Airborne and Surface Bacteria in ORs: Integration of ASHRAE-Compliant Ventilation and Active UV-C Air Treatment.

Abstract

Bacteria in ORs increase surgical site infection risk. The American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 170 defines OR ventilation standards, but the added benefit of in-room supplemental ultraviolet C air treatment remains uncertain. We compared bacterial counts before and after installing active ultraviolet C air treatment in an OR with Standard 170-compliant ventilation, using a similar OR as a control with Standard 170-compliant ventilation alone. After installation, the intervention OR showed 80% fewer airborne bacteria and 61% fewer settled surface bacteria. The control OR showed a 219% increase in airborne colony-forming units per cubic meter and a 24% increase in settled surface bacteria over the same period, reflecting potential confounders. Although the intervention was associated with lower bacterial levels in two assays, more evidence is needed given the limited number of ORs tested and the variation in the control OR.

Related

  1. An Exploratory Comparison of Indoor Air Quality and Culturable Airborne Microbial Concentrations Among Hospital Waiting Areas With Different Ventilation Conditions in Northern Thailand
    Pantitcha Thanatrakolsri, Natnicha Tammawong, Sasiticha Arworn +3
    Environmental Health InsightsPeer-reviewedCC BYFull textPharmacology & toxicologyDOAJ
  2. Particulate Matter as a Carrier for Airborne Bacteria: An Integrated Assessment of Chemical and Microbiological Air Quality in Urban Nagpur, India
    Tanvir Arfin, Sakshi Verma
    Innovation of Chemistry & Materials for SustainabilityPeer-reviewedCC BYFull textPharmacology & toxicologyDOAJ
  3. Beyond smoke: culturable airborne bacteria associated with informal waste burning in peri-urban South Africa.
    Boitemogelo O Kwakwa, Shalin Bidassey-Manilal, Natasha Naidoo +1
    Frontiers in public healthPeer-reviewedCC BYFull textPharmacology & toxicologyEurope PMCCrossref
  4. Mathematical Analysis of Multi-Route Tuberculosis Transmission with Airborne Environmental Reservoirs and Treatment Failure
    Nada A. Almuallem
    MathematicsPeer-reviewedCC BY 4.0Epidemiology & public healthCrossref
  5. Advances in the management of pneumonia caused by drug-resistant bacteria: from antimicrobial optimisation to integrated treatment adaptation
    Zhenping Wu, Lingtong Huang, Lianlian Fu +5
    eBioMedicinePeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossrefPMC
BibTeX
@article{lee2026airborne,
  title = {{Airborne and Surface Bacteria in ORs: Integration of ASHRAE-Compliant Ventilation and Active UV-C Air Treatment.}},
  author = {Linda D Lee and Isabelle Clark and Matthew Toldy and Conor Donnelly and Haley Hatfield and Kristen Metzger and Kellee Necaise and L Michelle Cleveland-Hall and Sarah Bomgaars and Lauren Nemeth and Jennifer McNary Smith and Russell N Olmsted},
  journal = {AORN journal},
  year = {2026},
  month = oct,
  doi = {10.1002/aorn.70176},
  url = {https://europepmc.org/article/MED/42949577},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Airborne and Surface Bacteria in ORs: Integration of ASHRAE-Compliant Ventilation and Active UV-C Air Treatment.
AU  - Linda D Lee
AU  - Isabelle Clark
AU  - Matthew Toldy
AU  - Conor Donnelly
AU  - Haley Hatfield
AU  - Kristen Metzger
AU  - Kellee Necaise
AU  - L Michelle Cleveland-Hall
AU  - Sarah Bomgaars
AU  - Lauren Nemeth
AU  - Jennifer McNary Smith
AU  - Russell N Olmsted
PY  - 2026
DA  - 2026/10/28
JO  - AORN journal
DO  - 10.1002/aorn.70176
UR  - https://europepmc.org/article/MED/42949577
AB  - Bacteria in ORs increase surgical site infection risk. The American Society of Heating, Refrigerating and Air-Conditioning Engineers Standard 170 defines OR ventilation standards, but the added benefit of in-room supplemental ultraviolet C air treatment remains uncertain. We compared bacterial counts before and after installing active ultraviolet C air treatment in an OR with Standard 170-compliant ventilation, using a similar OR as a control with Standard 170-compliant ventilation alone. After installation, the intervention OR showed 80% fewer airborne bacteria and 61% fewer settled surface bacteria. The control OR showed a 219% increase in airborne colony-forming units per cubic meter and a 24% increase in settled surface bacteria over the same period, reflecting potential confounders. Although the intervention was associated with lower bacterial levels in two assays, more evidence is needed given the limited number of ORs tested and the variation in the control OR.
SN  - 0001-2092
SN  - 1878-0369
ER  -