A One-Year In Vivo Study of a Braided Pure Molybdenum Stent: Favorable Biocompatibility and the Critical Challenge of Vascular Biomechanics
- 1Department of Interventional Neuroradiology, Beijing Neurosurgical Institute, Capital Medical University, Beijing, China. Department of Neurosurgery, Beijing T
Abstract
Background: This study aims to evaluate a newly developed biodegradable stent made of pure Molybdenum (Mo) for treating intracranial aneurysms. Unlike traditional permanent metal stents that remain in the body indefinitely, this new device aims to provide temporary support during the healing process and then safely dissolve. Methods: A 30.48 {micro}m braided Mo stent was developed, and its mechanical performance and degradation process were tested in vitro. The stent was then implanted into the arteries of Beagle dogs for a one-year observation period. The study compared these new stents against standard non-degradable stents to monitor safety, structural changes, and the degradation rate within a living organism. Results: The Mo stents demonstrated excellent biocompatibility, showing no signs of organ damage or neurotoxicity, and the material degraded at a rate suitable for aneurysm healing (4.88-5.12 {micro}m/year). However, while the control stents held their shape, the Mo stents showed progressive structural deformation and recoil over time when implanted in the common carotid artery and subclavian artery of Beagle dogs. Conclusion: While this study confirms that Mo is a biocompatible material for stents, it highlights a major challenge in dynamic blood vessels. Future designs must focus on improving the stent's resistance to withstand the repetitive forces found in dynamic blood vessels before it can be considered for clinical use, and intracranial application still requires validation using aneurysm models in the future.
Related
- Long-term in vitro and in vivo biocompatibility evaluation of encapsulation materials for micro-LEDs using a multimodal assessment strategy
- Cydonia oblonga Mill. Whole-Fruit Extract as a Multifunctional Cosmetic Ingredient: Biocompatibility and Concentration-Dependent Effects on the Rheological and Sensory Properties of O/W Emulsions
- Biomechanics-guided computational design of virtual terrestrial vertebrate morphogenesis
- Fucoidan and alginate from brown seaweeds: extraction, structural diversity, biocompatibility, biodegradability, and biomedical applications
- Root responses to mechanical heterogeneity are shaped by pore geometry and root-soil biomechanics
BibTeX
@misc{zhang2026oneyear,
title = {{A One-Year In Vivo Study of a Braided Pure Molybdenum Stent: Favorable Biocompatibility and the Critical Challenge of Vascular Biomechanics}},
author = {F. Zhang and T. Wei and Z. Zheng and J. Yao and W. Jin and S. Wang and W. Liu and B. Cai and Y. Xiang and X. Liu and H. Huang and Y. Zheng and X. Yang and M. Li and Y. Zhang},
howpublished = {bioRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.22.766907},
url = {https://www.biorxiv.org/content/10.64898/2026.11.22.766907v1},
note = {CC BY-NC-ND},
}
RIS
TY - UNPB
TI - A One-Year In Vivo Study of a Braided Pure Molybdenum Stent: Favorable Biocompatibility and the Critical Challenge of Vascular Biomechanics
AU - F. Zhang
AU - T. Wei
AU - Z. Zheng
AU - J. Yao
AU - W. Jin
AU - S. Wang
AU - W. Liu
AU - B. Cai
AU - Y. Xiang
AU - X. Liu
AU - H. Huang
AU - Y. Zheng
AU - X. Yang
AU - M. Li
AU - Y. Zhang
PY - 2026
DA - 2026/11/22
PB - bioRxiv
DO - 10.64898/2026.11.22.766907
UR - https://www.biorxiv.org/content/10.64898/2026.11.22.766907v1
AB - Background: This study aims to evaluate a newly developed biodegradable stent made of pure Molybdenum (Mo) for treating intracranial aneurysms. Unlike traditional permanent metal stents that remain in the body indefinitely, this new device aims to provide temporary support during the healing process and then safely dissolve. Methods: A 30.48 {micro}m braided Mo stent was developed, and its mechanical performance and degradation process were tested in vitro. The stent was then implanted into the arteries of Beagle dogs for a one-year observation period. The study compared these new stents against standard non-degradable stents to monitor safety, structural changes, and the degradation rate within a living organism. Results: The Mo stents demonstrated excellent biocompatibility, showing no signs of organ damage or neurotoxicity, and the material degraded at a rate suitable for aneurysm healing (4.88-5.12 {micro}m/year). However, while the control stents held their shape, the Mo stents showed progressive structural deformation and recoil over time when implanted in the common carotid artery and subclavian artery of Beagle dogs. Conclusion: While this study confirms that Mo is a biocompatible material for stents, it highlights a major challenge in dynamic blood vessels. Future designs must focus on improving the stent's resistance to withstand the repetitive forces found in dynamic blood vessels before it can be considered for clinical use, and intracranial application still requires validation using aneurysm models in the future.
ER -