Comparison of Outcomes of Anterior Chamber Intraocular Lenses with Scleral-fixated Intraocular Lenses: A Systematic Review.
- 1Department of Ophthalmology, Management and Science University, Shah Alam, Malaysia.
- 2Office of Pro-Vice Chancellor, Manipal University College Malaysia, Melaka, Malaysia.
Abstract
The absence of adequate posterior capsule support-whether due to complicated cataract surgery, lens subluxation due to trauma or syndromes, or aphakia due to any other cause-necessitates a suitable intraocular lens (IOL), either an anterior chamber intraocular lens (ACIOL) or a scleral-fixated IOL. The absence of any systematic review in the English literature comparing ACIOL with scleral-fixated IOL prompted this study. We looked for clinical trials (randomized and controlled) comparing the outcomes of ACIOL with scleral-fixated IOLs through various search engines. The searched terms included anterior chamber intraocular lens, scleral-fixated intraocular lens, complicated cataract surgery, and secondary intraocular lens. All patients who had either an ACIOL or scleral-fixated IOL were included. Risk of bias was assessed using the Cochrane Collaboration tools to ascertain the standard and quality of the trials. The outcomes studied were best-corrected visual acuity (BCVA) and intraoperative and postoperative complications. Seven trials were finally selected for analysis. There was no difference in BCVA between ACIOL and scleral-fixated IOL. There was also no difference in terms of complications, including retinal detachment, cystoid macular edema, glaucoma, uveitis, and vitreous prolapse, between the two groups. However, there was a higher chance of vitreous hemorrhage in the scleral-fixated group compared to ACIOL. Both ACIOL and scleral-fixated IOLs appear to be used as safe options in current practice. Further multicenter randomized controlled trials are needed to clarify the benefits of each intervention and strengthen the validity of this review.
Related
- Accuracy of Intraocular Lens Power Calculation Formulas for Two Single-Piece Acrylic IOL Models in Eyes with a Shallow Anterior Chamber.
- Evaluating toric intraocular lens outcomes: A comparison between asymmetric and symmetric bowtie astigmatism
- Comparison of Visual and Ocular Hemodynamic Outcomes Following Trifocal vs Bifocal Intraocular Lens Implantation in Patients With Cataract and Myopia.
- Comparison of clinical outcomes of trifocal versus extended depth of focus intraocular lenses: meta-analysis of randomized controlled trials
- Comparison of outcomes between iris suturing of three piece foldable intraocular lenses and retropupillary iris claw lens implantation techniques.
BibTeX
@article{thevi2026comparison,
title = {{Comparison of Outcomes of Anterior Chamber Intraocular Lenses with Scleral-fixated Intraocular Lenses: A Systematic Review.}},
author = {Thanigasalam Thevi and Adinegara Lutfi Abas},
journal = {Journal of ophthalmic \& vision research},
year = {2026},
month = nov,
doi = {10.18502/jovr.v21.19964},
url = {https://europepmc.org/article/MED/43054345},
note = {CC BY},
}
RIS
TY - JOUR
TI - Comparison of Outcomes of Anterior Chamber Intraocular Lenses with Scleral-fixated Intraocular Lenses: A Systematic Review.
AU - Thanigasalam Thevi
AU - Adinegara Lutfi Abas
PY - 2026
DA - 2026/11/02
JO - Journal of ophthalmic & vision research
DO - 10.18502/jovr.v21.19964
UR - https://europepmc.org/article/MED/43054345
AB - The absence of adequate posterior capsule support-whether due to complicated cataract surgery, lens subluxation due to trauma or syndromes, or aphakia due to any other cause-necessitates a suitable intraocular lens (IOL), either an anterior chamber intraocular lens (ACIOL) or a scleral-fixated IOL. The absence of any systematic review in the English literature comparing ACIOL with scleral-fixated IOL prompted this study. We looked for clinical trials (randomized and controlled) comparing the outcomes of ACIOL with scleral-fixated IOLs through various search engines. The searched terms included anterior chamber intraocular lens, scleral-fixated intraocular lens, complicated cataract surgery, and secondary intraocular lens. All patients who had either an ACIOL or scleral-fixated IOL were included. Risk of bias was assessed using the Cochrane Collaboration tools to ascertain the standard and quality of the trials. The outcomes studied were best-corrected visual acuity (BCVA) and intraoperative and postoperative complications. Seven trials were finally selected for analysis. There was no difference in BCVA between ACIOL and scleral-fixated IOL. There was also no difference in terms of complications, including retinal detachment, cystoid macular edema, glaucoma, uveitis, and vitreous prolapse, between the two groups. However, there was a higher chance of vitreous hemorrhage in the scleral-fixated group compared to ACIOL. Both ACIOL and scleral-fixated IOLs appear to be used as safe options in current practice. Further multicenter randomized controlled trials are needed to clarify the benefits of each intervention and strengthen the validity of this review.
SN - 2008-2010
SN - 2008-322X
ER -