Microbeam radiotherapy - clinical and dosimetric investigation of a first clinical application.

6 affiliations
  1. 1Department of Radiation Oncology, TUM School of Medicine and Health, TUM University Hospital, Technical University of Munich, 81675, Munich, Germany. [email protected].
  2. 2Institute for Advanced Study, Technical University of Munich (TUM), Garching, Germany. [email protected].
  3. 3Partner Site Munich, German Consortium for Translational Cancer Research (DKTK), 80336, Munich, Germany. [email protected].
  4. 4Department of Radiation Oncology, TUM School of Medicine and Health, TUM University Hospital, Technical University of Munich, 81675, Munich, Germany.
  5. 5CollimateHealth GmbH, Haager Str. 5, Munich, Germany.
  6. 6Partner Site Munich, German Consortium for Translational Cancer Research (DKTK), 80336, Munich, Germany.

Abstract

Background

Microbeam Radiotherapy (MRT) is an emerging radiotherapy technique which delivers spatially fractionated beams on a micrometre scale. In preclinical studies MRT has demonstrated superior normal tissue sparing compared to conventional radiotherapy while maintaining tumour control. However, MRT has traditionally been achievable only at large synchrotron facilities which has impeded clinical translation. The development of a compact line-focus X-ray tube (LFXT) provides a pathway for clinical MRT, but identification of clinically and dosimetrically suitable patient scenarios is required for first-in-human trials.Materials and methods

Potentially eligible patients were selected from our patient cohort based on clinical criteria including palliative treatment indication, superficial tumour location, reproducible and safe positioning, minimal interference from other therapies, and expected benefit from MRT. Three-dimensional forward treatment planning was performed in Eclipse using gantry rotations, collimator positioning, and conformal masks to treat the clinical target volume (CTV). Dose was calculated in Eclipse using a custom Monte Carlo-based hybrid algorithm adapted for the compact LFXT system with a 300 kVp beam and an eccentric focal spot. A single-fraction equivalent uniform doses (EUD) of 3 Gy was prescribed to the target volume. Dose distributions were analysed using dose-volume histograms (DVHs), peak and valley depth dose profiles, and peak-to-valley dose ratios (PVDRs).Results

Selected cases included primary lymphoma, squamous cell carcinoma, and superficial soft tissue metastases. Dosimetric analysis under exploratory assumptions demonstrated dosimetrically feasible treatment plans with optimal target coverage and organ-at-risk (OAR) sparing for gluteal, nuchal, and inguinal tumours. Maximum OAR doses remained below 8.5 Gy, except in bone or overlapping high-density regions. The mean peak and valley dose across all plans was 57.2 Gy and 3.9 Gy, respectively, with a mean PVDR of 15.4. Dose inhomogeneities were observed due to tissue heterogeneity, kilovoltage beam interactions, and a limited range of suitable gantry angles. Tumours in anatomically complex regions, including those in proximity to OARs or tissue inhomogeneities, showed less favourable trade-offs between target coverage and OAR sparing.Conclusion

This study identifies clinically and dosimetrically suitable scenarios for first-in-human MRT trials, highlighting superficial tumours as optimal initial indications. While peak, valley, and PVDR values align with preclinical evidence, their clinical significance remains uncertain. Careful, safety-driven dose escalation studies will be required to establish a foundation for responsible and effective clinical application of MRT in early-phase clinical trials.

Related

  1. Exploratory machine-learning evaluation of clinical and dosimetric features in late prostate radiotherapy toxicity.
    Karl Jordan, Christopher J Talbot, John D Kelleher +2
    Clinical and translational radiation oncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMC
  2. Hypofractionated and conventionally fractionated radiotherapy for synchronous bilateral breast cancer: clinical and dosimetric outcomes
    Bahar Cepni, Line Hoeltgen, David Neugebauer +11
    Strahlentherapie Und OnkologiePeer-reviewedCC BY 4.0Full textApplied physics & instrumentationPMC
  3. Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
    Alaa AbdAllah, wafaa mohamed, Amani Saber +1
    Minia Journal of Medical ResearchPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  4. Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy
    Srikanth Guduru, Rohith Singareddy, N. V. N. Madhusudhana Sresty +2
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  5. Optimising electron beam 6 MeV radiotherapy: field-size-dependent dosimetric impact of perforated thermoplastic immobilisation masks.
    Mohammed Rezzoug, Yassine Oulhouq, Omar Hamzaoui +3
    Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation OncologyPeer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMC
BibTeX
@article{kraus2026microbeam,
  title = {{Microbeam radiotherapy - clinical and dosimetric investigation of a first clinical application.}},
  author = {Kim Melanie Kraus and Liam R Day and Jan J Wilkens and Stephanie E Combs and Stefan Bartzsch},
  journal = {Radiation oncology (London, England)},
  year = {2026},
  month = oct,
  doi = {10.1186/s13014-026-02946-2},
  url = {https://europepmc.org/article/MED/42920150},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Microbeam radiotherapy - clinical and dosimetric investigation of a first clinical application.
AU  - Kim Melanie Kraus
AU  - Liam R Day
AU  - Jan J Wilkens
AU  - Stephanie E Combs
AU  - Stefan Bartzsch
PY  - 2026
DA  - 2026/10/23
JO  - Radiation oncology (London, England)
DO  - 10.1186/s13014-026-02946-2
UR  - https://europepmc.org/article/MED/42920150
AB  - Background  Microbeam Radiotherapy (MRT) is an emerging radiotherapy technique which delivers spatially fractionated beams on a micrometre scale. In preclinical studies MRT has demonstrated superior normal tissue sparing compared to conventional radiotherapy while maintaining tumour control. However, MRT has traditionally been achievable only at large synchrotron facilities which has impeded clinical translation. The development of a compact line-focus X-ray tube (LFXT) provides a pathway for clinical MRT, but identification of clinically and dosimetrically suitable patient scenarios is required for first-in-human trials.Materials and methods  Potentially eligible patients were selected from our patient cohort based on clinical criteria including palliative treatment indication, superficial tumour location, reproducible and safe positioning, minimal interference from other therapies, and expected benefit from MRT. Three-dimensional forward treatment planning was performed in Eclipse using gantry rotations, collimator positioning, and conformal masks to treat the clinical target volume (CTV). Dose was calculated in Eclipse using a custom Monte Carlo-based hybrid algorithm adapted for the compact LFXT system with a 300 kVp beam and an eccentric focal spot. A single-fraction equivalent uniform doses (EUD) of 3 Gy was prescribed to the target volume. Dose distributions were analysed using dose-volume histograms (DVHs), peak and valley depth dose profiles, and peak-to-valley dose ratios (PVDRs).Results  Selected cases included primary lymphoma, squamous cell carcinoma, and superficial soft tissue metastases. Dosimetric analysis under exploratory assumptions demonstrated dosimetrically feasible treatment plans with optimal target coverage and organ-at-risk (OAR) sparing for gluteal, nuchal, and inguinal tumours. Maximum OAR doses remained below 8.5 Gy, except in bone or overlapping high-density regions. The mean peak and valley dose across all plans was 57.2 Gy and 3.9 Gy, respectively, with a mean PVDR of 15.4. Dose inhomogeneities were observed due to tissue heterogeneity, kilovoltage beam interactions, and a limited range of suitable gantry angles. Tumours in anatomically complex regions, including those in proximity to OARs or tissue inhomogeneities, showed less favourable trade-offs between target coverage and OAR sparing.Conclusion  This study identifies clinically and dosimetrically suitable scenarios for first-in-human MRT trials, highlighting superficial tumours as optimal initial indications. While peak, valley, and PVDR values align with preclinical evidence, their clinical significance remains uncertain. Careful, safety-driven dose escalation studies will be required to establish a foundation for responsible and effective clinical application of MRT in early-phase clinical trials.
SN  - 1748-717X
ER  -