Validation of a fully integrated in-ear EEG wearable device for monitoring resting-state alpha activity and auditory steady-state responses
Abstract
This study evaluates the performance of a fully integrated in-ear EEG device by comparing it with simultaneous clinical-grade scalp EEG recordings in 29 healthy adults. The analysis focused on two electrophysiological markers: resting-state alpha activity (8–12 Hz) and auditory steady-state responses (ASSRs). ASSRs were tested using both single-frequency stimulation (40 Hz and 80 Hz) and more complex multi-frequency chirp configurations. A significant alpha peak was detected in the in-ear recordings of 15 of 29 participants (52%), compared with 83–100% for the scalp derivations. In-ear alpha peak power and signal-to-noise ratio were significantly correlated with scalp EEG at all six scalp derivations, indicating that the device preserves inter-individual differences in alpha strength despite reduced signal amplitude. The in-ear device recovered the group-level alpha frequency, but agreement with scalp EEG for individual alpha frequency (IAF) was limited. ASSR performance depended strongly on the stimulation paradigm. In-ear ASSR detection rates were lower than scalp rates at both modulation frequencies; at the two highest intensities, they reached 39–44% of the rate of the ipsilateral temporal scalp derivations at 40 Hz and 74–75% at 80 Hz. More complex multi-frequency stimulation resulted in a marked reduction in detection performance in both recording modalities. Overall, in a short controlled laboratory session, the fully integrated in-ear EEG system captured resting-state alpha activity and detected auditory steady-state responses under simple stimulation conditions in a subset of participants.
Related
- Compact target-aware stability-based feature selection for cross-dataset wearable activity monitoring
- Development of a Wearable Sensor-PAM for Continuous Monitoring of Photosynthetic Dynamics
- UniHAR: A unified hierarchical transformer with multi-scale temporal modeling for wearable human activity recognition
- Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study
- A randomised feasibility trial of VR-enhanced cue exposure therapy versus neutral VR exposure for cocaine use disorder, with wearable monitoring and JITA-EMA: Feasibility randomised controlled trial protocol
BibTeX
@article{juezsuarez2026validation,
title = {{Validation of a fully integrated in-ear EEG wearable device for monitoring resting-state alpha activity and auditory steady-state responses}},
author = {J. Y. Juez-Suárez and F. Segura-Quijano and M. Le Van Quyen and M. Valderrama and M. Nassar},
journal = {Frontiers in Neuroscience},
year = {2026},
month = nov,
doi = {10.3389/fnins.2026.1992412},
url = {https://www.frontiersin.org/articles/10.3389/fnins.2026.1992412},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Validation of a fully integrated in-ear EEG wearable device for monitoring resting-state alpha activity and auditory steady-state responses
AU - J. Y. Juez-Suárez
AU - F. Segura-Quijano
AU - M. Le Van Quyen
AU - M. Valderrama
AU - M. Nassar
PY - 2026
DA - 2026/11/17
JO - Frontiers in Neuroscience
DO - 10.3389/fnins.2026.1992412
UR - https://www.frontiersin.org/articles/10.3389/fnins.2026.1992412
AB - This study evaluates the performance of a fully integrated in-ear EEG device by comparing it with simultaneous clinical-grade scalp EEG recordings in 29 healthy adults. The analysis focused on two electrophysiological markers: resting-state alpha activity (8–12 Hz) and auditory steady-state responses (ASSRs). ASSRs were tested using both single-frequency stimulation (40 Hz and 80 Hz) and more complex multi-frequency chirp configurations. A significant alpha peak was detected in the in-ear recordings of 15 of 29 participants (52%), compared with 83–100% for the scalp derivations. In-ear alpha peak power and signal-to-noise ratio were significantly correlated with scalp EEG at all six scalp derivations, indicating that the device preserves inter-individual differences in alpha strength despite reduced signal amplitude. The in-ear device recovered the group-level alpha frequency, but agreement with scalp EEG for individual alpha frequency (IAF) was limited. ASSR performance depended strongly on the stimulation paradigm. In-ear ASSR detection rates were lower than scalp rates at both modulation frequencies; at the two highest intensities, they reached 39–44% of the rate of the ipsilateral temporal scalp derivations at 40 Hz and 74–75% at 80 Hz. More complex multi-frequency stimulation resulted in a marked reduction in detection performance in both recording modalities. Overall, in a short controlled laboratory session, the fully integrated in-ear EEG system captured resting-state alpha activity and detected auditory steady-state responses under simple stimulation conditions in a subset of participants.
SN - 1662-453X
ER -