Skip to content
DraconiticResearch
Search Sources API
186,086 studies31 sourcesUpdated 52 min ago
PreprintarXiv licencearXiv

Temperature distribution measurement on three-phase contact line in liquid nitrogen using two-color temperature-sensitive paint

Abstract

Cryogenic phase-change phenomena play an important role in a wide range of engineering applications, including cryogenic cooling systems, superconducting technologies, and space propulsion systems. In particular, the three-phase contact line is recognized as a key region governing evaporation and heat transfer. However, direct measurements of temperature distributions near cryogenic three-phase contact lines remain limited because conventional infrared thermography becomes increasingly difficult at extremely low temperatures. In this study, a two-color temperature-sensitive paint (2C-TSP) technique was applied to visualize the temperature field around a liquid-nitrogen three-phase contact line. A temperature-sensitive dye and a temperature-insensitive reference dye were incorporated into a single coating, enabling robust temperature measurements based on luminescence intensity ratios by compensating for changes in optical intensity caused by refraction and reflection at the liquid-gas interface. Temperature distributions were measured under three heating conditions with heat fluxes of 110, 430, and 900 W/m2. The measured temperature fields revealed a localized temperature minimum at the observed three-phase contact line, suggesting localized cooling associated with phase change. Quantitative analysis showed that the average temperature in the liquid region remained nearly constant, whereas the temperature in the gas region increased with increasing heat flux. These observations reveal a non-uniform thermal structure around the cryogenic three-phase contact line. The present results demonstrate that 2C-TSP is a promising technique for direct visualization of temperature fields around cryogenic three-phase contact lines and provides new insights into phase-change phenomena in liquid nitrogen.

Versions

Related

  1. Determination of fundamental properties of nitrogen from first principles. III. Temperature and frequency dependence of the molecular polarizability and magnetic susceptibility
    Jakub Lang, Giovanni Garberoglio, Michał Przybytek +1
    arXivPreprintCC BY 4.0Full textPhysical chemistryCondensed matterarXiv
  2. Improvement of Electron Cyclotron Emission Radiometer Towards Real-Time Temperature Measurement in the WEST tokamak
    Kuan-Wen Chen, S Mazzi, G Miglionico +13
    HALPreprintCC BY-NC 4.0Full textPlasma physicsHAL
  3. Dual-Band Mid-Infrared Imaging for Measurement of Fuel Concentration and Temperature in a Supersonic Cavity
    Loren C. Hahn, Erik L. Braun, Brendan J. McGann +2
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationFluid dynamicsarXiv
  4. Reconstruction of the superstatistical temperature distribution from single-particle kinetic energies
    Sergio Davis
    arXivPreprintCC BY 4.0Full textStatistical & nonlinear physicsarXiv
  5. Thomson Scattering Measurement of 1 keV Electron Temperature on Lawson Machine 26
    P. Carle, S. Edwards, X. Feng +11
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationarXiv
BibTeX
@misc{fujiwara2026temperature,
  title = {{Temperature distribution measurement on three-phase contact line in liquid nitrogen using two-color temperature-sensitive paint}},
  author = {Shione Fujiwara and Yasuhiro Egami and Osamu Kawanami and Yu Matsuda},
  howpublished = {arXiv},
  year = {2026},
  month = jun,
  doi = {10.48550/arxiv.2606.24533},
  eprint = {2606.24533},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2606.24533},
}
RIS
TY  - UNPB
TI  - Temperature distribution measurement on three-phase contact line in liquid nitrogen using two-color temperature-sensitive paint
AU  - Shione Fujiwara
AU  - Yasuhiro Egami
AU  - Osamu Kawanami
AU  - Yu Matsuda
PY  - 2026
DA  - 2026/06/23
PB  - arXiv
DO  - 10.48550/arxiv.2606.24533
UR  - https://arxiv.org/abs/2606.24533
AB  - Cryogenic phase-change phenomena play an important role in a wide range of engineering applications, including cryogenic cooling systems, superconducting technologies, and space propulsion systems. In particular, the three-phase contact line is recognized as a key region governing evaporation and heat transfer. However, direct measurements of temperature distributions near cryogenic three-phase contact lines remain limited because conventional infrared thermography becomes increasingly difficult at extremely low temperatures. In this study, a two-color temperature-sensitive paint (2C-TSP) technique was applied to visualize the temperature field around a liquid-nitrogen three-phase contact line. A temperature-sensitive dye and a temperature-insensitive reference dye were incorporated into a single coating, enabling robust temperature measurements based on luminescence intensity ratios by compensating for changes in optical intensity caused by refraction and reflection at the liquid-gas interface. Temperature distributions were measured under three heating conditions with heat fluxes of 110, 430, and 900 W/m2. The measured temperature fields revealed a localized temperature minimum at the observed three-phase contact line, suggesting localized cooling associated with phase change. Quantitative analysis showed that the average temperature in the liquid region remained nearly constant, whereas the temperature in the gas region increased with increasing heat flux. These observations reveal a non-uniform thermal structure around the cryogenic three-phase contact line. The present results demonstrate that 2C-TSP is a promising technique for direct visualization of temperature fields around cryogenic three-phase contact lines and provides new insights into phase-change phenomena in liquid nitrogen.
ER  -