The Influence of a Dead-End Filter Membrane on Flow Properties.
- 1Faculty of Mechanical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia.
Abstract
Understanding how a filter membrane affects both the steady flow and pressure transients of intermittent dead-end microfiltration systems is important for their design and operation. This study experimentally investigates the hydraulic resistance and pressure-wave response of a single-membrane filter cartridge using distilled water. The experiments were performed with intact membranes and with membranes removed to assess their contribution relative to the filter housing and connecting elements. The mass flow and pressure drop were measured at different supply pressures, while simultaneous upstream and downstream pressure measurements captured the reproducible transients generated by electropneumatic valve actuation. A frequency analysis and comparisons between experiments with and without flow were used to examine pressure-wave transmission and distinguish flow-related oscillations from those associated with valve actuation and the experimental setup. The estimated resistance of the membrane was approximately 5-15 times that of the filter housing and associated connectors. The membrane attenuated pressure oscillations, introducing an additional transmission delay of approximately 2-3 ms, with the measured signals indicating low-pass filtering behaviour. These findings reveal that the membrane influences both the hydraulic losses and dynamic response of the filtration system, providing experimental data for transient model validation and the assessment of intermittent filtration processes. Some kind of resonance at 10 Hz was observed at a fluid pressure of 1 bar.
Related
- Enhanced Heat Transfer through Density- and Pressure-Driven Flow at Fracture Intersections With Dead-Ends
- The influence of hydrothermal alteration on the frictional properties of andesites: implications for volcano instability and collapse
- Comparative Hydrodynamic Assessment of Twill-Woven Feed Spacers in Flat-Sheet Ultrafiltration Membrane Cassettes: Balancing Hydraulic Resistance and Near-Membrane Flow Enhancement.
- Seasonal influence on post-fire debris flow likelihood after the 2020 Lake Fire
- The influence of moisture ingression on mechanical and vibrational properties of basalt, glass, and hybrid fiber-epoxy composites
BibTeX
@article{bombek2026influence,
title = {{The Influence of a Dead-End Filter Membrane on Flow Properties.}},
author = {Gorazd Bombek and Tilen Jernejc and Luka Lešnik and Matjaž Ramšak},
journal = {Membranes},
year = {2026},
month = nov,
doi = {10.3390/membranes16110393},
url = {https://europepmc.org/article/MED/43083216},
note = {CC BY},
}
RIS
TY - JOUR
TI - The Influence of a Dead-End Filter Membrane on Flow Properties.
AU - Gorazd Bombek
AU - Tilen Jernejc
AU - Luka Lešnik
AU - Matjaž Ramšak
PY - 2026
DA - 2026/11/19
JO - Membranes
DO - 10.3390/membranes16110393
UR - https://europepmc.org/article/MED/43083216
AB - Understanding how a filter membrane affects both the steady flow and pressure transients of intermittent dead-end microfiltration systems is important for their design and operation. This study experimentally investigates the hydraulic resistance and pressure-wave response of a single-membrane filter cartridge using distilled water. The experiments were performed with intact membranes and with membranes removed to assess their contribution relative to the filter housing and connecting elements. The mass flow and pressure drop were measured at different supply pressures, while simultaneous upstream and downstream pressure measurements captured the reproducible transients generated by electropneumatic valve actuation. A frequency analysis and comparisons between experiments with and without flow were used to examine pressure-wave transmission and distinguish flow-related oscillations from those associated with valve actuation and the experimental setup. The estimated resistance of the membrane was approximately 5-15 times that of the filter housing and associated connectors. The membrane attenuated pressure oscillations, introducing an additional transmission delay of approximately 2-3 ms, with the measured signals indicating low-pass filtering behaviour. These findings reveal that the membrane influences both the hydraulic losses and dynamic response of the filtration system, providing experimental data for transient model validation and the assessment of intermittent filtration processes. Some kind of resonance at 10 Hz was observed at a fluid pressure of 1 bar.
SN - 2077-0375
ER -