Skip to content
DraconiticResearch
Search Sources API
186,625 studies31 sourcesUpdated 45 min ago
Peer-reviewedCC BY-NC-ND 4.0In Vivo

Quantifying Patient Setup Error in Total Body Irradiation With Megavoltage Computed Tomography-guided Helical Tomotherapy

  1. 1Department of Radiology, Toranomon Hospital, Tokyo, Japan
  2. 2Department of Radiological Science, Graduate School of Human Health Science, Tokyo Metropolitan University, Tokyo, Japan
  3. 3Department of Radiation Oncology, Toranomon Hospital, Tokyo, Japan

Abstract

Background/Aim: In helical tomotherapy (HT)-based total body irradiation (TBI), geometric accuracy is essential because intensity-modulated dose delivery relies on steep dose gradients. However, residual site-specific setup errors (SEs) after routine image guidance have not been fully characterized. This study quantified residual translational SEs after megavoltage computed tomography (MVCT)-guided global bony registration and derived landmark-specific planning target volume (PTV) and planning organ-at-risk volume (PRV) margins.

Patients and Methods: Twenty consecutive patients who underwent HT-based TBI as conditioning for allogeneic hematopoietic stem cell transplantation were retrospectively analyzed. A total dose of 12.0 Gy in four fractions was delivered using separate head-first and feet-first plans. After routine MVCT-guided registration, residual translational SEs were manually measured in the left-right, superior-inferior, and anterior-posterior directions at predefined anatomical landmarks: mandible, bilateral shoulders, pelvis, bilateral knees, bilateral heels, lung, liver, and bilateral kidneys. Systematic and random errors were calculated for each landmark, and PTV and PRV margins were estimated using modified margin recipes.

Results: Eighty fractions were analyzed. The mandible and lung showed high reproducibility, with residual SEs within 5.0 mm in all directions. In contrast, the shoulders showed the largest PTV-related uncertainty, with estimated PTV margins exceeding 10.0 mm in the superior-inferior and anterior-posterior directions. The liver and kidneys showed marked organ-related uncertainty, particularly in the superior-inferior direction; PRV margins reached 9.2 mm for the liver and up to 9.8 mm for the kidneys.

Conclusion: Residual SEs in MVCT-guided HT-based TBI were strongly site-dependent. Larger uncertainties in the shoulders, liver, and kidneys indicate that site-specific PTV and PRV margins should be considered rather than applying uniform margins across the whole body.

Related

  1. Full-field fluorescence computed tomography (F3CT) using a calibrated virtual cone-beam pinhole geometry
    Thomas Zillhardt, Yunhui Chen, Alexander Rack +4
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationBiological & medical physicsarXiv
  2. Neural-network-based material identification in photon-counting computed tomography using region-of-interest spectral features
    A. Miadzvetski, V. Rozhkov, R. Sotenskii +2
    arXivPreprintCC BY-NC-ND 4.0Full textApplied physics & instrumentationarXiv
  3. Computed Tomography Reconstruction Algorithm Using Markov Random Field Model
    Taiga Shimomiya, Taichi Kusumi, Masayuki Uesugi +4
    arXivPreprintarXiv licenceFull textBiological & medical physicsComputational physicsarXiv
  4. Towards 3D fully randomized frequency-domain reconstruction of the speed of sound in breast ultrasound computed tomography
    Luca A. Forte
    arXivPreprintarXiv licenceFull textBiological & medical physicsComputational physicsarXiv
  5. Contrast-enhanced micro-computed tomography visualization of adhesively bonded CFRP/aluminum tubular joints
    John De Vos, Sascha Senck, Iván Josipovic +2
    Nanoscale AdvancesPeer-reviewedCC BY-NC 3.0Full textApplied physics & instrumentationPMC
BibTeX
@article{yamashita2026quantifying,
  title = {{Quantifying Patient Setup Error in Total Body Irradiation With Megavoltage Computed Tomography-guided Helical Tomotherapy}},
  author = {RYUTARO YAMASHITA and SHINGO OHIRA and YOHEI UTENA and KENTARO SUZUKI and KAZUKI SUZUKI and NAOYA KAMIYAMA and LICHT TOMINAGA and ISAO KURITA and MASAKATSU TANO and TAKUYO KOZUKA},
  journal = {In Vivo},
  year = {2026},
  month = oct,
  doi = {10.21873/invivo.14517},
  url = {https://doi.org/10.21873/invivo.14517},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Quantifying Patient Setup Error in Total Body Irradiation With Megavoltage Computed Tomography-guided Helical Tomotherapy
AU  - RYUTARO YAMASHITA
AU  - SHINGO OHIRA
AU  - YOHEI UTENA
AU  - KENTARO SUZUKI
AU  - KAZUKI SUZUKI
AU  - NAOYA KAMIYAMA
AU  - LICHT TOMINAGA
AU  - ISAO KURITA
AU  - MASAKATSU TANO
AU  - TAKUYO KOZUKA
PY  - 2026
DA  - 2026/10/29
JO  - In Vivo
DO  - 10.21873/invivo.14517
UR  - https://doi.org/10.21873/invivo.14517
AB  - Background/Aim: In helical tomotherapy (HT)-based total body irradiation (TBI), geometric accuracy is essential because intensity-modulated dose delivery relies on steep dose gradients. However, residual site-specific setup errors (SEs) after routine image guidance have not been fully characterized. This study quantified residual translational SEs after megavoltage computed tomography (MVCT)-guided global bony registration and derived landmark-specific planning target volume (PTV) and planning organ-at-risk volume (PRV) margins.  Patients and Methods: Twenty consecutive patients who underwent HT-based TBI as conditioning for allogeneic hematopoietic stem cell transplantation were retrospectively analyzed. A total dose of 12.0 Gy in four fractions was delivered using separate head-first and feet-first plans. After routine MVCT-guided registration, residual translational SEs were manually measured in the left-right, superior-inferior, and anterior-posterior directions at predefined anatomical landmarks: mandible, bilateral shoulders, pelvis, bilateral knees, bilateral heels, lung, liver, and bilateral kidneys. Systematic and random errors were calculated for each landmark, and PTV and PRV margins were estimated using modified margin recipes.  Results: Eighty fractions were analyzed. The mandible and lung showed high reproducibility, with residual SEs within 5.0 mm in all directions. In contrast, the shoulders showed the largest PTV-related uncertainty, with estimated PTV margins exceeding 10.0 mm in the superior-inferior and anterior-posterior directions. The liver and kidneys showed marked organ-related uncertainty, particularly in the superior-inferior direction; PRV margins reached 9.2 mm for the liver and up to 9.8 mm for the kidneys.  Conclusion: Residual SEs in MVCT-guided HT-based TBI were strongly site-dependent. Larger uncertainties in the shoulders, liver, and kidneys indicate that site-specific PTV and PRV margins should be considered rather than applying uniform margins across the whole body.
SN  - 0258-851X
SN  - 1791-7549
ER  -