Skip to content
DraconiticResearch
Search Sources API
186,546 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BY 4.0Frontiers in Neuroscience

Inter-subject receive-template substitution for quantitative brain water content mapping at 3 T: a leave-one-out evaluation

  1. 1Institute of Neuroscience and Medicine 4, Medical Imaging Physics, Forschungszentrum Jülich
  2. 2Department of Neurology, RWTH Aachen University
  3. 3JARA–BRAIN – Translational Medicine

Abstract

Introduction: To evaluate a configuration-specific inter-subject receive template as an alternative to participant-specific receive referencing within the evaluated 3 T scanner configuration.

Methods: Datasets from twenty-five healthy subjects were analyzed using a strict leave-one-participant-out method. Each degree-3 template used the other 24 participants. Arm E used a participant-specific effective relative receive divisor; Arm T used the held-out template. Both arms underwent independent, identically defined residual calibration, including a local intercept (C ₀ ), its spatially regularized field (μ), and the mean-normalized form used downstream (μ). This was followed by ventricular-CSF calibration. Primary outcomes were participant-level median quantitative water content (qWC) in white and gray matter; whole brain was secondary. Paired bias, mean absolute error (MAE), Bland–Altman limits, Pearson r, and Lin concordance correlation coefficient (CCC) were calculated.

Results: Mean relative receive-template mismatch was 2.273% (standard deviation (SD), 0.568%; range, 1.431%–3.615%). Mean Arm T minus Arm E differences were −0.04 percentage units (p.u.; dimensionless water fraction relative to pure water = 100 p.u.) in white matter and −0.17 p.u. in gray matter; MAE was 0.17 and 0.22 p.u., and CCC was 0.991 and 0.989, respectively. Whole-brain bias was −0.12 p.u. (MAE, 0.19 p.u.; CCC, 0.993). Bland–Altman widths were below 1 p.u. Exploratory associations between global mismatch and qWC disagreement were weak; all 95% participant-bootstrap confidence intervals spanned zero.

Discussion: Under symmetric arm-specific calibration, the configuration-specific template produced qWC estimates in close agreement with the participant-specific explicit reference strategy. This internal matched-configuration result supports technical feasibility but does not establish formal equivalence, interchangeability, or external generalization.

Related

  1. [18F]FDG brain PET-MR versus PET/CT in a clinical cohort: intra-subject quantitative comparisons
    Arick Sagel Martinez, Anthime Flaus, Rolf A. Heckemann +5
    Scientific ReportsPeer-reviewedCC BY 4.0Full textMedical imaging & radiologyCrossref
  2. Quantitative Assessment of Postoperative Lumbar Morphology Using Geometric Morphometrics: Within-Subject Changes Following TLIF and Decompression.
    Amit Benady, Owen Zhou, Amit Hadad +7
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. Exploratory evaluation of a CEUS-derived substitution for solid-component measurement in the ADNEX model.
    Manli Wu, Ying Chen, Shuangyu Wu +17
    BMC women's healthPeer-reviewedCC BY-NC-NDFull textObstetrics, gynaecology & paediatricsEurope PMCDOAJ
  4. Quantitative determination of lead in household paints in the gambia and evaluation of potential childhood risks
    J. Saidykhan, M. Ahmed, S. Barton +1
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textPharmacology & toxicologyCrossref
  5. The initial application of RawVisionTM plaque (RVP) quantitative technique in evaluation for carotid plaque vulnerability
    Siqi Cao, Juan Cheng, Xinliang Xu +5
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
BibTeX
@article{abbas2026intersubject,
  title = {{Inter-subject receive-template substitution for quantitative brain water content mapping at 3 T: a leave-one-out evaluation}},
  author = {Zaheer Abbas and Faizan Ullah and Sergo Gegechkori and Wieland A. Worthoff and N. Jon Shah},
  journal = {Frontiers in Neuroscience},
  year = {2026},
  month = oct,
  doi = {10.3389/fnins.2026.1986813},
  url = {https://www.frontiersin.org/articles/10.3389/fnins.2026.1986813/full},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Inter-subject receive-template substitution for quantitative brain water content mapping at 3 T: a leave-one-out evaluation
AU  - Zaheer Abbas
AU  - Faizan Ullah
AU  - Sergo Gegechkori
AU  - Wieland A. Worthoff
AU  - N. Jon Shah
PY  - 2026
DA  - 2026/10/19
JO  - Frontiers in Neuroscience
DO  - 10.3389/fnins.2026.1986813
UR  - https://www.frontiersin.org/articles/10.3389/fnins.2026.1986813/full
AB  - Introduction: To evaluate a configuration-specific inter-subject receive template as an alternative to participant-specific receive referencing within the evaluated 3 T scanner configuration.  Methods: Datasets from twenty-five healthy subjects were analyzed using a strict leave-one-participant-out method. Each degree-3 template used the other 24 participants. Arm E used a participant-specific effective relative receive divisor; Arm T used the held-out template. Both arms underwent independent, identically defined residual calibration, including a local intercept (C ₀ ), its spatially regularized field (μ), and the mean-normalized form used downstream (μ). This was followed by ventricular-CSF calibration. Primary outcomes were participant-level median quantitative water content (qWC) in white and gray matter; whole brain was secondary. Paired bias, mean absolute error (MAE), Bland–Altman limits, Pearson r, and Lin concordance correlation coefficient (CCC) were calculated.  Results: Mean relative receive-template mismatch was 2.273% (standard deviation (SD), 0.568%; range, 1.431%–3.615%). Mean Arm T minus Arm E differences were −0.04 percentage units (p.u.; dimensionless water fraction relative to pure water = 100 p.u.) in white matter and −0.17 p.u. in gray matter; MAE was 0.17 and 0.22 p.u., and CCC was 0.991 and 0.989, respectively. Whole-brain bias was −0.12 p.u. (MAE, 0.19 p.u.; CCC, 0.993). Bland–Altman widths were below 1 p.u. Exploratory associations between global mismatch and qWC disagreement were weak; all 95% participant-bootstrap confidence intervals spanned zero.  Discussion: Under symmetric arm-specific calibration, the configuration-specific template produced qWC estimates in close agreement with the participant-specific explicit reference strategy. This internal matched-configuration result supports technical feasibility but does not establish formal equivalence, interchangeability, or external generalization.
SN  - 1662-453X
SN  - 1662-4548
ER  -