Pneumoconiosis in Two Sibling Rush Mat Workers Exposed to Clay Dye ‘IGUSA‐SENDO’ Diagnosed by Transbronchial Lung Cryobiopsy
6 affiliations
- 1Division of Respirology, Neurology and Rheumatology, Department of Medicine Kurume University School of Medicine Fukuoka Japan
- 2Department of Pathology Informatics Nagasaki University Graduate School of Biomedical Sciences Nagasaki Japan
- 3Department of Respirology NHO Kyushu Medical Center Fukuoka Japan
- 4Department of Radiology Kurume University School of Medicine Fukuoka Japan
- 5Department of Pathology Kagoshima City Hospital Kagoshima Japan
- 6Advanced Imaging Research Center, Kurume University School of Medicine Fukuoka Japan
Abstract
Rush dust (Igusa‐sendo) pneumoconiosis is a rare occupational pneumoconiosis caused by the long‐term inhalation of sendo dust adhering to the igusa rush during traditional tatami‐omote manufacturing. We report two cases of siblings diagnosed by transbronchial lung cryobiopsy (TBLC). A 62‐year‐old woman and her 57‐year‐old brother worked for many years in traditional tatami‐omote manufacturing at different workplaces. Both patients presented with cough, and chest computed tomography (CT) revealed diffuse bilateral centrilobular nodules, ground‐glass opacities, and high‐attenuation mediastinal and hilar lymphadenopathies. TBLC specimens showed focal nodular fibrosis with dust deposition, and scanning electron microscopy with energy‐dispersive X‐ray spectroscopy demonstrated silicon and aluminium consistent with aluminosilicate‐containing mineral dust. These findings, together with long‐term occupational exposure, led to the diagnosis of rush dust pneumoconiosis. This disease should be considered in patients with a long history of rush mat manufacturing. Therefore, TBLC might be useful for pathological confirmation.
Related
- Eosinophilic Bronchiolitis Diagnosed by a Transbronchial Lung Cryobiopsy and Successfully Treated with Biologic Agents: A Report of Two Cases and Literature Review
- Pulmonary Hamartoma Diagnosed by Transbronchial Mediastinal Cryobiopsy Additional to Needle Aspiration: A Case Report
- Case Report: Adult-onset idiopathic pulmonary hemosiderosis diagnosed by transbronchial lung cryobiopsy
- Dual-scope method for hemostasis during transbronchial lung cryobiopsy : A two-patient case report
- A Case of Recurrent COVID-19 Pneumonia Following Rituximab Therapy: Treatment Informed by a Serial Transbronchial Lung Cryobiopsy, BALF SARS-CoV-2 PCR, and the Clinical Course
BibTeX
@article{takaki2026pneumoconiosis,
title = {{Pneumoconiosis in Two Sibling Rush Mat Workers Exposed to Clay Dye ‘IGUSA‐SENDO’ Diagnosed by Transbronchial Lung Cryobiopsy}},
author = {Reiko Takaki and Yoshiaki Zaizen and Shinsei Ota and Riho Nakano and Yutaro Kono and Sakiko Sumita and Seiji Kimura and Masayuki Watanabe and Midori Zaizen and Tomonori Chikasue and Kazuhiro Tabata and Masaki Okamoto and Keisuke Ohta and Masaki Tominaga and Kiminori Fujimoto and Junya Fukuoka and Tomoaki Hoshino},
journal = {Respirology Case Reports},
year = {2026},
month = nov,
doi = {10.1002/rcr2.70808},
url = {https://doi.org/10.1002/rcr2.70808},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Pneumoconiosis in Two Sibling Rush Mat Workers Exposed to Clay Dye ‘IGUSA‐SENDO’ Diagnosed by Transbronchial Lung Cryobiopsy
AU - Reiko Takaki
AU - Yoshiaki Zaizen
AU - Shinsei Ota
AU - Riho Nakano
AU - Yutaro Kono
AU - Sakiko Sumita
AU - Seiji Kimura
AU - Masayuki Watanabe
AU - Midori Zaizen
AU - Tomonori Chikasue
AU - Kazuhiro Tabata
AU - Masaki Okamoto
AU - Keisuke Ohta
AU - Masaki Tominaga
AU - Kiminori Fujimoto
AU - Junya Fukuoka
AU - Tomoaki Hoshino
PY - 2026
DA - 2026/11/16
JO - Respirology Case Reports
DO - 10.1002/rcr2.70808
UR - https://doi.org/10.1002/rcr2.70808
AB - Rush dust (Igusa‐sendo) pneumoconiosis is a rare occupational pneumoconiosis caused by the long‐term inhalation of sendo dust adhering to the igusa rush during traditional tatami‐omote manufacturing. We report two cases of siblings diagnosed by transbronchial lung cryobiopsy (TBLC). A 62‐year‐old woman and her 57‐year‐old brother worked for many years in traditional tatami‐omote manufacturing at different workplaces. Both patients presented with cough, and chest computed tomography (CT) revealed diffuse bilateral centrilobular nodules, ground‐glass opacities, and high‐attenuation mediastinal and hilar lymphadenopathies. TBLC specimens showed focal nodular fibrosis with dust deposition, and scanning electron microscopy with energy‐dispersive X‐ray spectroscopy demonstrated silicon and aluminium consistent with aluminosilicate‐containing mineral dust. These findings, together with long‐term occupational exposure, led to the diagnosis of rush dust pneumoconiosis. This disease should be considered in patients with a long history of rush mat manufacturing. Therefore, TBLC might be useful for pathological confirmation.
SN - 2051-3380
ER -