Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BYPLOS One

Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study

4 affiliations
  1. 1Department of Surgery, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.
  2. 2Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
  3. 3Intensive Care Department, Catharina Hospital, Eindhoven, Netherlands.
  4. 4Department of Anesthesiology, Catharina Hospital Eindhoven, Eindhoven, The Netherlands.

Abstract

Background: Continuous wearable monitoring of vital signs is increasingly implemented on hospital wards to enable early detection of clinical deterioration and to reduce the burden of intermittent vital-sign measurements. While feasibility of wearable monitoring and its acceptance among healthcare professionals have been demonstrated, patient perspectives remain underexplored. Objective: To evaluate patient experiences with wearable monitoring devices during hospitalization. Methods: This prospective, single-center mixed-methods study included adult surgical ward patients monitored with a wearable device (Healthdot or viQtor) for ≥ 24 hours. Patients completed 15 five-point Likert items assessing patient experience and a separate overall satisfaction rating on a 1–10 scale. Qualitative material comprised free-text responses from 36 of the 102 participants and two additional semistructured interviews with participants from the same cohort. Quantitative data were analyzed using descriptive statistics, reliability analysis, exploratory monitoring-context comparisons, and multivariable regression. Qualitative data were analyzed using Braun and Clarke’s thematic-analysis approach. Results: A total of 102 patients were included in the final analysis after exclusion of two duplicate questionnaire records. Mean overall acceptance was 4.05 ± 0.54 on a 1–5 scale (95% CI 3.94–4.15), and mean satisfaction was 8.21 ± 1.39 on a 1–10 scale (95% CI 7.93–8.48). Acceptance was higher in the Healthdot context than in the viQtor context, with an exploratory mean difference of 0.40 points (95% CI 0.18–0.62). Qualitative findings indicated generally limited burden, but also concerns regarding comfort and patient information. Conclusions: Patients in this single-center cohort generally reported favorable experiences with continuous wearable vital-sign monitoring. Acceptance differed between the two monitoring contexts, but the study design does not allow these differences to be attributed to a causal effect of device type. Further studies should validate the questionnaire and evaluate clinical effectiveness, safety, cost-effectiveness, and longer-term implementation outcomes.

Related

  1. Development of a Wearable Sensor-PAM for Continuous Monitoring of Photosynthetic Dynamics
    K.-i. Miyamoto, K. Ifuku, T. Yoshinobu +1
    bioRxivPreprintCC BY-NC-NDFull textPlant biologybioRxiv
  2. Frequency modulated semi-continuous wave Doppler ultrasound: A novel method for the detection of scatterer velocity and range using wearable ultrasound instrumentation
    C. M. Delaney, A. Bashatah, A. Aher +4
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  3. Capturing continuous spectrotemporal pupil--brain coupling with simultaneous wearable EEG/Eye tracking
    T. Liu, S. A. Kotz, M. Schwartze +1
    bioRxivPreprintCC BY-NCFull textNeurosciencebioRxiv
  4. Validation of a fully integrated in-ear EEG wearable device for monitoring resting-state alpha activity and auditory steady-state responses
    J. Y. Juez-Suárez, F. Segura-Quijano, M. Le Van Quyen +2
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0NeuroscienceFrontiersCrossref
  5. Compact target-aware stability-based feature selection for cross-dataset wearable activity monitoring
    Sarra Ayouni, Maha Sliti, Abeer Abdulaziz Alghanem +2
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
BibTeX
@article{jerry2026patient,
  title = {{Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study}},
  author = {Ephrahim E Jerry and Daphne L J Nabben and Ashley J R De Bie Dekker and Igor W F Paulussen and R Arthur Bouwman and Simon W Nienhuijs},
  journal = {PLOS One},
  year = {2026},
  month = nov,
  doi = {10.1371/journal.pone.0363253},
  url = {https://doi.org/10.1371/journal.pone.0363253},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study
AU  - Ephrahim E Jerry
AU  - Daphne L J Nabben
AU  - Ashley J R De Bie Dekker
AU  - Igor W F Paulussen
AU  - R Arthur Bouwman
AU  - Simon W Nienhuijs
PY  - 2026
DA  - 2026/11/23
JO  - PLOS One
DO  - 10.1371/journal.pone.0363253
UR  - https://doi.org/10.1371/journal.pone.0363253
AB  - Background: Continuous wearable monitoring of vital signs is increasingly implemented on hospital wards to enable early detection of clinical deterioration and to reduce the burden of intermittent vital-sign measurements. While feasibility of wearable monitoring and its acceptance among healthcare professionals have been demonstrated, patient perspectives remain underexplored. Objective: To evaluate patient experiences with wearable monitoring devices during hospitalization. Methods: This prospective, single-center mixed-methods study included adult surgical ward patients monitored with a wearable device (Healthdot or viQtor) for ≥ 24 hours. Patients completed 15 five-point Likert items assessing patient experience and a separate overall satisfaction rating on a 1–10 scale. Qualitative material comprised free-text responses from 36 of the 102 participants and two additional semistructured interviews with participants from the same cohort. Quantitative data were analyzed using descriptive statistics, reliability analysis, exploratory monitoring-context comparisons, and multivariable regression. Qualitative data were analyzed using Braun and Clarke’s thematic-analysis approach. Results: A total of 102 patients were included in the final analysis after exclusion of two duplicate questionnaire records. Mean overall acceptance was 4.05 ± 0.54 on a 1–5 scale (95% CI 3.94–4.15), and mean satisfaction was 8.21 ± 1.39 on a 1–10 scale (95% CI 7.93–8.48). Acceptance was higher in the Healthdot context than in the viQtor context, with an exploratory mean difference of 0.40 points (95% CI 0.18–0.62). Qualitative findings indicated generally limited burden, but also concerns regarding comfort and patient information. Conclusions: Patients in this single-center cohort generally reported favorable experiences with continuous wearable vital-sign monitoring. Acceptance differed between the two monitoring contexts, but the study design does not allow these differences to be attributed to a causal effect of device type. Further studies should validate the questionnaire and evaluate clinical effectiveness, safety, cost-effectiveness, and longer-term implementation outcomes.
SN  - 1932-6203
ER  -