Skip to content
DraconiticResearch
Search Sources API
174,684 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BY-NC-NDReports of Practical Oncology and Radiotherapy

Comparison of different radiotherapy planning techniques in breast cancer using active breathing coordinator

4 affiliations
  1. 1Medical Biophysics, Department of Physics, Faculty of Science, Helwan University, Cairo, Egypt
  2. 2Medical Physics Department, Maadi Military Hospital and Air Force Specialized Hospital, Cairo, Egypt
  3. 3Clinical Oncology Department, Kasr Alainy Center of Clinical Oncology, Cairo University, Cairo, Egypt
  4. 4School of Applied Health Sciences, Badr University in Cairo (BUC), Badr City, Egypt

Abstract

BACKGROUND: To identify the optimal radiotherapy planning technique that provides the best dosimetric outcomes in terms of target coverage and sparing of organs at risk (OAR) when using deep inspiration breath-holding (DIBH) for early left-sided breast cancer treatment. MATERIALS AND METHODS: Thirty patients with early-stage left-sided BC had previously been simulated and treated with DIBH using the active breathing coordinator (ABC) system. Each patient underwent replanning using 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) techniques with a prescription dose of 40.05 Gy over 15 fractions. The planning target volume (PTV) and OARs were evaluated using dose-volume histograms (DVH). Dosimetric parameters [V₉₅, D₉₈, D₅₀, D₂, V₁₀₇, conformity index (CI), homogeneity index (HI)], and OAR metrics for the heart, left anterior descending artery (LAD), lungs, and contralateral breast were analysed statistically. RESULTS: VMAT achieved the best PTV coverage and homogeneity (HI = 0.1). The mean heart dose was lowest for 3DCRT (1.9 Gy) and VMAT (2 Gy), whereas for the LAD VMAT achieved the lowest doses (Dₘₑₐₙ = 5.2 Gy; Dₘₐₓ = 17.3 Gy; p < 0.001). For the ipsilateral lung, 3DCRT offered superior low-dose sparing, while VMAT minimised high-dose exposure. Contralateral lung and breast doses were lowest with 3DCRT. CONCLUSIONS: VMAT offers superior target conformity and cardiac sparing, specifically for the LAD, whereas 3DCRT minimises contralateral organs and low-dose lung exposure. These findings highlight the necessity for personalised treatment, whether the priority is to limit cardiac toxicity or reduce low-dose exposure to the patient.

Related

  1. Comparison of Different Models in Calculation of Tumor Control Probability and Normal Tissue Complication Probability in Breast Cancer Radiotherapy.
    Hayder Tareq, Mahdi Ghorbani, Mohammad Reza Deevband +2
    Journal of medical signals and sensorsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationEurope PMC
  2. Comparative Radiobiological Evaluation of Radiotherapy Techniques Using Equivalent Uniform Dose, Tumor Control Probability, and Normal Tissue Complication Probability in Postmastectomy Breast Cancer
    Garima Gaur, Gurpreet Kaur, Baltej Singh +3
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  3. Dosimetric Comparison of Intensity-Modulated Radiotherapy and Four-Field Three-Dimensional Conformal Radiotherapy in the Management of Prostate Cancer: A Retrospective Dual-Centre Analysis
    Alaa AbdAllah, wafaa mohamed, Amani Saber +1
    Minia Journal of Medical ResearchPeer-reviewedCC BYFull textApplied physics & instrumentationDOAJ
  4. Dosimetric and Treatment Delivery Efficiency Comparison of Two Ring-gantry Linear Accelerator Platforms for Liver Stereotactic Body Radiotherapy
    Srikanth Guduru, Rohith Singareddy, N. V. N. Madhusudhana Sresty +2
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
  5. Dosimetric feasibility of lattice radiotherapy for bulky tumors: a paired VMAT vs. helical tomotherapy comparison - the STRYKE trial
    Mottareale R, Serra M, Pezzulla D +18
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCrossref
BibTeX
@article{farid2026comparison,
  title = {{Comparison of different radiotherapy planning techniques in breast cancer using active breathing coordinator}},
  author = {Yara G. Farid and Mohamed S. Ibrahim and Medhat W. Shafaa and Noha A. Rahmoun and Magdy M. Khalil and Khalid A. Khalil},
  journal = {Reports of Practical Oncology and Radiotherapy},
  year = {2026},
  month = nov,
  doi = {10.5603/rpor.113430},
  url = {https://doi.org/10.5603/rpor.113430},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Comparison of different radiotherapy planning techniques in breast cancer using active breathing coordinator
AU  - Yara G. Farid
AU  - Mohamed S. Ibrahim
AU  - Medhat W. Shafaa
AU  - Noha A. Rahmoun
AU  - Magdy M. Khalil
AU  - Khalid A. Khalil
PY  - 2026
DA  - 2026/11/02
JO  - Reports of Practical Oncology and Radiotherapy
DO  - 10.5603/rpor.113430
UR  - https://doi.org/10.5603/rpor.113430
AB  - BACKGROUND: To identify the optimal radiotherapy planning technique that provides the best dosimetric outcomes in terms of target coverage and sparing of organs at risk (OAR) when using deep inspiration breath-holding (DIBH) for early left-sided breast cancer treatment. MATERIALS AND METHODS: Thirty patients with early-stage left-sided BC had previously been simulated and treated with DIBH using the active breathing coordinator (ABC) system. Each patient underwent replanning using 3D conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated arc therapy (VMAT) techniques with a prescription dose of 40.05 Gy over 15 fractions. The planning target volume (PTV) and OARs were evaluated using dose-volume histograms (DVH). Dosimetric parameters [V₉₅, D₉₈, D₅₀, D₂, V₁₀₇, conformity index (CI), homogeneity index (HI)], and OAR metrics for the heart, left anterior descending artery (LAD), lungs, and contralateral breast were analysed statistically. RESULTS: VMAT achieved the best PTV coverage and homogeneity (HI = 0.1). The mean heart dose was lowest for 3DCRT (1.9 Gy) and VMAT (2 Gy), whereas for the LAD VMAT achieved the lowest doses (Dₘₑₐₙ = 5.2 Gy; Dₘₐₓ = 17.3 Gy; p < 0.001). For the ipsilateral lung, 3DCRT offered superior low-dose sparing, while VMAT minimised high-dose exposure. Contralateral lung and breast doses were lowest with 3DCRT. CONCLUSIONS: VMAT offers superior target conformity and cardiac sparing, specifically for the LAD, whereas 3DCRT minimises contralateral organs and low-dose lung exposure. These findings highlight the necessity for personalised treatment, whether the priority is to limit cardiac toxicity or reduce low-dose exposure to the patient.
SN  - 1507-1367
SN  - 2083-4640
ER  -