Analysis of Atrophy in Accelerated MPRAGE
- Evaluation of a Deep Learning Reconstruction Technique for Accelerated Brain MRI Scans.
BibTeX
@article{wang2026inlineintegrable,
title = {{An Inline‐Integrable Image Restoration Model With ROI Fine‐Tuning and Slice‐to‐Volume Reconstruction for Accelerated Whole‐Brain Vessel Wall Imaging}},
author = {Pengcheng Wang and Jingxiang Zhang and Jiayu Xiao and Junzhou Chen and Zhenjia Wang and Jin Li and Qingle Kong and Steven Y. Cen and Sophia X. Cui and Yifei Zhang and Wei Yu and Qi Yang and Nasim Sheikh‐Bahaei and William J. Mack and Zhaoyang Fan},
journal = {Magnetic Resonance in Medicine},
year = {2026},
month = oct,
doi = {10.1002/mrm.70594},
url = {https://doi.org/10.1002/mrm.70594},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - An Inline‐Integrable Image Restoration Model With ROI Fine‐Tuning and Slice‐to‐Volume Reconstruction for Accelerated Whole‐Brain Vessel Wall Imaging
AU - Pengcheng Wang
AU - Jingxiang Zhang
AU - Jiayu Xiao
AU - Junzhou Chen
AU - Zhenjia Wang
AU - Jin Li
AU - Qingle Kong
AU - Steven Y. Cen
AU - Sophia X. Cui
AU - Yifei Zhang
AU - Wei Yu
AU - Qi Yang
AU - Nasim Sheikh‐Bahaei
AU - William J. Mack
AU - Zhaoyang Fan
PY - 2026
DA - 2026/10/08
JO - Magnetic Resonance in Medicine
DO - 10.1002/mrm.70594
UR - https://doi.org/10.1002/mrm.70594
AB - Purpose: To develop a vessel wall imaging (VWI)‐dedicated image restoration model enabling high‐resolution whole‐brain VWI in under 6 min. Methods: A transformer‐based 2.5D model was trained in a supervised manner to enhance the image quality of CAIPIRINHA 2 × 2‐accelerated VWI acquisitions to a level comparable to that of GRAPPA twofold‐accelerated scans. The majority of k‐space data used for training and testing were acquired on a Siemens 3 T system equipped with a standard 20‐channel head–neck coil. Region‐of‐interest fine‐tuning and slice‐to‐volume reconstruction were devised to balance global structural fidelity with local vascular precision and 3D continuity. Model performance was evaluated both quantitatively and qualitatively through single‐center retrospective testing and prospective testing in multi‐center, generalized settings. Integration of the model into the vendor's inline image reconstruction pipeline was also investigated. Results: Compared with the input images, model outputs improved peak SNR by more than 7 dB and structural similarity index measure by 0.19 in the retrospective test set. When applied to CAIPIRINHA fourfold‐accelerated data that otherwise underwent offline or inline GRAPPA reconstruction, the model significantly enhanced vessel wall SNR, wall‐to‐lumen CNR, wall‐to‐cerebrospinal fluid CNR, and image quality scores. These improvements were sustained in an independent cohort from different institutions and reproduced in a dataset acquired with smaller field of view and a 64‐channel coil, supporting the model's robustness and generalizability. Conclusion: The proposed inline‐integrable image restoration model enables clinically viable whole‐brain VWI in under 6 min using standard 20‐channel coils, offering a practical approach to improve patient throughput without compromising diagnostic quality.
SN - 0740-3194
SN - 1522-2594
ER -