Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 26 min ago
PreprintCC BY 4.0arXiv

Low-Temperature Co-Fired Ceramics for a Sustainable Planar Plasma Jet with Homogeneous Plasma in Large Treatment Areas for Biomedical Applications

Abstract

This study presents a portable planar argon-based plasma jet designed for large-area biomedical applications, with an emphasis on uniform discharge, stability, and safety. The device incorporates interchangeable rear and side inlet gas adapters with restriction plates and channels to equalize gas flow, while electrodes are encapsulated in low-temperature co-fired ceramics to reduce degradation and arcing during repeated operation. Flow simulations were conducted for multiple channel configurations to ensure laminar gas distribution and uniform plasma generation. Device performance and safety were evaluated using the kinPen MED as a reference standard. Electrical characteristics, optical emission, discharge uniformity, temperature, gas velocity, ozone generation, UV irradiance, and leakage current were systematically measured. The plasma exhibited stable voltage, current, and power after an initial warm-up period. Temperatures stabilized within minutes, with the rear-inlet configuration demonstrating lower operating temperatures due to higher outlet gas velocity. Ozone levels remained below established safety limits, while UV exposure constrained allowable treatment times. Leakage current decreased with increasing distance and approached safety thresholds at short separations. These results demonstrate that the proposed planar plasma jet provides stable, uniform plasma delivery while meeting key safety requirements, supporting its potential for clinical and biomedical use.

Related

  1. From Solid-State Spin Defects to Fluorescent Proteins: A Perspective on Quantum Optical Sensing Platforms for Biomedical Applications
    Jyotiprakash Parhi, Ayan Majumder, Kasturi Saha
    arXivPreprintCC BY 4.0Full textOptics & photonicsQuantum physics & quantum informationarXiv
  2. Ceramic Materials: From Atomic Bonding and Processing to Microstructure, Functional Properties, and Biomedical Applications
    Jairo Rondon, Juan Valera, Alex Velez Cruz +1
    arXivPreprintCC BY-NC-ND 4.0Full textBiological & medical physicsCondensed matterarXiv
  3. On the statistical theory of strong electrolytes and high-temperature plasmas: New applications of the work by Yukhnovskii and Kelbg II
    W. Ebeling, M. Holovko
    arXivPreprintCC BY 4.0Full textCondensed matterPlasma physicsarXiv
  4. Interacting Boson System at Finite Temperature: The treatment of the lattice calculations
    D. Anchishkin, V. Gnatovskyy, D. Zhuravel +1
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsNuclear physicsarXiv
  5. Kilovolt-class Vertical (011) \b{eta}-Ga2O3 Schottky Diodes for High Voltage and High Temperature Applications
    Emerson J. Hollar, Aaron M. Adams, Nolan S. Hendricks +2
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
BibTeX
@misc{ho2026lowtemperature,
  title = {{Low-Temperature Co-Fired Ceramics for a Sustainable Planar Plasma Jet with Homogeneous Plasma in Large Treatment Areas for Biomedical Applications}},
  author = {Ivan Gomez Ho and Hua-Lin Chen and Cheng-Han Tsai and Jong-Shinn Wu and Yun-Chien Cheng},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2607.26916},
  eprint = {2607.26916},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2607.26916},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Low-Temperature Co-Fired Ceramics for a Sustainable Planar Plasma Jet with Homogeneous Plasma in Large Treatment Areas for Biomedical Applications
AU  - Ivan Gomez Ho
AU  - Hua-Lin Chen
AU  - Cheng-Han Tsai
AU  - Jong-Shinn Wu
AU  - Yun-Chien Cheng
PY  - 2026
DA  - 2026/09/15
PB  - arXiv
DO  - 10.48550/arxiv.2607.26916
UR  - https://arxiv.org/abs/2607.26916
AB  - This study presents a portable planar argon-based plasma jet designed for large-area biomedical applications, with an emphasis on uniform discharge, stability, and safety. The device incorporates interchangeable rear and side inlet gas adapters with restriction plates and channels to equalize gas flow, while electrodes are encapsulated in low-temperature co-fired ceramics to reduce degradation and arcing during repeated operation. Flow simulations were conducted for multiple channel configurations to ensure laminar gas distribution and uniform plasma generation. Device performance and safety were evaluated using the kinPen MED as a reference standard. Electrical characteristics, optical emission, discharge uniformity, temperature, gas velocity, ozone generation, UV irradiance, and leakage current were systematically measured. The plasma exhibited stable voltage, current, and power after an initial warm-up period. Temperatures stabilized within minutes, with the rear-inlet configuration demonstrating lower operating temperatures due to higher outlet gas velocity. Ozone levels remained below established safety limits, while UV exposure constrained allowable treatment times. Leakage current decreased with increasing distance and approached safety thresholds at short separations. These results demonstrate that the proposed planar plasma jet provides stable, uniform plasma delivery while meeting key safety requirements, supporting its potential for clinical and biomedical use.
ER  -