Validation of a fully integrated in-ear EEG wearable device for monitoring resting-state alpha activity and auditory steady-state responses

Abstract

This study evaluates the performance of a fully integrated in-ear EEG device by comparing it with simultaneous clinical-grade scalp EEG recordings in 29 healthy adults. The analysis focused on two electrophysiological markers: resting-state alpha activity (8–12 Hz) and auditory steady-state responses (ASSRs). ASSRs were tested using both single-frequency stimulation (40 Hz and 80 Hz) and more complex multi-frequency chirp configurations. A significant alpha peak was detected in the in-ear recordings of 15 of 29 participants (52%), compared with 83–100% for the scalp derivations. In-ear alpha peak power and signal-to-noise ratio were significantly correlated with scalp EEG at all six scalp derivations, indicating that the device preserves inter-individual differences in alpha strength despite reduced signal amplitude. The in-ear device recovered the group-level alpha frequency, but agreement with scalp EEG for individual alpha frequency (IAF) was limited. ASSR performance depended strongly on the stimulation paradigm. In-ear ASSR detection rates were lower than scalp rates at both modulation frequencies; at the two highest intensities, they reached 39–44% of the rate of the ipsilateral temporal scalp derivations at 40 Hz and 74–75% at 80 Hz. More complex multi-frequency stimulation resulted in a marked reduction in detection performance in both recording modalities. Overall, in a short controlled laboratory session, the fully integrated in-ear EEG system captured resting-state alpha activity and detected auditory steady-state responses under simple stimulation conditions in a subset of participants.

Related

  1. Compact target-aware stability-based feature selection for cross-dataset wearable activity monitoring
    Sarra Ayouni, Maha Sliti, Abeer Abdulaziz Alghanem +2
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
  2. Development of a Wearable Sensor-PAM for Continuous Monitoring of Photosynthetic Dynamics
    K.-i. Miyamoto, K. Ifuku, T. Yoshinobu +1
    bioRxivPreprintCC BY-NC-NDFull textPlant biologybioRxiv
  3. UniHAR: A unified hierarchical transformer with multi-scale temporal modeling for wearable human activity recognition
    Memoona, Muhammad Haseeb Hashir, Sung Won Kim
    PLOS OnePeer-reviewedCC BYFull textNeuroscienceStatisticsPLOSEurope PMCPMC
  4. Patient acceptance of continuous wearable vital-sign monitoring on surgical wards: A prospective mixed-methods survey study
    Ephrahim E Jerry, Daphne L J Nabben, Ashley J R De Bie Dekker +3
    PLOS OnePeer-reviewedCC BYFull textSystems & synthetic biologyOncologyPLOSEurope PMC
  5. A randomised feasibility trial of VR-enhanced cue exposure therapy versus neutral VR exposure for cocaine use disorder, with wearable monitoring and JITA-EMA: Feasibility randomised controlled trial protocol
    Eileen Brobbin, Matteo Cella, Alexandre Copello +17
    PLOS OnePeer-reviewedCC BYFull textGeneral biologyGeneral chemistryPLOSEurope PMCPMC
BibTeX
@article{juezsuarez2026validation,
  title = {{Validation of a fully integrated in-ear EEG wearable device for monitoring resting-state alpha activity and auditory steady-state responses}},
  author = {J. Y. Juez-Suárez and F. Segura-Quijano and M. Le Van Quyen and M. Valderrama and M. Nassar},
  journal = {Frontiers in Neuroscience},
  year = {2026},
  month = nov,
  doi = {10.3389/fnins.2026.1992412},
  url = {https://www.frontiersin.org/articles/10.3389/fnins.2026.1992412},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Validation of a fully integrated in-ear EEG wearable device for monitoring resting-state alpha activity and auditory steady-state responses
AU  - J. Y. Juez-Suárez
AU  - F. Segura-Quijano
AU  - M. Le Van Quyen
AU  - M. Valderrama
AU  - M. Nassar
PY  - 2026
DA  - 2026/11/17
JO  - Frontiers in Neuroscience
DO  - 10.3389/fnins.2026.1992412
UR  - https://www.frontiersin.org/articles/10.3389/fnins.2026.1992412
AB  - This study evaluates the performance of a fully integrated in-ear EEG device by comparing it with simultaneous clinical-grade scalp EEG recordings in 29 healthy adults. The analysis focused on two electrophysiological markers: resting-state alpha activity (8–12 Hz) and auditory steady-state responses (ASSRs). ASSRs were tested using both single-frequency stimulation (40 Hz and 80 Hz) and more complex multi-frequency chirp configurations. A significant alpha peak was detected in the in-ear recordings of 15 of 29 participants (52%), compared with 83–100% for the scalp derivations. In-ear alpha peak power and signal-to-noise ratio were significantly correlated with scalp EEG at all six scalp derivations, indicating that the device preserves inter-individual differences in alpha strength despite reduced signal amplitude. The in-ear device recovered the group-level alpha frequency, but agreement with scalp EEG for individual alpha frequency (IAF) was limited. ASSR performance depended strongly on the stimulation paradigm. In-ear ASSR detection rates were lower than scalp rates at both modulation frequencies; at the two highest intensities, they reached 39–44% of the rate of the ipsilateral temporal scalp derivations at 40 Hz and 74–75% at 80 Hz. More complex multi-frequency stimulation resulted in a marked reduction in detection performance in both recording modalities. Overall, in a short controlled laboratory session, the fully integrated in-ear EEG system captured resting-state alpha activity and detected auditory steady-state responses under simple stimulation conditions in a subset of participants.
SN  - 1662-453X
ER  -